메뉴 건너뛰기




Volumn 11, Issue 4, 2010, Pages 1572-1579

Reducing the risk of contamination of sterile parenteral products via ready-to-use closure components

Author keywords

component preparation; container closure integrity; plungers; sterilization; stoppers

Indexed keywords

DICHLOROMETHANE; ELASTOMER; ENDOTOXIN;

EID: 78651471804     PISSN: None     EISSN: 15309932     Source Type: Journal    
DOI: 10.1208/s12249-010-9531-8     Document Type: Review
Times cited : (13)

References (21)
  • 5
    • 51949095104 scopus 로고    scopus 로고
    • EudraLex The Rules Governing Medicinal Products in the European Union Annex 1 Manufacture of Sterile Medicinal Products. European Commission February
    • EudraLex The Rules Governing Medicinal Products in the European Union. Volume 4 EU Guidelines to Good Manufacturing Practice Medicinal Products for Human and Veterinary Use. Annex 1 Manufacture of Sterile Medicinal Products. European Commission. 2008: February.
    • (2008) Volume 4 EU Guidelines to Good Manufacturing Practice Medicinal Products for Human and Veterinary Use
  • 7
    • 18744377799 scopus 로고
    • Elastomeric closures for parenterals
    • K.E. Avis H.A. Lieberman L. Lachman (eds). 2 Marcel Dekker New York
    • Smith EJ, Nash RJ. Elastomeric closures for parenterals. In: Avis KE, Lieberman HA, Lachman L, editors. Pharmaceutical dosage forms: parenteral medications volume 1. 2nd ed. New York: Marcel Dekker; 1992. p. 445-507.
    • (1992) Pharmaceutical Dosage Forms: Parenteral Medications Volume 1 , pp. 445-507
    • Smith, E.J.1    Nash, R.J.2
  • 8
    • 0004240247 scopus 로고
    • 2 Robert E. Kreiger Malabar
    • Morton M. Rubber technology. 2nd ed. Malabar: Robert E. Kreiger; 1981.
    • (1981) Rubber Technology
    • Morton, M.1
  • 9
    • 78149293970 scopus 로고    scopus 로고
    • Visualization techniques for XXX affect the interaction between XXX stoppers, PDA
    • P Lam A Stern 2010 Visualization techniques for XXX affect the interaction between XXX stoppers, PDA J Pharm Sci Tech 36 182 187
    • (2010) J Pharm Sci Tech , vol.36 , pp. 182-187
    • Lam, P.1    Stern, A.2
  • 11
    • 35348997080 scopus 로고    scopus 로고
    • Validation of moist heat sterilization processes: Cycle design, development, qualification and ongoing control technical report no. 1
    • JP Agalloco, et al. 2007 Validation of moist heat sterilization processes: cycle design, development, qualification and ongoing control technical report no. 1 J Parenter Sci Technol 61 S-1
    • (2007) J Parenter Sci Technol , vol.61 , pp. 1
    • Agalloco, J.P.1
  • 12
    • 84915892441 scopus 로고
    • Sterilization of Parenterals by Gamma Irradiation Technical Report No. 11
    • Microbiology Sub-committee
    • Microbiology Sub-committee. Sterilization of Parenterals by Gamma Irradiation Technical Report No. 11. Journal of Parenteral Science and Technology. 1988:42,3S.
    • (1988) Journal of Parenteral Science and Technology , vol.42
  • 13
    • 78651492063 scopus 로고    scopus 로고
    • American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization 11137-1:2006/(R)2010-sterilization of health care products-radiation-part 1: requirements for the development, validation and routine control of a sterilization process for medical devices
    • American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization 11137-1:2006/(R)2010-sterilization of health care products-radiation-part 1: requirements for the development, validation and routine control of a sterilization process for medical devices.
  • 14
    • 78651489329 scopus 로고    scopus 로고
    • American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization 11137-2:2006-sterilization of health care products-radiation-part 2: establishing the sterilization dose
    • American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization 11137-2:2006-sterilization of health care products-radiation-part 2: establishing the sterilization dose.
  • 15
    • 78651515665 scopus 로고    scopus 로고
    • American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization 11137-3:2006/(R)2010-sterilization of health care products-radiation-Part 3: guidance on dosimetric aspects
    • American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization 11137-3:2006/(R)2010-sterilization of health care products-radiation-Part 3: guidance on dosimetric aspects.
  • 16
  • 18
    • 84910617781 scopus 로고
    • Effect of gamma irradiation on elastomeric closures technical report No. 16
    • P Kiang, et al. 1992 Effect of gamma irradiation on elastomeric closures technical report No. 16 J Parenter Sci Technol 46 S2
    • (1992) J Parenter Sci Technol , vol.46 , pp. 2
    • Kiang, P.1
  • 20
    • 78651502130 scopus 로고    scopus 로고
    • West Pharmaceutical Services Technical Support Report 2002/012
    • West Pharmaceutical Services. 4432/50 Gray functional study. Technical Support Report 2002/012. 2002.
    • (2002) 4432/50 Gray Functional Study
  • 21
    • 33644991709 scopus 로고    scopus 로고
    • Accessed14Apr2010
    • Sterigenics. Material considerations-irradiation processing. http://www.sterigenics.com/services/medical-sterilization/contract- sterilization/material-consideration--irradiation-processing.pdf. Accessed 14 Apr 2010.
    • Material Considerations-irradiation Processing


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.