메뉴 건너뛰기




Volumn 35, Issue 1, 2011, Pages 74-80

Mechanical Properties of Open-Cell, Self-Expandable Shape Memory Alloy Carotid Stents

Author keywords

Bending stiffness; Carotid stents; Radial stiffness; Shape memory alloy

Indexed keywords

BENDING TESTS; BIOMECHANICS; CELLS; CYTOLOGY; SHAPE MEMORY EFFECT; STIFFNESS; STRUTS;

EID: 78651429006     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2010.01018.x     Document Type: Article
Times cited : (29)

References (14)
  • 1
    • 45749128980 scopus 로고    scopus 로고
    • How I interpreted the randomised trials of carotid angioplasty/stenting versus endarterectomy
    • Hankey GJ. How I interpreted the randomised trials of carotid angioplasty/stenting versus endarterectomy. Eur J Vasc Endovasc Surg 2008;36:34-40.
    • (2008) Eur J Vasc Endovasc Surg , vol.36 , pp. 34-40
    • Hankey, G.J.1
  • 2
    • 0033011716 scopus 로고    scopus 로고
    • Radial force of coronary stents: a comparative analysis
    • Rieu R, Barragan P, Masson C, et al. Radial force of coronary stents: a comparative analysis. Catheter Cardiovasc Interv 1999;46:380-91.
    • (1999) Catheter Cardiovasc Interv , vol.46 , pp. 380-391
    • Rieu, R.1    Barragan, P.2    Masson, C.3
  • 4
    • 0042830784 scopus 로고    scopus 로고
    • Mechanical properties of various z-stent designs: an endovascular stent-grafting perspective
    • Bashar AH, Kazui T, Washiyama N, Terada H, Yamashita K, Haque ME. Mechanical properties of various z-stent designs: an endovascular stent-grafting perspective. Artif Organs 2003;7:714-21.
    • (2003) Artif Organs , vol.7 , pp. 714-721
    • Bashar, A.H.1    Kazui, T.2    Washiyama, N.3    Terada, H.4    Yamashita, K.5    Haque, M.E.6
  • 5
    • 1442299848 scopus 로고    scopus 로고
    • Numerical investigation of the intravascular coronary stent flexibility
    • Petrini L, Migliavacca F, Auricchio F, Dubini G. Numerical investigation of the intravascular coronary stent flexibility. J Biomech 2004;37:495-501.
    • (2004) J Biomech , vol.37 , pp. 495-501
    • Petrini, L.1    Migliavacca, F.2    Auricchio, F.3    Dubini, G.4
  • 6
    • 21144448039 scopus 로고    scopus 로고
    • Effects of stent structure on stent flexibility measurements
    • Mori K, Saito T. Effects of stent structure on stent flexibility measurements. Ann Biomed Eng 2005;33:733-42.
    • (2005) Ann Biomed Eng , vol.33 , pp. 733-742
    • Mori, K.1    Saito, T.2
  • 8
    • 67649277704 scopus 로고    scopus 로고
    • Measurement of radial and axial forces of biliary self-expandable metallic stents
    • Isayama H, Nakai Y, Toyokawa Y, et al. Measurement of radial and axial forces of biliary self-expandable metallic stents. Gastrointest Endosc 2009;70:37-44.
    • (2009) Gastrointest Endosc , vol.70 , pp. 37-44
    • Isayama, H.1    Nakai, Y.2    Toyokawa, Y.3
  • 10
    • 33846244289 scopus 로고    scopus 로고
    • Does free cell area influence the outcome in carotid artery stenting?
    • Bosiers M, de Donato G, Deloose K, et al. Does free cell area influence the outcome in carotid artery stenting? Eur J Vasc Endovasc Surg 2007;33:135-41.
    • (2007) Eur J Vasc Endovasc Surg , vol.33 , pp. 135-141
    • Bosiers, M.1    de Donato, G.2    Deloose, K.3
  • 11
    • 43549092615 scopus 로고    scopus 로고
    • What practical factors guide the choice of stent and protection device during carotid angioplasty?
    • Bosiers M, Deloose K, Verbist J, Peeters P. What practical factors guide the choice of stent and protection device during carotid angioplasty? Eur J Vasc Endovasc Surg 2008;35:637-43.
    • (2008) Eur J Vasc Endovasc Surg , vol.35 , pp. 637-643
    • Bosiers, M.1    Deloose, K.2    Verbist, J.3    Peeters, P.4
  • 12
  • 13
    • 49849099228 scopus 로고    scopus 로고
    • Carotid stent cell design: lack of benefit or lack of evidence?
    • Author reply e133.
    • Cremonesi A, Setacci C, Castriota F, Valgimigli M. Carotid stent cell design: lack of benefit or lack of evidence? Stroke 2009;39:e130. Author reply e133.
    • (2009) Stroke , vol.39
    • Cremonesi, A.1    Setacci, C.2    Castriota, F.3    Valgimigli, M.4
  • 14
    • 49849087131 scopus 로고    scopus 로고
    • Two different studies on carotid stent cell design importance, or are we just saying the same thing?
    • Author reply e133. Epub 2008 Jun 26.
    • Setacci C, de Donato G, Bosiers M. Two different studies on carotid stent cell design importance, or are we just saying the same thing? Stroke 2008;39:e129. Author reply e133. Epub 2008 Jun 26.
    • (2008) Stroke , vol.39
    • Setacci, C.1    de Donato, G.2    Bosiers, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.