메뉴 건너뛰기




Volumn 24, Issue 2, 2011, Pages 213-218

Robotic renal transplantation: First European case

Author keywords

daVinci surgical system; kidney transplantation; laparoscopy; minimally invasive; robotic surgery; warm graft ischemia

Indexed keywords

ABDOMEN; ADULT; ANASTOMOSIS; ARTICLE; CASE REPORT; FEMALE; GRAFT PERFUSION; GRAFT RECIPIENT; HUMAN; INCISION; KIDNEY FUNCTION; KIDNEY ISCHEMIA; KIDNEY TRANSPLANTATION; LAPAROSCOPY; OPERATION DURATION; ORGAN DONOR; ORGAN TRANSPLANTATION; PRIORITY JOURNAL; ROBOTICS; SURGICAL TECHNIQUE;

EID: 78651082843     PISSN: 09340874     EISSN: 14322277     Source Type: Journal    
DOI: 10.1111/j.1432-2277.2010.01191.x     Document Type: Article
Times cited : (93)

References (28)
  • 1
    • 70449215374 scopus 로고
    • Kidney transplantation between seven pairs of identical twins
    • Murray JE, Merrill JP, Harrison JH,. Kidney transplantation between seven pairs of identical twins. Ann Surg 1958; 148: 343.
    • (1958) Ann Surg , vol.148 , pp. 343
    • Murray, J.E.1    Merrill, J.P.2    Harrison, J.H.3
  • 4
    • 39149132118 scopus 로고    scopus 로고
    • A consensus document on robotic surgery
    • The SAGES-MIRA Robotic Surgery Consensus Group.
    • Herron DM, Marohn M, The SAGES-MIRA Robotic Surgery Consensus Group. A consensus document on robotic surgery. Surg Endosc 2008; 22: 313.
    • (2008) Surg Endosc , vol.22 , pp. 313
    • Herron, D.M.1    Marohn, M.2
  • 6
    • 77952306346 scopus 로고    scopus 로고
    • Beating heart totally endoscopic coronary artery bypass
    • Srivastava S, Gadasalli S, Agusala M, et al. Beating heart totally endoscopic coronary artery bypass. Ann Thorac Surg 2010; 89: 1873.
    • (2010) Ann Thorac Surg , vol.89 , pp. 1873
    • Srivastava, S.1    Gadasalli, S.2    Agusala, M.3
  • 7
    • 0036847189 scopus 로고    scopus 로고
    • Robot-assisted laparoscopic aortobifemoral bypass for aortoiliac occlusive disease: A report of two cases
    • Wisselink W, Cuesta MA, Gracia C, Rauwerda JA,. Robot-assisted laparoscopic aortobifemoral bypass for aortoiliac occlusive disease: a report of two cases. J Vasc Surg 2002; 36: 1079.
    • (2002) J Vasc Surg , vol.36 , pp. 1079
    • Wisselink, W.1    Cuesta, M.A.2    Gracia, C.3    Rauwerda, J.A.4
  • 10
    • 32044466197 scopus 로고    scopus 로고
    • Haptic interaction in robot-assisted endoscopic surgery: A sensorized end-effector
    • Tavakoli M, Patel RV, Moallem M,. Haptic interaction in robot-assisted endoscopic surgery: a sensorized end-effector. Int J Med Robot 2005; 1: 53.
    • (2005) Int J Med Robot , vol.1 , pp. 53
    • Tavakoli, M.1    Patel, R.V.2    Moallem, M.3
  • 11
    • 34248525932 scopus 로고    scopus 로고
    • A pneumatic haptic feedback actuator array for robotic surgery of simulation
    • King CH, Higa AT, Culjat MO, et al. A pneumatic haptic feedback actuator array for robotic surgery of simulation. Stud Health Technol Inform 2007; 125: 217.
    • (2007) Stud Health Technol Inform , vol.125 , pp. 217
    • King, C.H.1    Higa, A.T.2    Culjat, M.O.3
  • 12
    • 67651244385 scopus 로고    scopus 로고
    • The value of haptic feedback in conventional and robot-assisted minimal invasive surgery and virtual reality training: A current review
    • Van der Meijden OAJ, Schijven MP,. The value of haptic feedback in conventional and robot-assisted minimal invasive surgery and virtual reality training: a current review. Surg Endosc 2009; 23: 1180.
    • (2009) Surg Endosc , vol.23 , pp. 1180
    • Van Der Meijden, O.A.J.1    Schijven, M.P.2
  • 13
    • 43749116472 scopus 로고    scopus 로고
    • Visual clues act as a substitute for haptic feedback in robotic surgery
    • Hagen ME, Meehan JJ, Inan I, Morel P,. Visual clues act as a substitute for haptic feedback in robotic surgery. Surg Endosc 2008; 22: 1505.
    • (2008) Surg Endosc , vol.22 , pp. 1505
    • Hagen, M.E.1    Meehan, J.J.2    Inan, I.3    Morel, P.4
  • 14
    • 36549075117 scopus 로고    scopus 로고
    • Da Vinci robot error and failure rates: Single institution experience on a single three-arm robot unit of more than 700 consecutive robot-assisted laparoscopic radical prostatectomies
    • Zorn KC, Gofrit ON, Orvieto MA, et al. Da Vinci robot error and failure rates: single institution experience on a single three-arm robot unit of more than 700 consecutive robot-assisted laparoscopic radical prostatectomies. J Endourol 2007; 21: 1341.
    • (2007) J Endourol , vol.21 , pp. 1341
    • Zorn, K.C.1    Gofrit, O.N.2    Orvieto, M.A.3
  • 15
    • 0036126743 scopus 로고    scopus 로고
    • Robotic assisted kidney transplantation: An initial experience
    • Hoznek A, Zaki SK, Samadi DB, et al. Robotic assisted kidney transplantation: an initial experience. J Urol 2002; 167: 1604.
    • (2002) J Urol , vol.167 , pp. 1604
    • Hoznek, A.1    Zaki, S.K.2    Samadi, D.B.3
  • 16
    • 77952924252 scopus 로고    scopus 로고
    • Robotic transabdominal kidney transplantation in a morbidly obese patient
    • Giulianotti P, Gorodner V, Sbrana F, et al. Robotic transabdominal kidney transplantation in a morbidly obese patient. Am J Transplant 2010; 10: 1478.
    • (2010) Am J Transplant , vol.10 , pp. 1478
    • Giulianotti, P.1    Gorodner, V.2    Sbrana, F.3
  • 18
    • 79955929718 scopus 로고    scopus 로고
    • Renal paratransplant hernia: A surgical complication of kidney transplantation
    • published on line April 22,; DOI: 10.1007/s00423-010-0648-8
    • Gao ZL, Zhao JJ, Sun DK, Yang DD, Wang L, Shi L,. Renal paratransplant hernia: a surgical complication of kidney transplantation. Langenbecks Arch Surg, published on line April 22, 2010; DOI: 10.1007/s00423-010-0648-8.
    • (2010) Langenbecks Arch Surg
    • Gao, Z.L.1    Zhao, J.J.2    Sun, D.K.3    Yang, D.D.4    Wang, L.5    Shi, L.6
  • 19
    • 0033557272 scopus 로고    scopus 로고
    • Acute torsion of the renal transplant after combined kidney-pancreas transplant
    • Roza AM, Johnson CP, Adams M,. Acute torsion of the renal transplant after combined kidney-pancreas transplant. Transplantation 1999; 67: 486.
    • (1999) Transplantation , vol.67 , pp. 486
    • Roza, A.M.1    Johnson, C.P.2    Adams, M.3
  • 20
    • 0030339850 scopus 로고    scopus 로고
    • Effective surface cooling of the kidney during vascular anastomosis decreases the risk of delayed kidney function after transplantation
    • Szostek M, Pacholczyk M, Lagiewska B, Danielewicz R, Walaszwski J, Rowinski W,. Effective surface cooling of the kidney during vascular anastomosis decreases the risk of delayed kidney function after transplantation. Transpl Int 1996; 9 (Suppl. 1): S84.
    • (1996) Transpl Int , vol.9 , Issue.SUPPL. 1
    • Szostek, M.1    Pacholczyk, M.2    Lagiewska, B.3    Danielewicz, R.4    Walaszwski, J.5    Rowinski, W.6
  • 21
    • 0038748063 scopus 로고    scopus 로고
    • Kidney warming during transplantation
    • Feuillu B, Cormier L, Frimat L, et al. Kidney warming during transplantation. Transpl Int 2003; 16: 307.
    • (2003) Transpl Int , vol.16 , pp. 307
    • Feuillu, B.1    Cormier, L.2    Frimat, L.3
  • 23
    • 0027315846 scopus 로고
    • A cooling jacket to reduce renal damage during transplantation
    • Stephenson RN,. A cooling jacket to reduce renal damage during transplantation. Br J Urol 1993; 71: 384.
    • (1993) Br J Urol , vol.71 , pp. 384
    • Stephenson, R.N.1
  • 24
    • 0031781293 scopus 로고    scopus 로고
    • The laparoscopic cooling sheath: Novel device for hypothermic preservation of kidney during temporary renal artery occlusion
    • Herrell SD, Jahoda AE, Husain AN, Albala DM,. The laparoscopic cooling sheath: novel device for hypothermic preservation of kidney during temporary renal artery occlusion. J Endourol 1998; 12: 155.
    • (1998) J Endourol , vol.12 , pp. 155
    • Herrell, S.D.1    Jahoda, A.E.2    Husain, A.N.3    Albala, D.M.4
  • 25
    • 39149136869 scopus 로고    scopus 로고
    • Evaluation of the ischemic protection efficacy of a laparoscopic renal cooling device using renal transplantation viability assessment criteria in a porcine model
    • Navarro AP, Sohrabi S, Colechin E, Griffiths C, Talbot D, Soomro NA,. Evaluation of the ischemic protection efficacy of a laparoscopic renal cooling device using renal transplantation viability assessment criteria in a porcine model. J Urol 2008; 179: 1184.
    • (2008) J Urol , vol.179 , pp. 1184
    • Navarro, A.P.1    Sohrabi, S.2    Colechin, E.3    Griffiths, C.4    Talbot, D.5    Soomro, N.A.6
  • 26
    • 51249098295 scopus 로고    scopus 로고
    • Minimal skin incision in living kidney transplantation
    • Park SC, Kim SD, Kim JI, Moon IS,. Minimal skin incision in living kidney transplantation. Transplant Proc 2008; 40: 2347.
    • (2008) Transplant Proc , vol.40 , pp. 2347
    • Park, S.C.1    Kim, S.D.2    Kim, J.I.3    Moon, I.S.4
  • 27
    • 33750932347 scopus 로고    scopus 로고
    • Minimally invasive kidney transplantation: The first experience
    • Øyen O, Scholz T, Hartmann A, Pfeffer P,. Minimally invasive kidney transplantation: the first experience. Transplant Proc 2006; 38: 2798.
    • (2006) Transplant Proc , vol.38 , pp. 2798
    • Øyen, O.1    Scholz, T.2    Hartmann, A.3    Pfeffer, P.4
  • 28
    • 34447248733 scopus 로고    scopus 로고
    • Minimally invasive video-assisted kidney transplantation (MIVAKT)
    • Mun SP, Chnag JH, Kim KJ, et al. Minimally invasive video-assisted kidney transplantation (MIVAKT). J Surg Res 2007; 141: 204.
    • (2007) J Surg Res , vol.141 , pp. 204
    • Mun, S.P.1    Chnag, J.H.2    Kim, K.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.