메뉴 건너뛰기




Volumn 56, Issue 1, 2011, Pages 25-35

How often does patient-ventilator asynchrony occur and what are the consequences?

Author keywords

Mechanical ventilation; Patient ventilator asynchrony; Trigger asynchrony; Weaning

Indexed keywords

ADVERSE OUTCOME; ARTICLE; ARTIFICIAL VENTILATION; BREATHING APPARATUS; CONFUSION; DIAPHRAGM PARALYSIS; HUMAN; LENGTH OF STAY; LUNG INJURY; LUNG VENTILATION; OUTCOME ASSESSMENT; PATIENT ASSESSMENT; PATIENT VENTILATOR ASYNCHRONY; PRESSURE SUPPORT VENTILATION; PROGNOSIS; RESPIRATION CONTROL; RESPIRATORY AIRFLOW; RESPIRATORY CARE;

EID: 78651399802     PISSN: 00201324     EISSN: 19433654     Source Type: Journal    
DOI: 10.4187/respcare.01009     Document Type: Article
Times cited : (107)

References (69)
  • 1
    • 0028128027 scopus 로고
    • Diaphragm injury and myofibrillar structure induced by resistive loading
    • Reid WD, Huang J, Bryson S, Walker DC, Belcastro AN. Diaphragm injury and myofibrillar structure induced by resistive loading. J Appl Physiol 1994;76(1):176-184.
    • (1994) J Appl Physiol , vol.76 , Issue.1 , pp. 176-184
    • Reid, W.D.1    Huang, J.2    Bryson, S.3    Walker, D.C.4    Belcastro, A.N.5
  • 3
    • 0036082131 scopus 로고    scopus 로고
    • Altered diaphragm contractile properties with controlled mechanical ventilation
    • Sassoon CS, Caiozzo VJ, Manka A, Sieck GC. Altered diaphragm contractile properties with controlled mechanical ventilation. J Appl Physiol 2002;92(6):2585-2595.
    • (2002) J Appl Physiol , vol.92 , Issue.6 , pp. 2585-2595
    • Sassoon, C.S.1    Caiozzo, V.J.2    Manka, A.3    Sieck, G.C.4
  • 6
    • 0034899317 scopus 로고    scopus 로고
    • Optimizing patient-ventilator synchrony
    • Epstein SK. Optimizing patient-ventilator synchrony. Semin Respir Crit Care Med 2001;22(2):137-152.
    • (2001) Semin Respir Crit Care Med , vol.22 , Issue.2 , pp. 137-152
    • Epstein, S.K.1
  • 7
    • 34447627194 scopus 로고    scopus 로고
    • Clinical review: Patient-ventilator interaction in chronic obstructive pulmonary disease
    • Jolliet P, Tassaux D. Clinical review: patient-ventilator interaction in chronic obstructive pulmonary disease. Crit Care 2006;10(6):236.
    • (2006) Crit Care , vol.10 , Issue.6 , pp. 236
    • Jolliet, P.1    Tassaux, D.2
  • 8
    • 0029820390 scopus 로고    scopus 로고
    • Patient-ventilator interactions
    • Dick CR, Sassoon CS. Patient-ventilator interactions. Clin Chest Med 1996;17(3):423-438.
    • (1996) Clin Chest Med , vol.17 , Issue.3 , pp. 423-438
    • Dick, C.R.1    Sassoon, C.S.2
  • 10
    • 20344386217 scopus 로고    scopus 로고
    • Patient-ventilator interaction during the triggering phase
    • Racca F, Squadrone V, Ranieri VM. Patient-ventilator interaction during the triggering phase. Respir Care Clin N Am 2005;11(2):225-245.
    • (2005) Respir Care Clin N Am , vol.11 , Issue.2 , pp. 225-245
    • Racca, F.1    Squadrone, V.2    Ranieri, V.M.3
  • 12
    • 0034049485 scopus 로고    scopus 로고
    • Flow triggering, pressure triggering, and autotriggering during mechanical ventilation
    • Hill LL, Pearl RG. Flow triggering, pressure triggering, and autotriggering during mechanical ventilation. Crit Care Med 2000;28(2): 579-581.
    • (2000) Crit Care Med , vol.28 , Issue.2 , pp. 579-581
    • Hill, L.L.1    Pearl, R.G.2
  • 13
    • 3142708525 scopus 로고    scopus 로고
    • Exhaled tidal volume overestimation in mechanically ventilated patients with large cardiogenic oscillation
    • Imanaka H, Takeuchi M, Tachibana K, Nishimura M. Exhaled tidal volume overestimation in mechanically ventilated patients with large cardiogenic oscillation. Crit Care Med 2004;32(7):1546-1549.
    • (2004) Crit Care Med , vol.32 , Issue.7 , pp. 1546-1549
    • Imanaka, H.1    Takeuchi, M.2    Tachibana, K.3    Nishimura, M.4
  • 14
    • 33846020584 scopus 로고    scopus 로고
    • Modulation and treatment of patient-ventilator dyssynchrony
    • Kondili E, Xirouchaki N, Georgopoulos D. Modulation and treatment of patient-ventilator dyssynchrony. Curr Opin Crit Care 2007; 13(1):84-89.
    • (2007) Curr Opin Crit Care , vol.13 , Issue.1 , pp. 84-89
    • Kondili, E.1    Xirouchaki, N.2    Georgopoulos, D.3
  • 15
    • 67650787019 scopus 로고    scopus 로고
    • A bench study of intensive-care-unit ventilators: New versus old and turbinebased versus compressed gas-based ventilators
    • Thille AW, Lyazidi A, Richard JC, Galia F, Brochard L. A bench study of intensive-care-unit ventilators: new versus old and turbinebased versus compressed gas-based ventilators. Intensive Care Med 2009;35(8):1368-1376.
    • (2009) Intensive Care Med , vol.35 , Issue.8 , pp. 1368-1376
    • Thille, A.W.1    Lyazidi, A.2    Richard, J.C.3    Galia, F.4    Brochard, L.5
  • 16
    • 0036360893 scopus 로고    scopus 로고
    • Bench testing of pressure support ventilation with three different generations of ventilators
    • Richard JC, Carlucci A, Breton L, Langlais N, Jaber S, Maggiore S, et al. Bench testing of pressure support ventilation with three different generations of ventilators. Intensive Care Med 2002;28(8):1049-1057.
    • (2002) Intensive Care Med , vol.28 , Issue.8 , pp. 1049-1057
    • Richard, J.C.1    Carlucci, A.2    Breton, L.3    Langlais, N.4    Jaber, S.5    Maggiore, S.6
  • 17
    • 0030760991 scopus 로고    scopus 로고
    • Patient-ventilator flow dyssynchrony: Flow-limited versus pressure-limited breaths
    • MacIntyre NR, McConnell R, Cheng KC, Sane A. Patient-ventilator flow dyssynchrony: flow-limited versus pressure-limited breaths. Crit Care Med 1997;25(10):1671-1677.
    • (1997) Crit Care Med , vol.25 , Issue.10 , pp. 1671-1677
    • MacIntyre, N.R.1    McConnell, R.2    Cheng, K.C.3    Sane, A.4
  • 18
    • 0021953910 scopus 로고
    • The inspiratory work of breathing during assisted mechanical ventilation
    • Marini JJ, Capps JS, Culver BH. The inspiratory work of breathing during assisted mechanical ventilation. Chest 1985;87(5):612-618.
    • (1985) Chest , vol.87 , Issue.5 , pp. 612-618
    • Marini, J.J.1    Capps, J.S.2    Culver, B.H.3
  • 19
    • 0023685509 scopus 로고
    • External work output and force generation during synchronized intermittent mechanical ventilation: Effect of machine assistance on breathing effort
    • Marini JJ, Smith TC, Lamb VJ. External work output and force generation during synchronized intermittent mechanical ventilation: effect of machine assistance on breathing effort. Am Rev Respir Dis 1988;138(5):1169-1179.
    • (1988) Am Rev Respir Dis , vol.138 , Issue.5 , pp. 1169-1179
    • Marini, J.J.1    Smith, T.C.2    Lamb, V.J.3
  • 20
    • 0022631006 scopus 로고
    • Bedside estimation of the inspiratory work of breathing during mechanical ventilation
    • Marini JJ, Rodriguez RM, Lamb V. Bedside estimation of the inspiratory work of breathing during mechanical ventilation. Chest 1986;89(1):56-63.
    • (1986) Chest , vol.89 , Issue.1 , pp. 56-63
    • Marini, J.J.1    Rodriguez, R.M.2    Lamb, V.3
  • 22
    • 0033837011 scopus 로고    scopus 로고
    • Assessment of neural inspiratory time in ventilator-supported patients
    • Parthasarathy S, Jubran A, Tobin MJ. Assessment of neural inspiratory time in ventilator-supported patients. Am J Respir Crit Care Med 2000;162(2 Pt 1):546-552.
    • (2000) Am J Respir Crit Care Med , vol.162 , Issue.2 PART 1 , pp. 546-552
    • Parthasarathy, S.1    Jubran, A.2    Tobin, M.J.3
  • 23
    • 0031788771 scopus 로고    scopus 로고
    • Cycling of inspiratory and expiratory muscle groups with the ventilator in airflow limitation
    • Parthasarathy S, Jubran A, Tobin MJ. Cycling of inspiratory and expiratory muscle groups with the ventilator in airflow limitation. Am J Respir Crit Care Med 1998;158(5 Pt 1):1471-1478.
    • (1998) Am J Respir Crit Care Med , vol.158 , Issue.5 PART 1 , pp. 1471-1478
    • Parthasarathy, S.1    Jubran, A.2    Tobin, M.J.3
  • 25
    • 38549162063 scopus 로고    scopus 로고
    • Detecting ineffective triggering in the expiratory phase in mechanically ventilated patients based on airway flow and pressure deflection: Feasibility of using a computer algorithm
    • Chen CW, Lin WC, Hsu CH, Cheng KS, Lo CS. Detecting ineffective triggering in the expiratory phase in mechanically ventilated patients based on airway flow and pressure deflection: feasibility of using a computer algorithm. Crit Care Med 2008;36(2):455-461.
    • (2008) Crit Care Med , vol.36 , Issue.2 , pp. 455-461
    • Chen, C.W.1    Lin, W.C.2    Hsu, C.H.3    Cheng, K.S.4    Lo, C.S.5
  • 26
    • 0032993065 scopus 로고    scopus 로고
    • Response of ventilatordependent patients to different levels of pressure support and proportional assist
    • Giannouli E, Webster K, Roberts D, Younes M. Response of ventilatordependent patients to different levels of pressure support and proportional assist. Am J Respir Crit Care Med 1999;159(6):1716-1725.
    • (1999) Am J Respir Crit Care Med , vol.159 , Issue.6 , pp. 1716-1725
    • Giannouli, E.1    Webster, K.2    Roberts, D.3    Younes, M.4
  • 27
    • 49749094369 scopus 로고    scopus 로고
    • Subject-ventilator synchrony during neural versus pneumatically triggered non-invasive helmet ventilation
    • Moerer O, Beck J, Brander L, Costa R, Quintel M, Slutsky AS, et al. Subject-ventilator synchrony during neural versus pneumatically triggered non-invasive helmet ventilation. Intensive Care Med 2008; 34(9):1615-1623.
    • (2008) Intensive Care Med , vol.34 , Issue.9 , pp. 1615-1623
    • Moerer, O.1    Beck, J.2    Brander, L.3    Costa, R.4    Quintel, M.5    Slutsky, A.S.6
  • 28
    • 30444440045 scopus 로고    scopus 로고
    • Impact of expiratory trigger setting on delayed cycling and inspiratory muscle workload
    • Tassaux D, Gainnier M, Battisti A, Jolliet P. Impact of expiratory trigger setting on delayed cycling and inspiratory muscle workload. Am J Respir Crit Care Med 2005;172(10):1283-1289.
    • (2005) Am J Respir Crit Care Med , vol.172 , Issue.10 , pp. 1283-1289
    • Tassaux, D.1    Gainnier, M.2    Battisti, A.3    Jolliet, P.4
  • 29
    • 39049126473 scopus 로고    scopus 로고
    • Effect of different cycling-off criteria and positive end-expiratory pressure during pressure support ventilation in patients with chronic obstructive pulmonary disease
    • Chiumello D, Polli F, Tallarini F, Chierichetti M, Motta G, Azzari S, et al. Effect of different cycling-off criteria and positive end-expiratory pressure during pressure support ventilation in patients with chronic obstructive pulmonary disease. Crit Care Med 2007;35(11): 2547-2552.
    • (2007) Crit Care Med , vol.35 , Issue.11 , pp. 2547-2552
    • Chiumello, D.1    Polli, F.2    Tallarini, F.3    Chierichetti, M.4    Motta, G.5    Azzari, S.6
  • 30
    • 0344442327 scopus 로고    scopus 로고
    • Effect of different inspiratory rise time and cycling off criteria during pressure support ventilation in patients recovering from acute lung injury
    • Chiumello D, Pelosi P, Taccone P, Slutsky A, Gattinoni L. Effect of different inspiratory rise time and cycling off criteria during pressure support ventilation in patients recovering from acute lung injury. Crit Care Med 2003;31(11):2604-2610.
    • (2003) Crit Care Med , vol.31 , Issue.11 , pp. 2604-2610
    • Chiumello, D.1    Pelosi, P.2    Taccone, P.3    Slutsky, A.4    Gattinoni, L.5
  • 31
    • 0035161013 scopus 로고    scopus 로고
    • The effect of breath termination criterion on breathing patterns and the work of breathing during pressure support ventilation
    • Tokioka H, Tanaka T, Ishizu T, Fukushima T, Iwaki T, Nakamura Y, et al. The effect of breath termination criterion on breathing patterns and the work of breathing during pressure support ventilation. Anesth Analg 2001;92(1):161-165.
    • (2001) Anesth Analg , vol.92 , Issue.1 , pp. 161-165
    • Tokioka, H.1    Tanaka, T.2    Ishizu, T.3    Fukushima, T.4    Iwaki, T.5    Nakamura, Y.6
  • 32
    • 0036483168 scopus 로고    scopus 로고
    • Detection of patient-ventilator asynchrony during low tidal volume ventilation, using ventilator waveform graphics
    • Kallet RH, Luce JM. Detection of patient-ventilator asynchrony during low tidal volume ventilation, using ventilator waveform graphics. Respir Care 2002;47(2):183-185.
    • (2002) Respir Care , vol.47 , Issue.2 , pp. 183-185
    • Kallet, R.H.1    Luce, J.M.2
  • 34
    • 0024509825 scopus 로고
    • Importance of trigger sensitivity to ventilator response delay in advanced chronic obstructive pulmonary disease with respiratory failure
    • Gurevitch MJ, Gelmont D. Importance of trigger sensitivity to ventilator response delay in advanced chronic obstructive pulmonary disease with respiratory failure. Crit Care Med 1989;17(4):354-359.
    • (1989) Crit Care Med , vol.17 , Issue.4 , pp. 354-359
    • Gurevitch, M.J.1    Gelmont, D.2
  • 35
    • 0016799618 scopus 로고
    • Asynchronous breathing movements in patients with chronic obstructive pulmonary disease
    • Ashutosh K, Gilbert R, Auchincloss JH, Jr., Peppi D. Asynchronous breathing movements in patients with chronic obstructive pulmonary disease. Chest 1975;67(5):553-557.
    • (1975) Chest , vol.67 , Issue.5 , pp. 553-557
    • Ashutosh, K.1    Gilbert, R.2    Auchincloss Jr., J.H.3    Peppi, D.4
  • 36
    • 0029014749 scopus 로고
    • An analysis of desynchronization between the spontaneously breathing patient and ventilator during inspiratory pressure support
    • Fabry B, Guttmann J, Eberhard L, Bauer T, Haberthur C, Wolff G. An analysis of desynchronization between the spontaneously breathing patient and ventilator during inspiratory pressure support. Chest 1995;107(5):1387-1394.
    • (1995) Chest , vol.107 , Issue.5 , pp. 1387-1394
    • Fabry, B.1    Guttmann, J.2    Eberhard, L.3    Bauer, T.4    Haberthur, C.5    Wolff, G.6
  • 37
    • 0031033608 scopus 로고    scopus 로고
    • Patientventilator interaction and inspiratory effort during pressure support ventilation in patients with different pathologies
    • Nava, S, Bruschi, C, Fracchia, C, Braschi, A, Rubini, F. Patientventilator interaction and inspiratory effort during pressure support ventilation in patients with different pathologies. Eur Respir J 1997; 10(1):177-183.
    • (1997) Eur Respir J , vol.10 , Issue.1 , pp. 177-183
    • Nava, S.1    Bruschi, C.2    Fracchia, C.3    Braschi, A.4    Rubini, F.5
  • 38
    • 48149098373 scopus 로고    scopus 로고
    • Reduction of patient-ventilator asynchrony by reducing tidal volume during pressure- support ventilation
    • Thille AW, Cabello B, Galia F, Lyazidi A, Brochard L. Reduction of patient-ventilator asynchrony by reducing tidal volume during pressure- support ventilation. Intensive Care Med 2008;34(8):1477-1486.
    • (2008) Intensive Care Med , vol.34 , Issue.8 , pp. 1477-1486
    • Thille, A.W.1    Cabello, B.2    Galia, F.3    Lyazidi, A.4    Brochard, L.5
  • 39
    • 0029121830 scopus 로고
    • Variability of patientventilator interaction with pressure support ventilation in patients with chronic obstructive pulmonary disease
    • Jubran A, Van de Graaff WB, Tobin MJ. Variability of patientventilator interaction with pressure support ventilation in patients with chronic obstructive pulmonary disease. Am J Respir Crit Care Med 1995;152(1):129-136.
    • (1995) Am J Respir Crit Care Med , vol.152 , Issue.1 , pp. 129-136
    • Jubran, A.1    van de Graaff, W.B.2    Tobin, M.J.3
  • 40
    • 0030919104 scopus 로고    scopus 로고
    • Comparison of assisted ventilator modes on triggering, patient effort, and dyspnea
    • Leung P, Jubran A, Tobin MJ. Comparison of assisted ventilator modes on triggering, patient effort, and dyspnea. Am J Respir Crit Care Med 1997;155(6):1940-1948.
    • (1997) Am J Respir Crit Care Med , vol.155 , Issue.6 , pp. 1940-1948
    • Leung, P.1    Jubran, A.2    Tobin, M.J.3
  • 42
    • 67349181016 scopus 로고    scopus 로고
    • Patient-ventilator asynchrony during non-invasive ventilation for acute respiratory failure: A multicenter study
    • Vignaux L, Vargas F, Roeseler J, Tassaux D, Thille AW, Kossowsky MP, et al. Patient-ventilator asynchrony during non-invasive ventilation for acute respiratory failure: a multicenter study. Intensive Care Med 2009;35(5):840-846.
    • (2009) Intensive Care Med , vol.35 , Issue.5 , pp. 840-846
    • Vignaux, L.1    Vargas, F.2    Roeseler, J.3    Tassaux, D.4    Thille, A.W.5    Kossowsky, M.P.6
  • 44
    • 54449099086 scopus 로고    scopus 로고
    • Physiologic response to varying levels of pressure support and neurally adjusted ventilatory assist in patients with acute respiratory failure
    • Colombo D, Cammarota G, Bergamaschi V, De Lucia M, Corte FD, Navalesi P. Physiologic response to varying levels of pressure support and neurally adjusted ventilatory assist in patients with acute respiratory failure. Intensive Care Med 2008;34(11): 2010-2018.
    • (2008) Intensive Care Med , vol.34 , Issue.11 , pp. 2010-2018
    • Colombo, D.1    Cammarota, G.2    Bergamaschi, V.3    de Lucia, M.4    Corte, F.D.5    Navalesi, P.6
  • 45
    • 74949087606 scopus 로고    scopus 로고
    • Patient-ventilator interaction during pressure support ventilation and neurally adjusted ventilatory assist
    • Spahija J, de Marchie M, Albert M, Bellemare P, Delisle S, Beck J, et al. Patient-ventilator interaction during pressure support ventilation and neurally adjusted ventilatory assist. Crit Care Med 2010; 38(2):518-526.
    • (2010) Crit Care Med , vol.38 , Issue.2 , pp. 518-526
    • Spahija, J.1    de Marchie, M.2    Albert, M.3    Bellemare, P.4    Delisle, S.5    Beck, J.6
  • 46
    • 54449085996 scopus 로고    scopus 로고
    • Proportional assist ventilation with load-adjustable gain factors in critically ill patients: Comparison with pressure support
    • Xirouchaki N, Kondili E, Vaporidi K, Xirouchakis G, Klimathianaki M, Gavriilidis G, et al. Proportional assist ventilation with load-adjustable gain factors in critically ill patients: comparison with pressure support. Intensive Care Med 2008;34(11):2026-2034.
    • (2008) Intensive Care Med , vol.34 , Issue.11 , pp. 2026-2034
    • Xirouchaki, N.1    Kondili, E.2    Vaporidi, K.3    Xirouchakis, G.4    Klimathianaki, M.5    Gavriilidis, G.6
  • 48
    • 0031468718 scopus 로고    scopus 로고
    • Patient-ventilator trigger asynchrony in prolonged mechanical ventilation
    • Chao DC, Scheinhorn DJ, Stearn-Hassenpflug M. Patient-ventilator trigger asynchrony in prolonged mechanical ventilation. Chest 1997; 112(6):1592-1599.
    • (1997) Chest , vol.112 , Issue.6 , pp. 1592-1599
    • Chao, D.C.1    Scheinhorn, D.J.2    Stearn-Hassenpflug, M.3
  • 49
    • 34250673261 scopus 로고    scopus 로고
    • Effect of sleep on patient/ventilator asynchrony in patients undergoing chronic non-invasive mechanical ventilation
    • Fanfulla F, Taurino AE, Lupo ND, Trentin R, D'Ambrosio C, Nava S. Effect of sleep on patient/ventilator asynchrony in patients undergoing chronic non-invasive mechanical ventilation. Respir Med 2007; 101(8):1702-1707.
    • (2007) Respir Med , vol.101 , Issue.8 , pp. 1702-1707
    • Fanfulla, F.1    Taurino, A.E.2    Lupo, N.D.3    Trentin, R.4    D'Ambrosio, C.5    Nava, S.6
  • 50
    • 34247174454 scopus 로고    scopus 로고
    • Patient-ventilator interaction and sleep in mechanically ventilated patients: Pressure support versus proportional assist ventilation
    • Bosma K, Ferreyra G, Ambrogio C, Pasero D, Mirabella L, Braghiroli A, et al. Patient-ventilator interaction and sleep in mechanically ventilated patients: pressure support versus proportional assist ventilation. Crit Care Med 2007;35(4):1048-1054.
    • (2007) Crit Care Med , vol.35 , Issue.4 , pp. 1048-1054
    • Bosma, K.1    Ferreyra, G.2    Ambrogio, C.3    Pasero, D.4    Mirabella, L.5    Braghiroli, A.6
  • 51
    • 4544292361 scopus 로고    scopus 로고
    • Assessment of physiologic variables and subjective comfort under different levels of pressure support ventilation
    • Vitacca M, Bianchi L, Zanotti E, Vianello A, Barbano L, Porta R, et al. Assessment of physiologic variables and subjective comfort under different levels of pressure support ventilation. Chest 2004;126(3): 851-859.
    • (2004) Chest , vol.126 , Issue.3 , pp. 851-859
    • Vitacca, M.1    Bianchi, L.2    Zanotti, E.3    Vianello, A.4    Barbano, L.5    Porta, R.6
  • 52
    • 61449194104 scopus 로고    scopus 로고
    • Observational study of patient-ventilator asynchrony and relationship to sedation level
    • de Wit M, Pedram S, Best AM, Epstein SK. Observational study of patient-ventilator asynchrony and relationship to sedation level. J Crit Care 2009;24(1):74-80.
    • (2009) J Crit Care , vol.24 , Issue.1 , pp. 74-80
    • de Wit, M.1    Pedram, S.2    Best, A.M.3    Epstein, S.K.4
  • 53
    • 0031028480 scopus 로고    scopus 로고
    • Pliometric contraction-induced injury of mouse skeletal muscle: Effect of initial length
    • Hunter KD, Faulkner JA. Pliometric contraction-induced injury of mouse skeletal muscle: effect of initial length. J Appl Physiol 1997; 82(1):278-283.
    • (1997) J Appl Physiol , vol.82 , Issue.1 , pp. 278-283
    • Hunter, K.D.1    Faulkner, J.A.2
  • 54
    • 0032858619 scopus 로고    scopus 로고
    • Regeneration of new fibers in muscles of old rats reduces contraction-induced injury
    • Devor ST, Faulkner JA. Regeneration of new fibers in muscles of old rats reduces contraction-induced injury. J Appl Physiol 1999;87(2): 750-756.
    • (1999) J Appl Physiol , vol.87 , Issue.2 , pp. 750-756
    • Devor, S.T.1    Faulkner, J.A.2
  • 55
    • 0033934190 scopus 로고    scopus 로고
    • Brainstem death and ventilator trigger settings
    • Willatts SM, Drummond G. Brainstem death and ventilator trigger settings. Anaesthesia 2000;55(7):676-677.
    • (2000) Anaesthesia , vol.55 , Issue.7 , pp. 676-677
    • Willatts, S.M.1    Drummond, G.2
  • 56
    • 0028889829 scopus 로고
    • Respiratory response and inspiratory effort during pressure support ventilation in COPD patients
    • Nava S, Bruschi C, Rubini F, Palo A, Iotti G, Braschi A. Respiratory response and inspiratory effort during pressure support ventilation in COPD patients. Intensive Care Med 1995;21(11): 871-879.
    • (1995) Intensive Care Med , vol.21 , Issue.11 , pp. 871-879
    • Nava, S.1    Bruschi, C.2    Rubini, F.3    Palo, A.4    Iotti, G.5    Braschi, A.6
  • 57
    • 0343893748 scopus 로고    scopus 로고
    • The Acute Respiratory Distress Syndrome Network
    • Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome
    • Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. The Acute Respiratory Distress Syndrome Network. N Engl J Med 2000;342(18):1301-1308.
    • (2000) N Engl J Med , vol.342 , Issue.18 , pp. 1301-1308
  • 58
    • 29744461101 scopus 로고    scopus 로고
    • Effects of tidal volume on work of breathing during lung-protective ventilation in patients with acute lung injury and acute respiratory distress syndrome
    • Kallet RH, Campbell AR, Dicker RA, Katz JA, Mackersie RC. Effects of tidal volume on work of breathing during lung-protective ventilation in patients with acute lung injury and acute respiratory distress syndrome. Crit Care Med 2006;34(1):8-14.
    • (2006) Crit Care Med , vol.34 , Issue.1 , pp. 8-14
    • Kallet, R.H.1    Campbell, A.R.2    Dicker, R.A.3    Katz, J.A.4    Mackersie, R.C.5
  • 59
    • 0031596438 scopus 로고    scopus 로고
    • The use of continuous i.v. sedation is associated with prolongation of mechanical ventilation
    • Kollef MH, Levy NT, Ahrens TS, Schaiff R, Prentice D, Sherman G. The use of continuous i.v. sedation is associated with prolongation of mechanical ventilation. Chest 1998;114(2):541-548.
    • (1998) Chest , vol.114 , Issue.2 , pp. 541-548
    • Kollef, M.H.1    Levy, N.T.2    Ahrens, T.S.3    Schaiff, R.4    Prentice, D.5    Sherman, G.6
  • 60
    • 44849095542 scopus 로고    scopus 로고
    • Randomized trial comparing daily interruption of sedation and nursing-implemented sedation algorithm in medical intensive care unit patients
    • de Wit M, Gennings C, Jenvey WI, Epstein SK. Randomized trial comparing daily interruption of sedation and nursing-implemented sedation algorithm in medical intensive care unit patients. Crit Care 2008;12(3):R70.
    • (2008) Crit Care , vol.12 , Issue.3
    • de Wit, M.1    Gennings, C.2    Jenvey, W.I.3    Epstein, S.K.4
  • 61
    • 0033400647 scopus 로고    scopus 로고
    • Effect of a nursing-implemented sedation protocol on the duration of mechanical ventilation
    • Brook AD, Ahrens TS, Schaiff R, Prentice D, Sherman G, Shannon W, et al. Effect of a nursing-implemented sedation protocol on the duration of mechanical ventilation. Crit Care Med 1999;27(12):2609-2615.
    • (1999) Crit Care Med , vol.27 , Issue.12 , pp. 2609-2615
    • Brook, A.D.1    Ahrens, T.S.2    Schaiff, R.3    Prentice, D.4    Sherman, G.5    Shannon, W.6
  • 62
    • 0034682246 scopus 로고    scopus 로고
    • Daily interruption of sedative infusions in critically ill patients undergoing mechanical ventilation
    • Kress JP, Pohlman AS, O'Connor MF, Hall JB. Daily interruption of sedative infusions in critically ill patients undergoing mechanical ventilation. N Engl J Med 2000;342(20):1471-1477.
    • (2000) N Engl J Med , vol.342 , Issue.20 , pp. 1471-1477
    • Kress, J.P.1    Pohlman, A.S.2    O'Connor, M.F.3    Hall, J.B.4
  • 63
    • 33748765536 scopus 로고    scopus 로고
    • A randomized, controlled trial of the role of weaning predictors in clinical decision-making
    • Tanios MA, Nevins ML, Hendra KP, Cardinal P, Allan JE, Naumova EN, et al. A randomized, controlled trial of the role of weaning predictors in clinical decision-making. Crit Care Med 2006;34(10): 2530-2535.
    • (2006) Crit Care Med , vol.34 , Issue.10 , pp. 2530-2535
    • Tanios, M.A.1    Nevins, M.L.2    Hendra, K.P.3    Cardinal, P.4    Allan, J.E.5    Naumova, E.N.6
  • 64
    • 0025896865 scopus 로고
    • A prospective study of indexes predicting the outcome of trials of weaning from mechanical ventilation
    • Yang KL, Tobin MJ. A prospective study of indexes predicting the outcome of trials of weaning from mechanical ventilation. N Engl J Med 1991;324(21):1445-1450.
    • (1991) N Engl J Med , vol.324 , Issue.21 , pp. 1445-1450
    • Yang, K.L.1    Tobin, M.J.2
  • 65
    • 42649138647 scopus 로고    scopus 로고
    • Effect of pressure support ventilation and positive end expiratory pressure on the rapid shallow breathing index in intensive care unit patients
    • El-Khatib MF, Zeineldine SM, Jamaleddine GW. Effect of pressure support ventilation and positive end expiratory pressure on the rapid shallow breathing index in intensive care unit patients. Intensive Care Med 2008;34(3):505-510.
    • (2008) Intensive Care Med , vol.34 , Issue.3 , pp. 505-510
    • El-Khatib, M.F.1    Zeineldine, S.M.2    Jamaleddine, G.W.3
  • 67
    • 61449129687 scopus 로고    scopus 로고
    • Weaning from ventilatory support
    • Epstein SK. Weaning from ventilatory support. Curr Opin Crit Care 2009;15(1):36-43.
    • (2009) Curr Opin Crit Care , vol.15 , Issue.1 , pp. 36-43
    • Epstein, S.K.1
  • 68
    • 78651392359 scopus 로고    scopus 로고
    • Patient-ventilator trigger asynchrony during weaning from mechanical ventilation (abstract)
    • Tanios, M, Singh, N, Hassoun, P, Epstein, S. Patient-ventilator trigger asynchrony during weaning from mechanical ventilation (abstract). Am J Respir Crit Care Med 2002;165(Suppl):A687.
    • (2002) Am J Respir Crit Care Med , vol.165 , Issue.SUPPL
    • Tanios, M.1    Singh, N.2    Hassoun, P.3    Epstein, S.4
  • 69
    • 34548000548 scopus 로고
    • Prevalence of patient ventilator asynchrony in critically ill patients
    • Varon, J, Fromm, R, Rodarte, J, Reinoso, M. Prevalence of patient ventilator asynchrony in critically ill patients. Chest 1994;106(Suppl):141S.
    • (1994) Chest , vol.106 , Issue.SUPPL
    • Varon, J.1    Fromm, R.2    Rodarte, J.3    Reinoso, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.