메뉴 건너뛰기




Volumn 13, Issue 4, 2010, Pages 189-196

A new pulse duplicator with a passive fill ventricle for analysis of cardiac dynamics

Author keywords

Arterial compliance; E max; Heart function; P V diagram; Pulse duplicator; Ventricular assist device (VAD)

Indexed keywords

ARTICLE; BLOOD PUMP; COMPLIANCE (PHYSICAL); DIASTOLE; DYNAMICS; HEART ASSIST DEVICE; HEART FAILURE; HEART VENTRICLE; HYDRODYNAMICS; PRIORITY JOURNAL; PULSE DUPLICATOR; SIMULATION; SYSTOLE; VALIDATION PROCESS;

EID: 78650950369     PISSN: 14347229     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10047-010-0518-8     Document Type: Article
Times cited : (23)

References (16)
  • 1
    • 9444238864 scopus 로고
    • A hydraulic analog of the systemic and pulmonary circulation for testing artificial hearts
    • Reul H, Minamitani H, Runge J. A hydraulic analog of the systemic and pulmonary circulation for testing artificial hearts. Proceeding ESAO2 (1975);120-27.
    • (1975) Proceeding ESAO2 , pp. 120-127
    • Reul, H.1    Minamitani, H.2    Runge, J.3
  • 2
    • 18744366137 scopus 로고    scopus 로고
    • Design and in vitro performance of a novel bileaflet mechanical heart valve prosthesis
    • D Medeart C Schmitz G Rau H Reul 2005 Design and in vitro performance of a novel bileaflet mechanical heart valve prosthesis Int J Artif Organs 28 256 263
    • (2005) Int J Artif Organs , vol.28 , pp. 256-263
    • Medeart, D.1    Schmitz, C.2    Rau, G.3    Reul, H.4
  • 3
    • 0020858768 scopus 로고
    • Left ventricular interaction with arterial load studied in isolated canine heart
    • 6638199
    • WL Maughan D Burkhoff K Sunagawa 1983 Left ventricular interaction with arterial load studied in isolated canine heart Am J Physiol 245 H773 H780 6638199
    • (1983) Am J Physiol , vol.245
    • Maughan, W.L.1    Burkhoff, D.2    Sunagawa, K.3
  • 4
    • 0031937479 scopus 로고    scopus 로고
    • A computer controlled mock circulatory system for mono- and biventricular assist device testing
    • 1:STN:280:DyaK1c3htlGntw%3D%3D 9554823
    • G Ferrari C De Lazzari R Mimmo G Tosti D Ambrosi K Gorczynska 1998 A computer controlled mock circulatory system for mono- and biventricular assist device testing Int J Artif Organs 21 26 36 1:STN:280:DyaK1c3htlGntw%3D%3D 9554823
    • (1998) Int J Artif Organs , vol.21 , pp. 26-36
    • Ferrari, G.1    De Lazzari, C.2    Mimmo, R.3    Tosti, G.4    Ambrosi, D.5    Gorczynska, K.6
  • 5
    • 0348230939 scopus 로고    scopus 로고
    • Characterization of an Adult Mock Circulation for Testing Cardiac Support Devices
    • DOI 10.1097/01.MAT.0000104818.70726.E6
    • GM Pantalos SC Koenig KJ Gillars GA Giridharan DL Ewert 2004 Characterization of an adult mock circulation for testing for cardiac support devices ASAIO J 50 1 37 46 10.1097/01.MAT.0000104818.70726.E6 14763490 (Pubitemid 38063999)
    • (2004) ASAIO Journal , vol.50 , Issue.1 , pp. 37-46
    • Pantalos, G.M.1    Koenig, S.C.2    Gillars, K.J.3    Giridharan, G.A.4    Ewert, D.L.5
  • 6
    • 0346059626 scopus 로고    scopus 로고
    • Hemodynamic and Pressure-Volume Responses to Continuous and Pulsatile Ventricular Assist in an Adult Mock Circulation
    • DOI 10.1097/01.MAT.0000104816.50277.EB
    • SC Koenig GM Pantalos KJ Gillars DL Ewert KN Litwak SW Etoch 2004 Hemodynamic and pressure-volume responses to continuous and pulsatile ventricular assist in adult mock circulation ASAIO J 50 15 24 10.1097/01.MAT.0000104816.50277.EB 14763487 (Pubitemid 38063996)
    • (2004) ASAIO Journal , vol.50 , Issue.1 , pp. 15-24
    • Koenig, S.C.1    Pantalos, G.M.2    Gillars, K.J.3    Ewert, D.L.4    Litwak, K.N.5    Etoch, S.W.6
  • 7
    • 2442599564 scopus 로고    scopus 로고
    • HEART: An automated beat-to-beat cardiovascular analysis package using Matlab®
    • DOI 10.1016/S0010-4825(03)00087-8, PII S0010482503000878
    • MJ Schroeder B Perrault DL Ewert SC Koenig 2004 HEART: an automated beat-to-beat cardiovascular analysis package using Matlab Comput Biol Med 34 5 371 388 10.1016/S0010-4825(03)00087-8 15145710 (Pubitemid 38625607)
    • (2004) Computers in Biology and Medicine , vol.34 , Issue.5 , pp. 371-388
    • Schroeder, M.J.1    Perreault, B.2    Ewert, D.L.3    Koenig, S.C.4    Perreault, W.G.5
  • 8
    • 59649124611 scopus 로고    scopus 로고
    • A modified elastance model to control mock ventricles in real time: Numerical and experimental validation
    • 10.1097/MAT.0b013e31818a5c93 19033767
    • FM Colacino F Moscato F Piedimonte G Danieli S Nicosia M Arabia 2008 A modified elastance model to control mock ventricles in real time: numerical and experimental validation ASAIO J 54 563 573 10.1097/MAT.0b013e31818a5c93 19033767
    • (2008) ASAIO J , vol.54 , pp. 563-573
    • Colacino, F.M.1    Moscato, F.2    Piedimonte, F.3    Danieli, G.4    Nicosia, S.5    Arabia, M.6
  • 9
    • 0016280920 scopus 로고
    • Instantaneous pressure-volume relationships and their ratio in the excised supported canine left ventricle
    • 1:STN:280:DyaE2c3ntFOhtA%3D%3D 4841253
    • H Suga K Sagawa 1974 Instantaneous pressure-volume relationships and their ratio in the excised supported canine left ventricle Circ Res 35 117 126 1:STN:280:DyaE2c3ntFOhtA%3D%3D 4841253
    • (1974) Circ Res , vol.35 , pp. 117-126
    • Suga, H.1    Sagawa, K.2
  • 10
    • 0019493375 scopus 로고
    • Pusher-Plate Type TAH system operated in the left and right free-running variable rate mode
    • 1:STN:280:DyaL3M3otFWhtw%3D%3D 10.1111/j.1525-1594.1981.tb03975.x 7271526
    • S Takatani H Harasaki S Suwa S Murabaryashi R Sukalac G Jacobs R Kiraly Y Nose 1981 Pusher-Plate Type TAH system operated in the left and right free-running variable rate mode Artif Organs 5 2 132 142 1:STN:280: DyaL3M3otFWhtw%3D%3D 10.1111/j.1525-1594.1981.tb03975.x 7271526
    • (1981) Artif Organs , vol.5 , Issue.2 , pp. 132-142
    • Takatani, S.1    Harasaki, H.2    Suwa, S.3    Murabaryashi, S.4    Sukalac, R.5    Jacobs, G.6    Kiraly, R.7    Nose, Y.8
  • 11
    • 38049174902 scopus 로고    scopus 로고
    • A reproduction of inflow restriction in the mock circulatory system to evaluate a hydrodynamic performance of a ventricular assist device in practical conditions
    • 10.1007/978-3-540-74771-0-63
    • M Furusato T Shima Y Kokuzawa K Ito T Tanaka K Iwasaki Y Qian M Umezu Z Yan L Zhu 2007 A reproduction of inflow restriction in the mock circulatory system to evaluate a hydrodynamic performance of a ventricular assist device in practical conditions Life Syst Model Simul 4689 553 558 10.1007/978-3-540-74771- 0-63
    • (2007) Life Syst Model Simul , vol.4689 , pp. 553-558
    • Furusato, M.1    Shima, T.2    Kokuzawa, Y.3    Ito, K.4    Tanaka, T.5    Iwasaki, K.6    Qian, Y.7    Umezu, M.8    Yan, Z.9    Zhu, L.10
  • 14
    • 0021277724 scopus 로고
    • Effect of arterial impedance changes on the end-systolic pressure-volume relation
    • 1:STN:280:DyaL2c3gs1SitQ%3D%3D 6723003
    • WL Maughan K Sunagawa D Burkhoff K Sagawa 1984 Effect of arterial impedance changes on the end-systolic pressure-volume relation Circ Res 54 595 602 1:STN:280:DyaL2c3gs1SitQ%3D%3D 6723003
    • (1984) Circ Res , vol.54 , pp. 595-602
    • Maughan, W.L.1    Sunagawa, K.2    Burkhoff, D.3    Sagawa, K.4
  • 15
    • 0034744380 scopus 로고    scopus 로고
    • Elastance-based control of a mock circulatory system
    • DOI 10.1114/1.1355275
    • LA Baloa JR Boston F Antaki 2001 Elastance-based control of a mock circulatory system Ann Biomed Eng 29 244 251 1:STN:280:DC%2BD3M3hvVantQ%3D%3D 10.1114/1.1355275 11310786 (Pubitemid 32380953)
    • (2001) Annals of Biomedical Engineering , vol.29 , Issue.3 , pp. 244-251
    • Baloa, L.A.1    Boston, J.R.2    Antaki, J.F.3
  • 16
    • 34247568038 scopus 로고    scopus 로고
    • Left ventricular pressure-volume loop analysis during continuous cardiac assist in acute animal trials
    • DOI 10.1111/j.1525-1594.2007.00394.x
    • F Moscato M Vollkron H Bergmeister G Wieselthaler E Leonard H Schima 2007 Left ventricular pressure-volume loop analysis during continuous cardiac assist in acute animal trials Artif Organs 31 369 376 10.1111/j.1525-1594.2007.00394.x 17470206 (Pubitemid 46669026)
    • (2007) Artificial Organs , vol.31 , Issue.5 , pp. 369-376
    • Moscato, F.1    Vollkron, M.2    Bergmeister, H.3    Wieselthaler, G.4    Leonard, E.5    Schima, H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.