Volumn 64, Issue 2, 2010, Pages 182-187

Visualization techniques for assessing design factors that affect the interaction between pharmaceutical vials and stoppers

Author keywords

Pharmaceutical stopper; Pharmaceutical vial; Primary package; Sealing surface

Indexed keywords

ARTICLE; DRUG INDUSTRY; FREEZE DRYING; PACKAGING MATERIAL; SCREENING; DRUG PACKAGING; HUMAN; PHARMACEUTICS;

EID: 78149293970     PISSN: 10797440     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (9)

References (10)
  • 1
    • 78149295463 scopus 로고    scopus 로고
    • note
    • See, for example, the following documents: ISO 8362-1: Injection Containers and Accessories - Part 1: Injection Vials Made of Glass Tubing - 2nd ed.; ISO 8362-2: Injection Containers and Accessories - Part 2: Closure for Injection Vials - 2nd ed.; ISO 8362-4: Injection Containers and Accessories - Part 4: Injection Vials Made of Moulded Glass - 2nd ed.; ISO 8362-5: Injection Containers and Accessories - Part 5: Freeze Drying Closures for Injection Vials - 2nd ed.
  • 2
    • 78149301076 scopus 로고    scopus 로고
    • note
    • The DIN documents are identical to the first-edition ISO documents with the same title.
  • 3
    • 78149320792 scopus 로고    scopus 로고
    • See, for example: GPI Glass finish number 2710: Biological Finish
    • See, for example: GPI Glass finish number 2710: Biological Finish.
  • 4
    • 0023624593 scopus 로고
    • Container/closure integrity of parenteral vials
    • Morton, D. K. Container/closure integrity of parenteral vials. J. Parenter. Sci. Technol. 1987, 41 (5), 145-158.
    • (1987) J. Parenter. Sci. Technol. , vol.41 , Issue.5 , pp. 145-158
    • Morton, D.K.1
  • 5
    • 0024588656 scopus 로고
    • Quantitative and mechanistic measurements of parenteral vial container/closure integrity. Leakage quantitation
    • Morton, D. K.; Lordi, N. G.; Ambrosio, T. J. Quantitative and mechanistic measurements of parenteral vial container/closure integrity. Leakage quantitation. J. Parenter. Sci. Technol. 1989, 43 (2), 88-97.
    • (1989) J. Parenter. Sci. Technol. , vol.43 , Issue.2 , pp. 88-97
    • Morton, D.K.1    Lordi, N.G.2    Ambrosio, T.J.3
  • 6
    • 0024361942 scopus 로고
    • Quantitative and mechanistic measurements of parenteral vial container/closure integrity. Bubble, liquid, and microbial leakage tests
    • Morton, D. K.; Lordi, N. G.; Troutman, L. H.; Ambrosio, T. J. Quantitative and mechanistic measurements of parenteral vial container/closure integrity. Bubble, liquid, and microbial leakage tests. J. Parenter. Sci. Technol. 1989, 43 (3) 104-108.
    • (1989) J. Parenter. Sci. Technol. , vol.43 , Issue.3 , pp. 104-108
    • Morton, D.K.1    Lordi, N.G.2    Troutman, L.H.3    Ambrosio, T.J.4
  • 7
    • 0030657646 scopus 로고    scopus 로고
    • Pharmaceutical container/closure integrity. I: Mass spectrometry-based helium leak rate detection for rubber-stoppered glass vials
    • Kirsch, L. E.; Nguyen, L.; Moeckly, C. S. Pharmaceutical container/closure integrity. I: mass spectrometry-based helium leak rate detection for rubber-stoppered glass vials. PDA J. Pharm. Sci. Technol. 1997, 51 (5), 187-194.
    • (1997) PDA J. Pharm. Sci. Technol. , vol.51 , Issue.5 , pp. 187-194
    • Kirsch, L.E.1    Nguyen, L.2    Moeckly, C.S.3
  • 8
    • 0030724669 scopus 로고    scopus 로고
    • Pharmaceutical container/closure integrity. II: The relationship between microbial ingress and helium leak rate in rubber-stoppered glass vials
    • Kirsch, L. E.; Nguyen, L.; Moeckly, C. S.; Gerth, R. Pharmaceutical container/closure integrity. II: the relationship between microbial ingress and helium leak rate in rubber-stoppered glass vials. PDA J. Pharm. Sci. Technol. 1997, 51 (5), 195-202.
    • (1997) PDA J. Pharm. Sci. Technol. , vol.51 , Issue.5 , pp. 195-202
    • Kirsch, L.E.1    Nguyen, L.2    Moeckly, C.S.3    Gerth, R.4
  • 9
    • 0030707721 scopus 로고    scopus 로고
    • Pharmaceutical container/closure integrity III: Validation of the helium leak rate method for rigid pharmaceutical containers
    • Kirsch, L. E.; Nguyen, L.; Gerth, R. Pharmaceutical container/closure integrity. III: validation of the helium leak rate method for rigid pharmaceutical containers. PDA J. Pharm. Sci. Technol. 1997, 51 (5), 203-207. (Pubitemid 27485883)
    • (1997) PDA Journal of Pharmaceutical Science and Technology , vol.51 , Issue.5 , pp. 203-207
    • Kirsch, L.E.1    Nguyen, L.2    Gerth, R.3
  • 10
    • 0032747732 scopus 로고    scopus 로고
    • Pharmaceutical container/closure integrity. IV: Development of an indirect correlation between vacuum decay leak measurement and microbial ingress
    • Nguyen, L. T.; Muangsiri, W.; Schiere, R.; Guazzo, D. K.; Kirsch, L. E. Pharmaceutical container/closure integrity. IV: development of an indirect correlation between vacuum decay leak measurement and microbial ingress. PDA J. Pharm. Sci. Technol. 1999, 53 (4), 211-216.
    • (1999) PDA J. Pharm. Sci. Technol. , vol.53 , Issue.4 , pp. 211-216
    • Nguyen, L.T.1    Muangsiri, W.2    Schiere, R.3    Guazzo, D.K.4    Kirsch, L.E.5