Volumn 44, Issue 3, 2011, Pages 408-412

Non-invasive determination of coupled motion of the scapula and humerus-An in-vitro validation

Author keywords

Fluoroscopy; Kinematics; Radiostereometric; Shoulder; Validation

Indexed keywords

ACTIVITIES OF DAILY LIVING; CADAVER SPECIMEN; COUPLED MOTIONS; FLUOROSCOPIC IMAGES; FLUOROSCOPIC IMAGING; FLUOROSCOPY; HEALTHY INDIVIDUALS; IN-VITRO; IN-VIVO; MARKERLESS; MODEL-BASED TRACKING; NON-INVASIVE; RADIOSTEREOMETRIC; RADIOSTEREOMETRIC ANALYSIS; SHOULDER; SHOULDER JOINTS; SHOULDER MOTION; SUBMILLIMETERS; TRACKING TECHNIQUES; VALIDATION;

EID: 78651448079     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2010.10.003     Document Type: Article
Times cited : (44)

References (43)
  • 1
    • 0036853008 scopus 로고    scopus 로고
    • Comparison of scapular kinematics between elevation and lowering of the arm in the scapular plane
    • Borstad J.D., Ludewig P.M. Comparison of scapular kinematics between elevation and lowering of the arm in the scapular plane. Clin. Biomech. (Bristol, Avon) 2002, 17(9-10):650-659.
    • (2002) Clin. Biomech. (Bristol, Avon) , vol.17 , Issue.9-10 , pp. 650-659
    • Borstad, J.D.1    Ludewig, P.M.2
  • 2
    • 38749123415 scopus 로고    scopus 로고
    • Measuring dynamic in-vivo glenohumeral joint kinematics: technique and preliminary results
    • Bey M.J., Kline S.K., Zauel R., Lock T.R., Kolowich P.A. Measuring dynamic in-vivo glenohumeral joint kinematics: technique and preliminary results. J. Biomech. 2008, 41(3):711-714.
    • (2008) J. Biomech. , vol.41 , Issue.3 , pp. 711-714
    • Bey, M.J.1    Kline, S.K.2    Zauel, R.3    Lock, T.R.4    Kolowich, P.A.5
  • 3
    • 34347356373 scopus 로고    scopus 로고
    • In vivo measurement of subacromial space width during shoulder elevation: technique and preliminary results in patients following unilateral rotator cuff repair
    • Bey M.J., Brock S.K., Beierwaltes W.N., Zauel R., Kolowich P.A., Lock T.R. In vivo measurement of subacromial space width during shoulder elevation: technique and preliminary results in patients following unilateral rotator cuff repair. Clin. Biomech. (Bristol, Avon.) 2007, 22(7):767-773.
    • (2007) Clin. Biomech. (Bristol, Avon.) , vol.22 , Issue.7 , pp. 767-773
    • Bey, M.J.1    Brock, S.K.2    Beierwaltes, W.N.3    Zauel, R.4    Kolowich, P.A.5    Lock, T.R.6
  • 4
    • 80052661778 scopus 로고    scopus 로고
    • In vivo measurement of glenohumeral joint contact patterns. EURASIP Journal on Advances in Signal Processing, 6, 201010.1155/2010/162136
    • Bey, M., Kline, S., Zauel, R., Kolowich, P., Lock, T.. In vivo measurement of glenohumeral joint contact patterns. EURASIP Journal on Advances in Signal Processing, 6, 201010.1155/2010/162136.
    • Bey, M.1    Kline, S.2    Zauel, R.3    Kolowich, P.4    Lock, T.5
  • 5
    • 0031761815 scopus 로고    scopus 로고
    • Biomechanics of windmill softball pitching with implications about injury mechanisms at the shoulder and elbow
    • Barrentine S.W., Fleisig G.S., Whiteside J.A., Escamilla R.F., Andrews J.R. Biomechanics of windmill softball pitching with implications about injury mechanisms at the shoulder and elbow. J. Orthop. Sports Phys. Ther. 1998, 28(6):405-415.
    • (1998) J. Orthop. Sports Phys. Ther. , vol.28 , Issue.6 , pp. 405-415
    • Barrentine, S.W.1    Fleisig, G.S.2    Whiteside, J.A.3    Escamilla, R.F.4    Andrews, J.R.5
  • 7
    • 33746919950 scopus 로고    scopus 로고
    • Validation of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics
    • Bey M.J., Zauel R., Brock S.K., Tashman S. Validation of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics. J. Biomech. Eng. 2006, 128(4):604-609.
    • (2006) J. Biomech. Eng. , vol.128 , Issue.4 , pp. 604-609
    • Bey, M.J.1    Zauel, R.2    Brock, S.K.3    Tashman, S.4
  • 8
    • 37249006719 scopus 로고    scopus 로고
    • Image-based RSA: Roentgen stereophotogrammetric analysis based on 2D-3D image registration
    • de Bruin P.W., Kaptein B.L., Stoel B.C., Reiber J.H., Rozing P.M., Valstar E.R. Image-based RSA: Roentgen stereophotogrammetric analysis based on 2D-3D image registration. J. Biomech. 2008, 41(1):155-164.
    • (2008) J. Biomech. , vol.41 , Issue.1 , pp. 155-164
    • de Bruin, P.W.1    Kaptein, B.L.2    Stoel, B.C.3    Reiber, J.H.4    Rozing, P.M.5    Valstar, E.R.6
  • 11
    • 38349153122 scopus 로고    scopus 로고
    • Biomechanical comparison of the fastball from wind-up and the fastball from stretch in professional baseball pitchers
    • Dun S., Kingsley D., Fleisig G.S., Loftice J., Andrews J.R. Biomechanical comparison of the fastball from wind-up and the fastball from stretch in professional baseball pitchers. Am. J. Sports Med. 2008, 36(1):137-141.
    • (2008) Am. J. Sports Med. , vol.36 , Issue.1 , pp. 137-141
    • Dun, S.1    Kingsley, D.2    Fleisig, G.S.3    Loftice, J.4    Andrews, J.R.5
  • 12
    • 21444457742 scopus 로고    scopus 로고
    • Three-dimensional scapulothoracic motion during active and passive arm elevation
    • Ebaugh D.D., McClure P.W., Karduna A.R. Three-dimensional scapulothoracic motion during active and passive arm elevation. Clin. Biomech. (Bristol, Avon) 2005, 20(7):700-709.
    • (2005) Clin. Biomech. (Bristol, Avon) , vol.20 , Issue.7 , pp. 700-709
    • Ebaugh, D.D.1    McClure, P.W.2    Karduna, A.R.3
  • 13
    • 0036321805 scopus 로고    scopus 로고
    • Relevance of arm position and muscle activity on three-dimensional glenohumeral translation in patients with traumatic and atraumatic shoulder instability
    • von Eisenhart-Rothe R.M., Jager A., Englmeier K.H., Vogl T.J., Graichen H. Relevance of arm position and muscle activity on three-dimensional glenohumeral translation in patients with traumatic and atraumatic shoulder instability. Am. J. Sports Med. 2002, 30(4):514-522.
    • (2002) Am. J. Sports Med. , vol.30 , Issue.4 , pp. 514-522
    • von Eisenhart-Rothe, R.M.1    Jager, A.2    Englmeier, K.H.3    Vogl, T.J.4    Graichen, H.5
  • 14
    • 38149025501 scopus 로고    scopus 로고
    • Three-dimensional scapular kinematics and scapulohumeral rhythm in patients with glenohumeral osteoarthritis or frozen shoulder
    • Fayad F., Roby-Brami A., Yazbeck C., Hanneton S., Lefevre-Colau M.M., Gautheron V., Poiraudeau S., Revel M. Three-dimensional scapular kinematics and scapulohumeral rhythm in patients with glenohumeral osteoarthritis or frozen shoulder. J. Biomech. 2008, 41(2):326-332.
    • (2008) J. Biomech. , vol.41 , Issue.2 , pp. 326-332
    • Fayad, F.1    Roby-Brami, A.2    Yazbeck, C.3    Hanneton, S.4    Lefevre-Colau, M.M.5    Gautheron, V.6    Poiraudeau, S.7    Revel, M.8
  • 17
    • 0033994514 scopus 로고    scopus 로고
    • Glenohumeral translation during active and passive elevation of the shoulder-a 3D open-MRI study
    • Graichen H., Stammberger T., Bonel H., Karl-Hans E., Reiser M., Eckstein F. Glenohumeral translation during active and passive elevation of the shoulder-a 3D open-MRI study. J. Biomech. 2000, 33(5):609-613.
    • (2000) J. Biomech. , vol.33 , Issue.5 , pp. 609-613
    • Graichen, H.1    Stammberger, T.2    Bonel, H.3    Karl-Hans, E.4    Reiser, M.5    Eckstein, F.6
  • 18
    • 0031455395 scopus 로고    scopus 로고
    • The accuracy and reproducibility of a global method to correct for geometric image distortion in the X-ray imaging chain
    • Gronenschild E. The accuracy and reproducibility of a global method to correct for geometric image distortion in the X-ray imaging chain. Med. Phys. 1997, 24(12):1875-1888.
    • (1997) Med. Phys. , vol.24 , Issue.12 , pp. 1875-1888
    • Gronenschild, E.1
  • 19
    • 0033430134 scopus 로고    scopus 로고
    • Correction for geometric image distortion in the X-ray imaging chain: local technique versus global technique
    • Gronenschild E. Correction for geometric image distortion in the X-ray imaging chain: local technique versus global technique. Med. Phys. 1999, 26(12):2602-2616.
    • (1999) Med. Phys. , vol.26 , Issue.12 , pp. 2602-2616
    • Gronenschild, E.1
  • 23
    • 33746892672 scopus 로고    scopus 로고
    • Shoulder kinematics in 25 patients with impingement and 12 controls
    • Hallstrom E., Karrholm J. Shoulder kinematics in 25 patients with impingement and 12 controls. Clin. Orthop. Relat. Res. 2006, 448:22-27.
    • (2006) Clin. Orthop. Relat. Res. , vol.448 , pp. 22-27
    • Hallstrom, E.1    Karrholm, J.2
  • 24
    • 74249106724 scopus 로고    scopus 로고
    • Shoulder rhythm in patients with impingement and in controls
    • Hallstrom E., Karrholm J. Shoulder rhythm in patients with impingement and in controls. Acta. Orthop. 2009, 80(4):456-464.
    • (2009) Acta. Orthop. , vol.80 , Issue.4 , pp. 456-464
    • Hallstrom, E.1    Karrholm, J.2
  • 25
    • 74249090440 scopus 로고    scopus 로고
    • External rotation during elevation of the arm
    • Inui H., Hashimoto T., Nobuhara K. External rotation during elevation of the arm. Acta. Orthop. 2009, 451-455.
    • (2009) Acta. Orthop. , pp. 451-455
    • Inui, H.1    Hashimoto, T.2    Nobuhara, K.3
  • 27
    • 67349144100 scopus 로고    scopus 로고
    • Comparative accuracy of radiostereometric and optical tracking systems
    • Kedgley A.E., Birmingham T., Jenkyn T.R. Comparative accuracy of radiostereometric and optical tracking systems. J. Biomech. 2009, 42(9):1350-1354.
    • (2009) J. Biomech. , vol.42 , Issue.9 , pp. 1350-1354
    • Kedgley, A.E.1    Birmingham, T.2    Jenkyn, T.R.3
  • 28
    • 0035038054 scopus 로고    scopus 로고
    • Dynamic measurements of three-dimensional scapular kinematics: a validation study
    • Karduna A.R., McClure P.W., Michener L.A., Sennett B. Dynamic measurements of three-dimensional scapular kinematics: a validation study. J. Biomech. Eng. 2001, 123(2):184-190.
    • (2001) J. Biomech. Eng. , vol.123 , Issue.2 , pp. 184-190
    • Karduna, A.R.1    McClure, P.W.2    Michener, L.A.3    Sennett, B.4
  • 29
    • 2442584529 scopus 로고    scopus 로고
    • Feasibility of using orthogonal fluoroscopic images to measure in vivo joint kinematics
    • Li G., Wuerz T.H., DeFrate L.E. Feasibility of using orthogonal fluoroscopic images to measure in vivo joint kinematics. J. Biomech. Eng. 2004, 126(2):314-318.
    • (2004) J. Biomech. Eng. , vol.126 , Issue.2 , pp. 314-318
    • Li, G.1    Wuerz, T.H.2    DeFrate, L.E.3
  • 30
    • 42749092342 scopus 로고    scopus 로고
    • Validation of a non-invasive fluoroscopic imaging technique for the measurement of dynamic knee joint motion
    • Li G., Van de Velde S.K., Bingham J.T. Validation of a non-invasive fluoroscopic imaging technique for the measurement of dynamic knee joint motion. J. Biomech. 2008, 41(7):1616-1622.
    • (2008) J. Biomech. , vol.41 , Issue.7 , pp. 1616-1622
    • Li, G.1    Van de Velde, S.K.2    Bingham, J.T.3
  • 31
    • 0035351457 scopus 로고    scopus 로고
    • Direct 3-dimensional measurement of scapular kinematics during dynamic movements in vivo
    • McClure P.W., Michener L.A., Sennett B.J., Karduna A.R. Direct 3-dimensional measurement of scapular kinematics during dynamic movements in vivo. J. Shoulder Elbow Surg. 2001, 10(3):269-277.
    • (2001) J. Shoulder Elbow Surg. , vol.10 , Issue.3 , pp. 269-277
    • McClure, P.W.1    Michener, L.A.2    Sennett, B.J.3    Karduna, A.R.4
  • 33
    • 77951892515 scopus 로고    scopus 로고
    • Glenohumeral contact kinematics in patients after total shoulder arthroplasty
    • Massimini D.F., Li G., Warner J.P. Glenohumeral contact kinematics in patients after total shoulder arthroplasty. J. Bone Jt. Surg. Am. 2010, 92(4):916-926.
    • (2010) J. Bone Jt. Surg. Am. , vol.92 , Issue.4 , pp. 916-926
    • Massimini, D.F.1    Li, G.2    Warner, J.P.3
  • 34
    • 40149108188 scopus 로고    scopus 로고
    • Determination of in vivo glenohumeral translation using fluoroscopy and shape-matching techniques
    • Nishinaka N., et al. Determination of in vivo glenohumeral translation using fluoroscopy and shape-matching techniques. J. Shoulder Elbow Surg. 2008, 17(2):319-322.
    • (2008) J. Shoulder Elbow Surg. , vol.17 , Issue.2 , pp. 319-322
    • Nishinaka, N.1
  • 36
    • 0024388994 scopus 로고
    • Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system
    • Selvik G. Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system. Acta. Orthop. Scand. Suppl. 1989, 232:1-51.
    • (1989) Acta. Orthop. Scand. Suppl. , vol.232 , pp. 1-51
    • Selvik, G.1
  • 37
    • 0037396234 scopus 로고    scopus 로고
    • In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: application to canine ACL deficiency
    • Tashman S., Anderst W. In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: application to canine ACL deficiency. J. Biomech. Eng. 2003, 125(2):238-245.
    • (2003) J. Biomech. Eng. , vol.125 , Issue.2 , pp. 238-245
    • Tashman, S.1    Anderst, W.2
  • 38
    • 0032071198 scopus 로고    scopus 로고
    • Fast and accurate automated measurements in digitized stereophotogrammetric radiographs
    • Vrooman H.A., Valstar E.R., Brand G.J., Admiraal D.R., Rozing P.M., Reiber J.H. Fast and accurate automated measurements in digitized stereophotogrammetric radiographs. J. Biomech. 1998, 31(5):491-498.
    • (1998) J. Biomech. , vol.31 , Issue.5 , pp. 491-498
    • Vrooman, H.A.1    Valstar, E.R.2    Brand, G.J.3    Admiraal, D.R.4    Rozing, P.M.5    Reiber, J.H.6
  • 40
    • 52649155534 scopus 로고    scopus 로고
    • In vivo contact kinematics and contact forces of the knee after total knee arthroplasty during dynamic weight-bearing activities
    • Varadarajan K.M., Moynihan A.L., D'Lima D., Colwell C.W., Li G. In vivo contact kinematics and contact forces of the knee after total knee arthroplasty during dynamic weight-bearing activities. J. Biomech. 2008, 41(10):2159-2168.
    • (2008) J. Biomech. , vol.41 , Issue.10 , pp. 2159-2168
    • Varadarajan, K.M.1    Moynihan, A.L.2    D'Lima, D.3    Colwell, C.W.4    Li, G.5
  • 41
    • 43549086673 scopus 로고    scopus 로고
    • Measurement of vertebral kinematics using noninvasive image matching method-validation and application
    • Wang S., Passias P., Li G., Wood K. Measurement of vertebral kinematics using noninvasive image matching method-validation and application. Spine (Phila Pa 1976) 2008, 33(11):E355-E361.
    • (2008) Spine (Phila Pa 1976) , vol.33 , Issue.11
    • Wang, S.1    Passias, P.2    Li, G.3    Wood, K.4
  • 42
    • 33751199926 scopus 로고    scopus 로고
    • Determination of in-vivo articular cartilage contact areas of human talocrural joint under weightbearing conditions
    • Wan L., de Asla R.J., Rubash H.E., Li G. Determination of in-vivo articular cartilage contact areas of human talocrural joint under weightbearing conditions. Osteoarthritis Cartilage 2006, 14(12):1294-1301.
    • (2006) Osteoarthritis Cartilage , vol.14 , Issue.12 , pp. 1294-1301
    • Wan, L.1    de Asla, R.J.2    Rubash, H.E.3    Li, G.4
  • 43
    • 20144387878 scopus 로고    scopus 로고
    • ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion-Part II: shoulder, elbow, wrist and hand
    • Wu G., et al. ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion-Part II: shoulder, elbow, wrist and hand. J. Biomech. 2005, 38(5):981-992.
    • (2005) J. Biomech. , vol.38 , Issue.5 , pp. 981-992
    • Wu, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.