메뉴 건너뛰기




Volumn 4, Issue 1, 2011, Pages 62-64

Noninvasive assessment of coronary artery disease: Anatomy, physiology, and clinical outcome

Author keywords

atherosclerotic plaque; computed tomography; coronary artery disease; ischemia; luminal stenosis; magnetic resonance imaging; noninvasive coronary angiography

Indexed keywords

ANGIOCARDIOGRAPHY; ATHEROSCLEROTIC PLAQUE; CLINICAL ASSESSMENT; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTED TOMOGRAPHY SCANNER; CORONARY ARTERY CIRCUMFLEX BRANCH; CORONARY ARTERY DISEASE; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; FRACTIONAL FLOW RESERVE; HEART MUSCLE REVASCULARIZATION; HIGH RISK PATIENT; HUMAN; INTERMETHOD COMPARISON; MAGNETIC RESONANCE ANGIOGRAPHY; MORTALITY; MULTIDETECTOR COMPUTED TOMOGRAPHY; MYOCARDIAL PERFUSION IMAGING; NON INVASIVE PROCEDURE; NUCLEAR MAGNETIC RESONANCE IMAGING; OUTCOME ASSESSMENT; PERCUTANEOUS CORONARY INTERVENTION; PREDICTIVE VALUE; PRIORITY JOURNAL; PROGNOSIS; REVIEW; SCORING SYSTEM; SIGNAL NOISE RATIO; THREE DIMENSIONAL IMAGING; TREATMENT PLANNING;

EID: 78651397484     PISSN: 1936878X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcmg.2010.11.002     Document Type: Editorial
Times cited : (6)

References (19)
  • 1
    • 78651395784 scopus 로고    scopus 로고
    • A prospective study for comparison of MR and CT imaging for detection of coronary artery stenosis
    • A. Hamdan, P. Asbach, and E. Wellnhofer A prospective study for comparison of MR and CT imaging for detection of coronary artery stenosis J Am Coll Cardiol Img 4 2011 50 61
    • (2011) J Am Coll Cardiol Img , vol.4 , pp. 50-61
    • Hamdan, A.1    Asbach, P.2    Wellnhofer, E.3
  • 2
    • 48849095173 scopus 로고    scopus 로고
    • Comprehensive assessment of coronary artery stenoses: Computed tomography coronary angiography versus conventional coronary angiography and correlation with fractional flow reserve in patients with stable angina
    • W.B. Meijboom, C.A. Van Mieghem, and N. van Pelt Comprehensive assessment of coronary artery stenoses: computed tomography coronary angiography versus conventional coronary angiography and correlation with fractional flow reserve in patients with stable angina J Am Coll Cardiol 52 2008 636 643
    • (2008) J Am Coll Cardiol , vol.52 , pp. 636-643
    • Meijboom, W.B.1    Van Mieghem, C.A.2    Van Pelt, N.3
  • 3
    • 77955066802 scopus 로고    scopus 로고
    • Fractional flow reserve versus angiography for guiding percutaneous coronary intervention in patients with multivessel coronary artery disease: 2-year follow-up of the FAME study
    • N.H. Pijls, W.F. Fearon, and P.A. Tonino Fractional flow reserve versus angiography for guiding percutaneous coronary intervention in patients with multivessel coronary artery disease: 2-year follow-up of the FAME study J Am Coll Cardiol 56 2010 177 184
    • (2010) J Am Coll Cardiol , vol.56 , pp. 177-184
    • Pijls, N.H.1    Fearon, W.F.2    Tonino, P.A.3
  • 5
    • 34247113737 scopus 로고    scopus 로고
    • Optimal medical therapy with or without PCI for stable coronary disease
    • COURAGE Trial Research Group
    • W.E. Boden, R.A. O'Rourke, K.K. Teo COURAGE Trial Research Group Optimal medical therapy with or without PCI for stable coronary disease N Engl J Med 356 2007 1503 1516
    • (2007) N Engl J Med , vol.356 , pp. 1503-1516
    • Boden, W.E.1    O'Rourke, R.A.2    Teo, K.K.3
  • 7
    • 77956530771 scopus 로고    scopus 로고
    • Magnetic resonance coronary angiography: The condemned live longer
    • E. Nagel Magnetic resonance coronary angiography: the condemned live longer J Am Coll Cardiol 56 2010 992 994
    • (2010) J Am Coll Cardiol , vol.56 , pp. 992-994
    • Nagel, E.1
  • 8
    • 39349085553 scopus 로고    scopus 로고
    • MR-IMPACT: Comparison of perfusion-cardiac magnetic resonance with single-photon emission computed tomography for the detection of coronary artery disease in a multicentre, multivendor, randomized trial
    • J. Schwitter, C.M. Wacker, and A.C. van Rossum MR-IMPACT: comparison of perfusion-cardiac magnetic resonance with single-photon emission computed tomography for the detection of coronary artery disease in a multicentre, multivendor, randomized trial Eur Heart J 29 2008 480 489
    • (2008) Eur Heart J , vol.29 , pp. 480-489
    • Schwitter, J.1    Wacker, C.M.2    Van Rossum, A.C.3
  • 9
    • 34247282700 scopus 로고    scopus 로고
    • Prognostic value of cardiac magnetic resonance stress tests: Adenosine stress perfusion and dobutamine stress wall motion imaging
    • C. Jahnke, E. Nagel, and R. Gebker Prognostic value of cardiac magnetic resonance stress tests: adenosine stress perfusion and dobutamine stress wall motion imaging Circulation 115 2007 1769 1776
    • (2007) Circulation , vol.115 , pp. 1769-1776
    • Jahnke, C.1    Nagel, E.2    Gebker, R.3
  • 10
    • 33746408724 scopus 로고    scopus 로고
    • Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis
    • DOI 10.1001/jama.296.4.403
    • M.J. Garcia, J. Lessick, M.H. Hoffmann CATSCAN Study Investigators Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis JAMA 296 2006 403 411 (Pubitemid 44127524)
    • (2006) Journal of the American Medical Association , vol.296 , Issue.4 , pp. 403-411
    • Garcia, M.J.1    Lessick, J.2    Hoffmann, M.H.K.3
  • 11
    • 76349094438 scopus 로고    scopus 로고
    • Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition
    • S. Achenbach, M. Marwan, and D. Ropers Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition Eur Heart J 31 2010 340 346
    • (2010) Eur Heart J , vol.31 , pp. 340-346
    • Achenbach, S.1    Marwan, M.2    Ropers, D.3
  • 12
    • 70349774691 scopus 로고    scopus 로고
    • Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: Comparison of results with cardiac catheterization in a head-to-head pilot investigation
    • M. Dewey, E. Zimmermann, and F. Deissenrieder Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: comparison of results with cardiac catheterization in a head-to-head pilot investigation Circulation 120 2009 867 875
    • (2009) Circulation , vol.120 , pp. 867-875
    • Dewey, M.1    Zimmermann, E.2    Deissenrieder, F.3
  • 13
    • 68549088465 scopus 로고    scopus 로고
    • Impact of a reduced tube voltage on CT angiography and radiation dose: Results of the PROTECTION i Study
    • B. Bischoff, F. Hein, and T. Meyer Impact of a reduced tube voltage on CT angiography and radiation dose: results of the PROTECTION I Study J Am Coll Cardiol Img 2 2009 940 946
    • (2009) J Am Coll Cardiol Img , vol.2 , pp. 940-946
    • Bischoff, B.1    Hein, F.2    Meyer, T.3
  • 14
    • 77956832667 scopus 로고    scopus 로고
    • Adaptive statistical estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: The ERASIR study
    • J. Leipsic, T.M. LaBounty, and B. Heilbron Adaptive statistical estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study AJR Am J Roentgenol 195 2010 655 661
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 655-661
    • Leipsic, J.1    Labounty, T.M.2    Heilbron, B.3
  • 15
    • 34548500144 scopus 로고    scopus 로고
    • Prognostic value of multidetector coronary computed tomographic angiography for prediction of all-cause mortality
    • J.K. Min, L.J. Shaw, and R.B. Devereux Prognostic value of multidetector coronary computed tomographic angiography for prediction of all-cause mortality J Am Coll Cardiol 50 2007 1161 1170
    • (2007) J Am Coll Cardiol , vol.50 , pp. 1161-1170
    • Min, J.K.1    Shaw, L.J.2    Devereux, R.B.3
  • 16
    • 77956625311 scopus 로고    scopus 로고
    • Stress and rest dynamic myocardial perfusion imaging by evaluation of complete time-attenuation curves with dual-source CT
    • K.T. Ho, K.C. Chua, E. Klotz, and C. Panknin Stress and rest dynamic myocardial perfusion imaging by evaluation of complete time-attenuation curves with dual-source CT J Am Coll Cardiol Img 3 2010 811 820
    • (2010) J Am Coll Cardiol Img , vol.3 , pp. 811-820
    • Ho, K.T.1    Chua, K.C.2    Klotz, E.3    Panknin, C.4
  • 17
    • 78651395984 scopus 로고    scopus 로고
    • ACRIN Seeking Sites for Cardiac Imaging Trial http://www.acr.org/ SecondaryMainMenuCategories/NewsPublications/FeaturedCategories/CurrentACRNews/ ACRINAwardedGrantAHRQ.aspx 2010
    • (2010) ACRIN Seeking Sites for Cardiac Imaging Trial


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.