메뉴 건너뛰기




Volumn 100, Issue 2, 2011, Pages 188-192

Prevention of retinopathy of prematurity in preterm infants through changes in clinical practice and SpO2 technology

Author keywords

Hyperoxemia; Laser surgery; Newborns; Oxygen therapy; Prevention; Pulse oximetry saturation; Retinopathy of prematurity (ROP); Signal extraction technology (SET)

Indexed keywords

ARTICLE; BIRTH WEIGHT; CLINICAL PRACTICE; DISEASE ASSOCIATION; DISEASE SEVERITY; EYE EXAMINATION; FEMALE; GESTATIONAL AGE; HUMAN; LOW LEVEL LASER THERAPY; MAJOR CLINICAL STUDY; MALE; NEWBORN; NEWBORN INTENSIVE CARE; OXYGEN TENSION; PREMATURITY; PRIORITY JOURNAL; PULSE OXIMETRY; RETROLENTAL FIBROPLASIA; RISK REDUCTION;

EID: 78651365432     PISSN: 08035253     EISSN: 16512227     Source Type: Journal    
DOI: 10.1111/j.1651-2227.2010.02001.x     Document Type: Article
Times cited : (36)

References (30)
  • 2
    • 33947308503 scopus 로고    scopus 로고
    • Retinopathy of prematurity
    • Chen J, Smith LE,. Retinopathy of prematurity. Angiogenesis 2007; 10: 133-40.
    • (2007) Angiogenesis , vol.10 , pp. 133-140
    • Chen, J.1    Smith, L.E.2
  • 3
    • 17444395224 scopus 로고    scopus 로고
    • Incidence, risk factors of retinopathy of prematurity among very low birth weight infants in Singapore
    • Shah VA, Yeo CL, Ling YL, Ho LY,. Incidence, risk factors of retinopathy of prematurity among very low birth weight infants in Singapore. Ann Acad Med Singapore 2005; 34: 169-78.
    • (2005) Ann Acad Med Singapore , vol.34 , pp. 169-178
    • Shah, V.A.1    Yeo, C.L.2    Ling, Y.L.3    Ho, L.Y.4
  • 4
    • 0036913925 scopus 로고    scopus 로고
    • Incidence of retinopathy of prematurity in very-low-birth-weight infants born at Kalafong Hospital, Pretoria
    • Delport SD, Swanepoel JC, Odendaal PJ, Roux P,. Incidence of retinopathy of prematurity in very-low-birth-weight infants born at Kalafong Hospital, Pretoria. S Afr Med J 2002; 92: 986-90.
    • (2002) S Afr Med J , vol.92 , pp. 986-990
    • Delport, S.D.1    Swanepoel, J.C.2    Odendaal, P.J.3    Roux, P.4
  • 5
    • 0030996389 scopus 로고    scopus 로고
    • Racial variation in retinopathy of prematurity. The Cryotherapy for Retinopathy of Prematurity Cooperative Group
    • Saunders RA, Donahue ML, Christmann LM, Pakalnis AV, Tung B, Hardy RJ, et al. Racial variation in retinopathy of prematurity. The Cryotherapy for Retinopathy of Prematurity Cooperative Group. Arch Ophthalmol 1997; 115: 604-8.
    • (1997) Arch Ophthalmol , vol.115 , pp. 604-608
    • Saunders, R.A.1    Donahue, M.L.2    Christmann, L.M.3    Pakalnis, A.V.4    Tung, B.5    Hardy, R.J.6
  • 6
    • 0344441357 scopus 로고    scopus 로고
    • Pathogenesis of retinopathy of prematurity
    • Smith LE,. Pathogenesis of retinopathy of prematurity. Semin Neonatol 2003; 8: 469-73.
    • (2003) Semin Neonatol , vol.8 , pp. 469-473
    • Smith, L.E.1
  • 7
    • 26444610321 scopus 로고    scopus 로고
    • Retinopathy of prematurity and risk factors: A prospective cohort study
    • Karna P, Muttineni J, Angell L, Karmaus W,. Retinopathy of prematurity and risk factors: a prospective cohort study. BMC Pediatr 2005; 28: 5.
    • (2005) BMC Pediatr , vol.28 , pp. 5
    • Karna, P.1    Muttineni, J.2    Angell, L.3    Karmaus, W.4
  • 8
    • 1642527952 scopus 로고    scopus 로고
    • Arterial oxygen fluctuation and retinopathy of prematurity in very-low-birth-weight infants
    • York JR, Landers S, Kirby RS, Arbogast PG, Penn JS,. Arterial oxygen fluctuation and retinopathy of prematurity in very-low-birth-weight infants. J Perinatol 2004; 24: 82-7.
    • (2004) J Perinatol , vol.24 , pp. 82-87
    • York, J.R.1    Landers, S.2    Kirby, R.S.3    Arbogast, P.G.4    Penn, J.S.5
  • 9
    • 0037312997 scopus 로고    scopus 로고
    • Can changes in clinical practice decrease the incidence of severe retinopathy of prematurity in very low birth weight infants?
    • for the CSMC Oxygen Administration Study Group.
    • Chow LC, Wright KW, Sola A, for the CSMC Oxygen Administration Study Group. Can changes in clinical practice decrease the incidence of severe retinopathy of prematurity in very low birth weight infants? Pediatrics 2003; 111: 339-45.
    • (2003) Pediatrics , vol.111 , pp. 339-345
    • Chow, L.C.1    Wright, K.W.2    Sola, A.3
  • 10
    • 33750427876 scopus 로고    scopus 로고
    • Avoiding hyperoxia in infants ≤ 1,250 g is associated with improved short- and long-term outcomes
    • Deulofeut R, Critz A, Adams-Chapman I, Sola A,. Avoiding hyperoxia in infants ≤ 1,250 g is associated with improved short- and long-term outcomes. J Perinatol 2006; 26: 700-5.
    • (2006) J Perinatol , vol.26 , pp. 700-705
    • Deulofeut, R.1    Critz, A.2    Adams-Chapman, I.3    Sola, A.4
  • 12
    • 61349125462 scopus 로고    scopus 로고
    • A change in oxygen supplementation can decrease the incidence of retinopathy of prematurity
    • Sears JE, Pietz J, Sonnie C, Dolcini D, Hoppe G,. A change in oxygen supplementation can decrease the incidence of retinopathy of prematurity. Ophthalmol 2009; 116: 513-8.
    • (2009) Ophthalmol , vol.116 , pp. 513-518
    • Sears, J.E.1    Pietz, J.2    Sonnie, C.3    Dolcini, D.4    Hoppe, G.5
  • 13
    • 77953068229 scopus 로고    scopus 로고
    • High or low oxygen saturation and severe retinopathy of prematurity: A meta-analysis
    • Chen ML, Guo L, Smith LE, Dammann CE, Dammann O,. High or low oxygen saturation and severe retinopathy of prematurity: a meta-analysis. Pediatrics 2010; 125: 1483-92.
    • (2010) Pediatrics , vol.125 , pp. 1483-1492
    • Chen, M.L.1    Guo, L.2    Smith, L.E.3    Dammann, C.E.4    Dammann, O.5
  • 14
    • 77952784840 scopus 로고    scopus 로고
    • Target ranges of oxygen saturation in extremely preterm infants
    • SUPPORT Study Group.
    • SUPPORT Study Group. Target ranges of oxygen saturation in extremely preterm infants. NEJM 2010; 362: 1959-69.
    • (2010) NEJM , vol.362 , pp. 1959-1969
  • 15
    • 34250682084 scopus 로고    scopus 로고
    • Treatment-by-gender effect when aiming to avoid hyperoxia in preterm infants in the NICU
    • Deulofeut R, Golde D, Augusto S,. Treatment-by-gender effect when aiming to avoid hyperoxia in preterm infants in the NICU. Acta Paediatr 2007; 96: 990-4.
    • (2007) Acta Paediatr , vol.96 , pp. 990-994
    • Deulofeut, R.1    Golde, D.2    Augusto, S.3
  • 16
    • 0033869570 scopus 로고    scopus 로고
    • False alarms in very low birthweight infants: Comparison between three intensive care monitoring systems
    • Ahlborn V, Bohnhorst B,. False alarms in very low birthweight infants: comparison between three intensive care monitoring systems. Acta Paediatr 2000; 89: 571-6.
    • (2000) Acta Paediatr , vol.89 , pp. 571-576
    • Ahlborn, V.1    Bohnhorst, B.2
  • 17
    • 0034072367 scopus 로고    scopus 로고
    • Pulse oximeters' reliability in detecting hypoxemia and bradycardia: Comparison between a conventional and two new generation oximeters
    • Bohnhorst B, Peter CS, Owitz CF,. Pulse oximeters' reliability in detecting hypoxemia and bradycardia: comparison between a conventional and two new generation oximeters. Crit Care Med 2000; 28: 1565-8.
    • (2000) Crit Care Med , vol.28 , pp. 1565-1568
    • Bohnhorst, B.1    Peter, C.S.2    Owitz, C.F.3
  • 18
    • 0034085167 scopus 로고    scopus 로고
    • False alarms and sensitivity of conventional pulse oximetry versus the Masimo SET technology in the pediatric postanesthesia care unit
    • Malviya S, Reynolds PI, Voepel-Lewis T, Siewert M, Watson D, Tait AR, et al. False alarms and sensitivity of conventional pulse oximetry versus the Masimo SET technology in the pediatric postanesthesia care unit. Anesth Analg 2000; 90: 1336-40.
    • (2000) Anesth Analg , vol.90 , pp. 1336-1340
    • Malviya, S.1    Reynolds, P.I.2    Voepel-Lewis, T.3    Siewert, M.4    Watson, D.5    Tait, A.R.6
  • 19
    • 0036137803 scopus 로고    scopus 로고
    • Pulse oximetry in the neonatal care unit. Detection of hyperoxemia and false alarm rates
    • Poets CF, Urschitz MS, Bohnhorst B,. Pulse oximetry in the neonatal care unit. Detection of hyperoxemia and false alarm rates. Anesth Analg 2002; 94 (Suppl): S41-3.
    • (2002) Anesth Analg , vol.94 , Issue.SUPPL.
    • Poets, C.F.1    Urschitz, M.S.2    Bohnhorst, B.3
  • 20
    • 0036342147 scopus 로고    scopus 로고
    • Reliability of conventional and new oximetry in neonatal patients
    • Hay WW, Rodden DJ,. Reliability of conventional and new oximetry in neonatal patients. J Perinatol 2002; 22: 360-6.
    • (2002) J Perinatol , vol.22 , pp. 360-366
    • Hay, W.W.1    Rodden, D.J.2
  • 21
    • 0036138047 scopus 로고    scopus 로고
    • Advantages of new technology pulse oximetry with adults in extremis
    • Durbin CG, Rostow SK,. Advantages of new technology pulse oximetry with adults in extremis. Anesth Analg 2002; 1 (Suppl): 81-3.
    • (2002) Anesth Analg , vol.1 , Issue.SUPPL. , pp. 81-83
    • Durbin, C.G.1    Rostow, S.K.2
  • 22
    • 0036342720 scopus 로고    scopus 로고
    • More reliable oximetry reduces the frequency of arterial blood gas analysis and hastens oxygen weaning after cardiac surgery: A prospective, randomized trial of the clinical impact of the new technology
    • Durbin CG, Rostow SK,. More reliable oximetry reduces the frequency of arterial blood gas analysis and hastens oxygen weaning after cardiac surgery: a prospective, randomized trial of the clinical impact of the new technology. Crit Care Med 2002; 30: 1735-40.
    • (2002) Crit Care Med , vol.30 , pp. 1735-1740
    • Durbin, C.G.1    Rostow, S.K.2
  • 23
    • 36448995736 scopus 로고    scopus 로고
    • Masimo - A new reliable noninvasive method of detecting oxygen saturation in critically ill
    • Murthy LCT, Goyal RM,. Masimo-a new reliable noninvasive method of detecting oxygen saturation in critically ill. Indian J Anaesth, 2005; 49: 133-6.
    • (2005) Indian J Anaesth , vol.49 , pp. 133-136
    • Murthy, L.C.T.1    Goyal, R.M.2
  • 24
    • 16544384530 scopus 로고    scopus 로고
    • Pulse oximetry in children with congenital heart disease: Effects of cardiopulmonary bypass and cyanosis
    • Torres A, Skender KM,. Pulse oximetry in children with congenital heart disease: effects of cardiopulmonary bypass and cyanosis. J Intensive Care Med 2004; 19: 229-34.
    • (2004) J Intensive Care Med , vol.19 , pp. 229-234
    • Torres, A.1    Skender, K.M.2
  • 26
    • 4143088341 scopus 로고    scopus 로고
    • A comparison of the failure times of pulse oximeters during blood pressure cuff-induced hypo perfusion in volunteers
    • Kawagishi T, Kanaya N, Nakawama M, Kurosawa S, Namiki A,. A comparison of the failure times of pulse oximeters during blood pressure cuff-induced hypo perfusion in volunteers. Anesth Analg 2004; 99: 793-6.
    • (2004) Anesth Analg , vol.99 , pp. 793-796
    • Kawagishi, T.1    Kanaya, N.2    Nakawama, M.3    Kurosawa, S.4    Namiki, A.5
  • 27
    • 0034861464 scopus 로고    scopus 로고
    • Section on Ophthalmology, American Academy of Ophthalmology, and American Association for Pediatric Ophthalmology and Strabismus. Screening examination of premature infants for retinopathy of prematurity
    • American Academy of Pediatrics.
    • American Academy of Pediatrics. Section on Ophthalmology, American Academy of Ophthalmology, and American Association for Pediatric Ophthalmology and Strabismus. Screening examination of premature infants for retinopathy of prematurity. Pediatrics 2001; 108: 809-11.
    • (2001) Pediatrics , vol.108 , pp. 809-811
  • 28
    • 43049102750 scopus 로고    scopus 로고
    • Clinical practices in neonatal oxygenation: Where have we failed? What can we do?
    • Sola A, Saldeño YP, Favareto V,. Clinical practices in neonatal oxygenation: where have we failed? What can we do? J Perinatol 2008; 28 (Suppl 1): S28-34.
    • (2008) J Perinatol , vol.28 , Issue.SUPPL. 1
    • Sola, A.1    Saldeño, Y.P.2    Favareto, V.3
  • 29
    • 0026579684 scopus 로고
    • A cohort study of transcutaneous oxygen tension and the incidence and severity of retinopathy of prematurity
    • Flynn JT, Bancalari E, Snyder ES,. A cohort study of transcutaneous oxygen tension and the incidence and severity of retinopathy of prematurity. NEJM 1992; 326: 1050-4.
    • (1992) NEJM , vol.326 , pp. 1050-1054
    • Flynn, J.T.1    Bancalari, E.2    Snyder, E.S.3
  • 30
    • 44449153664 scopus 로고    scopus 로고
    • Pulse oxygen saturation levels and arterial oxygen tension values in newborns receiving oxygen therapy in the neonatal intensive care unit: Is 85% to 93% an acceptable range?
    • Castillo A, Sola A, Baquero H, Neira F, Alvis R, Deulofeut R, et al. Pulse oxygen saturation levels and arterial oxygen tension values in newborns receiving oxygen therapy in the neonatal intensive care unit: is 85% to 93% an acceptable range? Pediatrics 2008; 121: 882-9.
    • (2008) Pediatrics , vol.121 , pp. 882-889
    • Castillo, A.1    Sola, A.2    Baquero, H.3    Neira, F.4    Alvis, R.5    Deulofeut, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.