메뉴 건너뛰기




Volumn 44, Issue 1, 2011, Pages 45-53

A multi-target screening analysis in human plasma using fast liquid chromatography-hybrid tandem mass spectrometry (Part II)

Author keywords

Drugs; LC MS MS; Library; Remedi ; Screening; Toxicology

Indexed keywords

ANTIDEPRESSANT AGENT; BENZODIAZEPINE DERIVATIVE; TOXIC SUBSTANCE;

EID: 78650880759     PISSN: 00099120     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinbiochem.2010.07.019     Document Type: Article
Times cited : (24)

References (18)
  • 1
    • 0024340050 scopus 로고
    • Automated liquid chromatographic analysis of drugs in urine by on-line sample cleanup and isocratic multi-column separation
    • Binder S.R., Regalia M., Biaggi-McEachem M. Automated liquid chromatographic analysis of drugs in urine by on-line sample cleanup and isocratic multi-column separation. Chromatogr A 1989, 473:325-341.
    • (1989) Chromatogr A , vol.473 , pp. 325-341
    • Binder, S.R.1    Regalia, M.2    Biaggi-McEachem, M.3
  • 2
    • 0035000381 scopus 로고    scopus 로고
    • Comprehensive drug screening by integrated use of gas chromatography/mass spectrometry and remedi HS
    • Valli A., Polettini A., Papa P., Montagna M. Comprehensive drug screening by integrated use of gas chromatography/mass spectrometry and remedi HS. Ther Drug Monit 2001, 23:287-294.
    • (2001) Ther Drug Monit , vol.23 , pp. 287-294
    • Valli, A.1    Polettini, A.2    Papa, P.3    Montagna, M.4
  • 3
    • 78650871191 scopus 로고    scopus 로고
    • DPS and UBZ Drug Library Listing Releases 4.3X.35/5.3X.33/5.1X.33.
    • Remedi™ HS, DPS and UBZ Drug Library Listing Releases 4.3X.35/5.3X.33/5.1X.33.
    • Remedi™, H.S.1
  • 4
    • 0034795407 scopus 로고    scopus 로고
    • Tuning compounds for electrospray ionization/in source collision-induced dissociation and mass spectra library searching
    • Weinmann W., Stoertzel M., Vogt S., Svoboda M., Schreiber A. Tuning compounds for electrospray ionization/in source collision-induced dissociation and mass spectra library searching. J Mass Spectrom 2001, 36:1013-1023.
    • (2001) J Mass Spectrom , vol.36 , pp. 1013-1023
    • Weinmann, W.1    Stoertzel, M.2    Vogt, S.3    Svoboda, M.4    Schreiber, A.5
  • 5
    • 0035839165 scopus 로고    scopus 로고
    • Tune compounds for electrospray ionization/in-source collision-induced dissociation with mass spectral library searching
    • Weinmann W., Stoertzel M., Vogt S., Wendt J. Tune compounds for electrospray ionization/in-source collision-induced dissociation with mass spectral library searching. J Chromatogr A 2001, 926:199-209.
    • (2001) J Chromatogr A , vol.926 , pp. 199-209
    • Weinmann, W.1    Stoertzel, M.2    Vogt, S.3    Wendt, J.4
  • 6
    • 0034446045 scopus 로고    scopus 로고
    • In-source CID mass spectral libraries for thegeneral unknownscreening of drugs and toxicants
    • Marquet P., Venisse N., Lacassie E., Lachâtre G. In-source CID mass spectral libraries for thegeneral unknownscreening of drugs and toxicants. Analusis 2000, 28:925-934.
    • (2000) Analusis , vol.28 , pp. 925-934
    • Marquet, P.1    Venisse, N.2    Lacassie, E.3    Lachâtre, G.4
  • 7
    • 0033984691 scopus 로고    scopus 로고
    • Application of spectral libraries for high-performance liquid chromatography-atmospheric pressure ionisation mass spectrometry to the analysis of pesticide and explosive residues in environmental samples
    • Schreiber A., Efer J., Engelwald W. Application of spectral libraries for high-performance liquid chromatography-atmospheric pressure ionisation mass spectrometry to the analysis of pesticide and explosive residues in environmental samples. J Chromatogr A 2000, 869:411-425.
    • (2000) J Chromatogr A , vol.869 , pp. 411-425
    • Schreiber, A.1    Efer, J.2    Engelwald, W.3
  • 8
    • 0142043007 scopus 로고    scopus 로고
    • Simultaneous screening for 238 drugs in blood by liquid chromatography-ionspray tandem mass spectrometry with multiple-reaction monitoring
    • Gergov M., Ojanperä I., Vuori E. Simultaneous screening for 238 drugs in blood by liquid chromatography-ionspray tandem mass spectrometry with multiple-reaction monitoring. J Chromatogr B 2003, 795:41-53.
    • (2003) J Chromatogr B , vol.795 , pp. 41-53
    • Gergov, M.1    Ojanperä, I.2    Vuori, E.3
  • 9
    • 0037702325 scopus 로고    scopus 로고
    • Evaluation of an improved general unknown screening procedure using liquid-chromatography-electrospray-mass spectrometry by comparison with gas chromatography and high-performance liquid-chromatography-diode array detection
    • Saint-Marcoux F., Lachâtre G., Marquet P. Evaluation of an improved general unknown screening procedure using liquid-chromatography-electrospray-mass spectrometry by comparison with gas chromatography and high-performance liquid-chromatography-diode array detection. J Am Soc Mass Spectrom 2003, 14(1):14-22.
    • (2003) J Am Soc Mass Spectrom , vol.14 , Issue.1 , pp. 14-22
    • Saint-Marcoux, F.1    Lachâtre, G.2    Marquet, P.3
  • 10
    • 0033799309 scopus 로고    scopus 로고
    • Evaluation of automated single mass spectrometry to tandem mass spectrometry function switching for comprehensive drug profiling analysis using a quadrupole timme-of-flight mass spectrometer
    • Decaestecker T.N., Clauwaert K.M., Van Bocxlear J.F., et al. Evaluation of automated single mass spectrometry to tandem mass spectrometry function switching for comprehensive drug profiling analysis using a quadrupole timme-of-flight mass spectrometer. Rapid Commun Mass Spectrom 2000, 14:1787-1792.
    • (2000) Rapid Commun Mass Spectrom , vol.14 , pp. 1787-1792
    • Decaestecker, T.N.1    Clauwaert, K.M.2    Van Bocxlear, J.F.3
  • 11
    • 2542434283 scopus 로고    scopus 로고
    • Comparison of product ion spectra obtained by liquid chromatography/triple-quadrupole mass spectrometry for library search
    • Gergov M., Weinmann W., Meriluoto J., Uusitalo J., Ojanperä I. Comparison of product ion spectra obtained by liquid chromatography/triple-quadrupole mass spectrometry for library search. Rapid Commun Mass Spectrom 2004, 18:1039-1046.
    • (2004) Rapid Commun Mass Spectrom , vol.18 , pp. 1039-1046
    • Gergov, M.1    Weinmann, W.2    Meriluoto, J.3    Uusitalo, J.4    Ojanperä, I.5
  • 14
    • 19544366418 scopus 로고    scopus 로고
    • Development of a multi-target screening analysis for 301 drugs using a QTrap liquid chromatography/tandem mass spectrometry system and automated library searching
    • Mueller C.A., Weinmann W., Dressen S., Schreiber A., Gergov M. Development of a multi-target screening analysis for 301 drugs using a QTrap liquid chromatography/tandem mass spectrometry system and automated library searching. Rapid Commun Mass Spectrom 2005, 19:1332-1338.
    • (2005) Rapid Commun Mass Spectrom , vol.19 , pp. 1332-1338
    • Mueller, C.A.1    Weinmann, W.2    Dressen, S.3    Schreiber, A.4    Gergov, M.5
  • 15
    • 29144511543 scopus 로고    scopus 로고
    • Investigation of an LC-MS-MS (QTrap) method for the rapid screening and identification of drugs in postmortem toxicology whole blood samples
    • Herrin G.L., McCurdy H.H., Wall W.H. Investigation of an LC-MS-MS (QTrap) method for the rapid screening and identification of drugs in postmortem toxicology whole blood samples. J Anal Toxicol 2005, 29:599-606.
    • (2005) J Anal Toxicol , vol.29 , pp. 599-606
    • Herrin, G.L.1    McCurdy, H.H.2    Wall, W.H.3
  • 16
    • 70349125897 scopus 로고    scopus 로고
    • X-Rank: a robust algorithm for small molecule identification using tandem mass spectrometry
    • Mylonas R., Mauron Y., Masselot A., Binz P.A., Budin N., Fathi M., et al. X-Rank: a robust algorithm for small molecule identification using tandem mass spectrometry. Anal Chem 2009, 81:7604-7610.
    • (2009) Anal Chem , vol.81 , pp. 7604-7610
    • Mylonas, R.1    Mauron, Y.2    Masselot, A.3    Binz, P.A.4    Budin, N.5    Fathi, M.6
  • 18
    • 0035885289 scopus 로고    scopus 로고
    • Simultaneous screening and quantitation of 18 antihistamine drugs in blood by liquid chromatography ionspray tandem mass spectrometry
    • Gergov M., Robson J.N., Ojanperä I., Heinonen O.P., Vuori E. Simultaneous screening and quantitation of 18 antihistamine drugs in blood by liquid chromatography ionspray tandem mass spectrometry. Forensic Sci Int 2001, 121:108-115.
    • (2001) Forensic Sci Int , vol.121 , pp. 108-115
    • Gergov, M.1    Robson, J.N.2    Ojanperä, I.3    Heinonen, O.P.4    Vuori, E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.