메뉴 건너뛰기




Volumn 38, Issue 1, 2011, Pages 390-396

Feasibility of using cone-beam CT to verify and reposition the optically guided target localization of linear accelerator based stereotactic radiosurgery

Author keywords

cone beam CT (CBCT); optical guided target localization; quality assurance; Stereotactic radiosurgery

Indexed keywords

BIREFRINGENCE; CALIBRATION; ERRORS; LINEAR ACCELERATORS; METADATA; PHANTOMS; QUALITY ASSURANCE; RADIOTHERAPY;

EID: 78650890408     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3531547     Document Type: Article
Times cited : (5)

References (9)
  • 2
    • 0031692287 scopus 로고    scopus 로고
    • Optic-guided stereotactic radiotherapy
    • DOI 10.1016/S0958-3947(98)00017-X, PII S095839479800017X
    • F. J. Bova, S. L. Meeks, W. A. Friedman, and J. M. Buatti, " Optical guided stereotactic radiotherapy.," Med. Dosim. 0739-0211 23 (3), 221-228 (1998). 10.1016/S0958-3947(98)00017-X (Pubitemid 28463079)
    • (1998) Medical Dosimetry , vol.23 , Issue.3 , pp. 221-228
    • Bova, F.J.1    Meeks, S.L.2    Friedman, W.A.3    Buatti, J.M.4
  • 3
    • 0026458588 scopus 로고
    • Radiosurgery target point alignment errors detected with portal film verification
    • 0360-3016, 10.1016/0360-3016(92)90728-Z
    • C. F. Serago, " Radiosurgery target point alignment errors detected with portal film verification.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 24, 777-780 (1992). 10.1016/0360-3016(92)90728-Z
    • (1992) Int. J. Radiat. Oncol., Biol., Phys. , vol.24 , pp. 777-780
    • Serago, C.F.1
  • 4
    • 0036680147 scopus 로고    scopus 로고
    • Flat-panel cone-beam computed tomography for image-guided radiation therapy
    • DOI 10.1016/S0360-3016(02)02884-5, PII S0360301602028845
    • D. A. Jaffray, J. H. Siewerdsen, J. W. Wong, and A. A. Martinez, " Flat-panel cone-beam computer tomography image-guided radiation therapy.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 53, 1337-1349 (2002). 10.1016/S0360-3016(02)02884-5 (Pubitemid 34787872)
    • (2002) International Journal of Radiation Oncology Biology Physics , vol.53 , Issue.5 , pp. 1337-1349
    • Jaffray, D.A.1    Siewerdsen, J.H.2    Wong, J.W.3    Martinez, A.A.4
  • 5
    • 17844380035 scopus 로고    scopus 로고
    • Accurate technique for complete geometric calibration of cone-beam computed tomography systems
    • DOI 10.1118/1.1869652
    • Y. Cho, D. J. Mosely, J. H. Siewerdsen, and D. A. Jaffray, " Accurate technique for complete geometric calibration of cone-beam computed tomography systems.," Med. Phys. 0094-2405 32, 968-983 (2005). 10.1118/1.1869652 (Pubitemid 40586782)
    • (2005) Medical Physics , vol.32 , Issue.4 , pp. 968-983
    • Cho, Y.1    Moseley, D.J.2    Siewerdsen, J.H.3    Jaffray, D.A.4
  • 6
    • 19944432829 scopus 로고    scopus 로고
    • Low-dose megavoltage cone-beam CT for radiation therapy
    • 0360-3016, 10.1016/j.ijrob2004.10.011
    • J. Pouliot, " Low-dose megavoltage cone-beam CT for radiation therapy.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 61, 552-560 (2005). 10.1016/j.ijrobp.2004.10.011
    • (2005) Int. J. Radiat. Oncol., Biol., Phys. , vol.61 , pp. 552-560
    • Pouliot, J.1
  • 8
    • 22544436952 scopus 로고    scopus 로고
    • Intracranial stereotactic positioning systems: Report of the American Association of Physicists in Medicine Radiation Therapy Committee Task Group No. 68
    • DOI 10.1118/1.1945347
    • A. W. Lightstone, S. H. Benedict, F. J. Bova, T. D. Solberg, and R. L. Stern, " Intracranial stereotactic positioning systems: Report of the American Association of Physicists in Medicine Radiation Therapy Committee Task Group No. 68.," Med. Phys. 0094-2405 32, 2380-2398 (2005). 10.1118/1.1945347 (Pubitemid 41023199)
    • (2005) Medical Physics , vol.32 , Issue.7 , pp. 2380-2398
    • Lightstone, A.W.1    Benedict, S.H.2    Bova, F.J.3    Solberg, T.D.4    Stern, R.L.5
  • 9
    • 34447303103 scopus 로고    scopus 로고
    • Accuracy and feasibility of cone-beam computed tomography for stereotactic radiosurgery setup
    • DOI 10.1118/1.2731031
    • J. Chang, K. M. Yenice, A. Narayana, and P. H. Gutin, " Accuracy and feasibility of cone-beam computed tomography for stereotactic radiosurgery setup.," Med. Phys. 0094-2405 34, 2077-2084 (2007). 10.1118/1.2731031 (Pubitemid 47055743)
    • (2007) Medical Physics , vol.34 , Issue.6 , pp. 2077-2084
    • Chang, J.1    Yenice, K.M.2    Narayana, A.3    Gutin, P.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.