False alarms and sensitivity of conventional pulse oximetry versus the Masimo SET(TM) technology in the pediatric postanesthesia care unit

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CHILD; ELECTROCARDIOGRAM; HUMAN; INCIDENCE; MAJOR CLINICAL STUDY; PEDIATRIC ANESTHESIA; PRIORITY JOURNAL; PULSE OXIMETRY; TECHNOLOGY;

EID: 0034085167     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1097/00000539-200006000-00013     Document Type: Article
Times cited : (67)

References (17)
  • 2
    • 0025083581 scopus 로고
    • Hypoxaemia during postoperative recovery using continuous pulse oximetry
    • Brown LT, Purcell GJ, Traugott FM. Hypoxaemia during postoperative recovery using continuous pulse oximetry. Anaesth Intens Care 1990;18:509-16.
    • (1990) Anaesth Intens Care , vol.18 , pp. 509-516
    • Brown, L.T.1    Purcell, G.J.2    Traugott, F.M.3
  • 3
    • 0027415093 scopus 로고
    • Randomized evaluation of pulse oximetry in 20,802 patients: II
    • Moller JT, Johannessen NW, Espersen K, et al. Randomized evaluation of pulse oximetry in 20,802 patients: II. Anesthesiology 1993;78:445-53.
    • (1993) Anesthesiology , vol.78 , pp. 445-453
    • Moller, J.T.1    Johannessen, N.W.2    Espersen, K.3
  • 4
    • 0023551777 scopus 로고
    • Blood flow limits and pulse oximetry signal detection
    • Lawson D, Norley I, Korbon G. Blood flow limits and pulse oximetry signal detection. Anesthesiology 1987;67:599-603.
    • (1987) Anesthesiology , vol.67 , pp. 599-603
    • Lawson, D.1    Norley, I.2    Korbon, G.3
  • 5
    • 0025170596 scopus 로고
    • Pulse oximeter failure thresholds in hypotension and vasoconstriction
    • Severinghaus JW, Spellman MJ Jr. Pulse oximeter failure thresholds in hypotension and vasoconstriction. Anesthesiology 1990; 73:532-7.
    • (1990) Anesthesiology , vol.73 , pp. 532-537
    • Severinghaus, J.W.1    Spellman M.J., Jr.2
  • 6
    • 0025461541 scopus 로고
    • Conscious sedation and pulse oximetry: False alarms
    • Wilson S. Conscious sedation and pulse oximetry: false alarms. Pediatr Dent 1990;12:228-32.
    • (1990) Pediatr Dent , vol.12 , pp. 228-232
    • Wilson, S.1
  • 7
    • 0028946818 scopus 로고
    • Evaluation of the influence of movement on saturation readings from pulse oximeters
    • Plummer JL, Zakaria AZ, Ilsley AH, et al. Evaluation of the influence of movement on saturation readings from pulse oximeters. Anaesthesia 1995;50:423-6.
    • (1995) Anaesthesia , vol.50 , pp. 423-426
    • Plummer, J.L.1    Zakaria, A.Z.2    Ilsley, A.H.3
  • 8
    • 0028337587 scopus 로고
    • Postanesthesia monitoring revisited: Incidence of true and false alarms from different monitoring devices
    • Wiklund L, Hok B, Stahl K, Jordeby-Jonsson A. Postanesthesia monitoring revisited: incidence of true and false alarms from different monitoring devices. J Clin Anesth 1994;67:182-8.
    • (1994) J Clin Anesth , vol.67 , pp. 182-188
    • Wiklund, L.1    Hok, B.2    Stahl, K.3    Jordeby-Jonsson, A.4
  • 9
    • 0031027017 scopus 로고    scopus 로고
    • The effects of motion on the performance of pulse oximeters in volunteers
    • Barker SJ, Shah NK. The effects of motion on the performance of pulse oximeters in volunteers. Anesthesiology 1997;86:101-8.
    • (1997) Anesthesiology , vol.86 , pp. 101-108
    • Barker, S.J.1    Shah, N.K.2
  • 10
    • 0030017260 scopus 로고    scopus 로고
    • Clinical evaluation of a prototype motion artifact resistant pulse oximeter in the recovery room
    • Dumas C, Wahr JA, Tremper KK. Clinical evaluation of a prototype motion artifact resistant pulse oximeter in the recovery room. Anesth Analg 1996;83:269-72.
    • (1996) Anesth Analg , vol.83 , pp. 269-272
    • Dumas, C.1    Wahr, J.A.2    Tremper, K.K.3
  • 11
    • 0028604544 scopus 로고
    • Intraoperative pulse oximetry: Frequency and distribution of discrepant data
    • Pan PH, Gravenstein N. Intraoperative pulse oximetry: frequency and distribution of discrepant data. J Clin Anesth 1994; 6:491-5.
    • (1994) J Clin Anesth , vol.6 , pp. 491-495
    • Pan, P.H.1    Gravenstein, N.2
  • 12
    • 0030841543 scopus 로고    scopus 로고
    • Influence of pulse oximeter lower alarm limit on the incidence of hypoxaemia in the recovery room
    • Rheineck-Leyssius AT, Kalkman CJ. Influence of pulse oximeter lower alarm limit on the incidence of hypoxaemia in the recovery room. Br J Anaesth 1997;79:460-4.
    • (1997) Br J Anaesth , vol.79 , pp. 460-464
    • Rheineck-Leyssius, A.T.1    Kalkman, C.J.2
  • 13
    • 0032053128 scopus 로고    scopus 로고
    • Influence of pulse oximeter settings on the frequency of alarms and detection of hypoxemia
    • Rheineck-Leyssius AT, Kalkman CJ. Influence of pulse oximeter settings on the frequency of alarms and detection of hypoxemia. J Clin Monit 1998;14:151-6.
    • (1998) J Clin Monit , vol.14 , pp. 151-156
    • Rheineck-Leyssius, A.T.1    Kalkman, C.J.2
  • 14
    • 0007702673 scopus 로고    scopus 로고
    • Effects of motion on the performance of thirteen pulse oximeters
    • Barker SJ, Morgan S, Brown B. Effects of motion on the performance of thirteen pulse oximeters [abstract]. Anesthesiology 1999;91:A581.
    • (1999) Anesthesiology , vol.91
    • Barker, S.J.1    Morgan, S.2    Brown, B.3
  • 15
    • 0028300877 scopus 로고
    • Crying wolf: False alarms in a pediatric intensive care unit
    • Lawless ST. Crying wolf: false alarms in a pediatric intensive care unit. Crit Care Med 1994;22:981-5.
    • (1994) Crit Care Med , vol.22 , pp. 981-985
    • Lawless, S.T.1
  • 16
    • 0000644003 scopus 로고    scopus 로고
    • Nurse's response to alarms from monitoring systems in the NICU
    • Sabar R, Zmora E. Nurse's response to alarms from monitoring systems in the NICU [abstract]. Pediatr Res 1997;41:147A.
    • (1997) Pediatr Res , vol.41
    • Sabar, R.1    Zmora, E.2
  • 17
    • 0029800442 scopus 로고    scopus 로고
    • Influence of motivation of care providers on the incidence of postoperative hypoxaemia in the recovery room
    • Rheineck-Leyssius AT, Kalkman CH, Trouwborst A. Influence of motivation of care providers on the incidence of postoperative hypoxaemia in the recovery room. Br J Anaesth 1996;77: 453-7.
    • (1996) Br J Anaesth , vol.77 , pp. 453-457
    • Rheineck-Leyssius, A.T.1    Kalkman, C.H.2    Trouwborst, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.