메뉴 건너뛰기




Volumn 29, Issue 7, 2005, Pages 599-606

Investigation of an LC-MS-MS (QTrap®) method for the rapid screening and identification of drugs in postmortem toxicology whole blood samples

Author keywords

[No Author keywords available]

Indexed keywords

ACEBUTOLOL; ALPRAZOLAM; AMFEBUTAMONE; AMITRIPTYLINE; AMOXAPINE; AMPHETAMINE; ATOMOXETINE; BENZATROPINE; BENZOYLECGONINE; BROMPHENIRAMINE; BUPIVACAINE; BUSPIRONE; CAFFEINE; CARBAMAZEPINE; CARBINOXAMINE; CARISOPRODOL; CHLORDIAZEPOXIDE; CHLORPHENIRAMINE; CHLORPROMAZINE; CHLORPROTHIXENE; CITALOPRAM; CLOBAZAM; CLOMIPRAMINE; CLONIDINE; CLOZAPINE; COCAINE; HOMOCOCAINE; MORPHINE 6 ACETATE; PARACETAMOL; UNINDEXED DRUG;

EID: 29144511543     PISSN: 01464760     EISSN: 01464760     Source Type: Journal    
DOI: 10.1093/jat/29.7.599     Document Type: Article
Times cited : (65)

References (15)
  • 1
    • 0035882754 scopus 로고    scopus 로고
    • Methodology for the development of a drug library based upon collisioninduced fragmentation for the identification of toxicologically relevant drugs in plasma samples
    • A. Lips, W. Lameijer, R.H. Fokkens, and N. Nibbering. Methodology for the development of a drug library based upon collisioninduced fragmentation for the identification of toxicologically relevant drugs in plasma samples. J. Chomatogr. B 759: 191-207 (2001).
    • (2001) J. Chomatogr. B , vol.759 , pp. 191-207
    • Lips, A.1    Lameijer, W.2    Fokkens, R.H.3    Nibbering, N.4
  • 2
    • 0035095696 scopus 로고    scopus 로고
    • Screening method for seventy psychoactive drugs of drug metabolites in serum based on high performance liquid chromatography-electrospray ionization mass spectrometry
    • M. Rittner, F. Pragst, and J. Neuman. Screening method for seventy psychoactive drugs of drug metabolites in serum based on high performance liquid chromatography-electrospray ionization mass spectrometry. J. Anal. Toxicol . 25: 115-124 (2001).
    • (2001) J. Anal. Toxicol . , vol.25 , pp. 115-124
    • Rittner, M.1    Pragst, F.2    Neuman, J.3
  • 3
    • 0033941267 scopus 로고    scopus 로고
    • Automated liquid chromatographic/tandem mass spectrometric method for screening ß-blocking drugs in urine
    • M. Gergov, J.N. Robson, and E. Duchoslav. Automated liquid chromatographic/tandem mass spectrometric method for screening ß-blocking drugs in urine. J. Mass Spectrom. 35: 912-918 (2000).
    • (2000) J. Mass Spectrom. , vol.35 , pp. 912-918
    • Gergov, M.1    Robson, J.N.2    Duchoslav, E.3
  • 4
    • 29144508436 scopus 로고    scopus 로고
    • Identification of lorazepam and sildenafil as examples for the application of LC/ionspray-MS and MS-MS with mass spectra library searching in forensic toxicology
    • W. Weimann, N. Lehmann, C. Muller, A. Wiedemann, and M. Svoboda. Identification of lorazepam and sildenafil as examples for the application of LC/ionspray-MS and MS-MS with mass spectra library searching in forensic toxicology. Forensic Sci. Int. 844: 409-418 (1999).
    • (1999) Forensic Sci. Int. , vol.844 , pp. 409-418
    • Weimann, W.1    Lehmann, N.2    Muller, C.3    Wiedemann, A.4    Svoboda, M.5
  • 5
    • 0036146706 scopus 로고    scopus 로고
    • Is LC-MS suitable for a comprehensive screening of drugs and poisons in clinical toxicology?
    • P. Marquet. Is LC-MS suitable for a comprehensive screening of drugs and poisons in clinical toxicology? Ther. Drug Monit. 24: 125-133 (2002).
    • (2002) Ther. Drug Monit. , vol.24 , pp. 125-133
    • Marquet, P.1
  • 6
    • 0142043007 scopus 로고    scopus 로고
    • Simultaneous screening for 238 drugs in blood by liquid chromatography-ionspray tandem mass spectrometry with multiple-reaction monitoring
    • M. Gergov, I. Ojanperä, and E. Vuori. Simultaneous screening for 238 drugs in blood by liquid chromatography-ionspray tandem mass spectrometry with multiple-reaction monitoring. J. Chromatogr. B 795: 41-53 (2003).
    • (2003) J. Chromatogr. B , vol.795 , pp. 41-53
    • Gergov, M.1    Ojanperä, I.2    Vuori, E.3
  • 8
    • 0344886208 scopus 로고
    • Enzyme immunoassay: Novel approaches to tissue and fluid analysis
    • R.C. Baselt, Ed. Biomedical Publications, Foster City, CA
    • E.L. Slightom and H.H. McCurdy. Enzyme immunoassay: novel approaches to tissue and fluid analysis. In Advances in Forensic Toxicology, Vol. 1, R.C. Baselt, Ed. Biomedical Publications, Foster City, CA, 1984, pp 19-40.
    • (1984) Advances in Forensic Toxicology , vol.1 , pp. 19-40
    • Slightom, E.L.1    McCurdy, H.H.2
  • 9
    • 0023749946 scopus 로고
    • A novel procedure for the analysis of drugs in whole blood by homogeneous enzyme immunoassay (EMIT)
    • L.J. Lewellen and H.H. McCurdy. A novel procedure for the analysis of drugs in whole blood by homogeneous enzyme immunoassay (EMIT). J. Anal. Toxicol . 12: 260-264 (1988).
    • (1988) J. Anal. Toxicol. , vol.12 , pp. 260-264
    • Lewellen, L.J.1    McCurdy, H.H.2
  • 10
    • 0021330325 scopus 로고
    • Detection of drugs in saliva of impaired driver
    • H.W. Peel, B.J. Perrigo, and N.Z. Mikhael. Detection of drugs in saliva of impaired driver. J. Forensic Sci. 29: 185-189 (1984).
    • (1984) J. Forensic Sci. , vol.29 , pp. 185-189
    • Peel, H.W.1    Perrigo, B.J.2    Mikhael, N.Z.3
  • 11
    • 0037709383 scopus 로고    scopus 로고
    • Unique scanning capabilities of a new hybrid linear ion trap mass spectrometer (Q Trap) for high sensitivity proteomics application
    • J.C.Y. LeBlanc, J.W. Hager, A.M.P. Illisiu, C. Hunter, F. Zhong, and I. Chu. Unique scanning capabilities of a new hybrid linear ion trap mass spectrometer (Q Trap) for high sensitivity proteomics application. Proteomics 3: 859-869 (2003).
    • (2003) Proteomics , vol.3 , pp. 859-869
    • LeBlanc, J.C.Y.1    Hager, J.W.2    Illisiu, A.M.P.3    Hunter, C.4    Zhong, F.5    Chu, I.6
  • 12
    • 0037097063 scopus 로고    scopus 로고
    • Ion suppression effects in liquid-chromatography electospray ionization-region induced dissociation mass spectrometry with different serum extraction methods for systemic toxicological analysis with MS libraries
    • C. Muler, P. Schafer, M. Stortzel, S. Vogt, and W. Weinmann. Ion suppression effects in liquid-chromatography electospray ionization-region induced dissociation mass spectrometry with different serum extraction methods for systemic toxicological analysis with MS libraries. J. Chomatogr. B 773: 47-52 (2002).
    • (2002) J. Chomatogr. B , vol.773 , pp. 47-52
    • Muler, C.1    Schafer, P.2    Stortzel, M.3    Vogt, S.4    Weinmann, W.5
  • 13
    • 0142195729 scopus 로고    scopus 로고
    • Matrix effect in bio-analysis of illicit drugs with LC-MS/MS: Influence of ionization type, sample preparation, and biofluid
    • R. Diems, M.A. Huestis, W.E. Lambert, and C.M. Murphy. Matrix effect in bio-analysis of illicit drugs with LC-MS/MS: influence of ionization type, sample preparation, and biofluid. Am. Soc. Mass Spectrom. 14: 1290-1294 (2003).
    • (2003) Am. Soc. Mass Spectrom. , vol.14 , pp. 1290-1294
    • Diems, R.1    Huestis, M.A.2    Lambert, W.E.3    Murphy, C.M.4
  • 14
    • 5344275249 scopus 로고    scopus 로고
    • Confirmatory analysis of drugs of abuse in plasma and urine by high performamce liquid chromatography-tandem mass spectrometry with respect to criteria for compound identification
    • B. Maralikova and W. Wienmann. Confirmatory analysis of drugs of abuse in plasma and urine by high performamce liquid chromatography-tandem mass spectrometry with respect to criteria for compound identification. J. Chromatogr. B 811: 21-20 (2004).
    • (2004) J. Chromatogr. B , vol.811 , pp. 21-120
    • Maralikova, B.1    Wienmann, W.2
  • 15
    • 2642554857 scopus 로고    scopus 로고
    • 9-tetahydrocannabinol in human plasma by highperformance liquid chromatography/tandem mass spectrometry
    • 9-tetahydrocannabinol in human plasma by highperformance liquid chromatography/tandem mass spectrometry. J. Mass Spectrom. 39: 521-531 (2004).
    • (2004) J. Mass Spectrom. , vol.39 , pp. 521-531
    • Maralikova, B.1    Wienmann, W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.