메뉴 건너뛰기




Volumn , Issue , 2010, Pages 3073-3076

Automatic detection of luminal borders in IVUS images by magnitude-phase histograms of complex brushlet coefficients

Author keywords

[No Author keywords available]

Indexed keywords

AUTOMATIC DETECTION; BACK-SCATTERED; BLOOD REGION; DATA SETS; DEFORMABLE MODELS; HIGH FREQUENCY HF; HIGH FREQUENCY TRANSDUCERS; INTRAVASCULAR ULTRASOUND; LUMINAL BORDER; PHASE HISTOGRAM;

EID: 78650842945     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2010.5626135     Document Type: Conference Paper
Times cited : (16)

References (14)
  • 3
    • 44449128563 scopus 로고    scopus 로고
    • An automated methos for lumen and media-adventitia border detection in a sequence of IVUS frames
    • M. Plissiti, D. Fotidadis, L. Michalis, G. Bozios, "An Automated Methos for Lumen and Media-Adventitia Border Detection in a sequence of IVUS frames," IEEE Trans. Info. Tech. Biomed., Vol. 19, No. 10, pp. 996-1011, 2000.
    • (2000) IEEE Trans. Info. Tech. Biomed. , vol.19 , Issue.10 , pp. 996-1011
    • Plissiti, M.1    Fotidadis, D.2    Michalis, L.3    Bozios, G.4
  • 4
    • 33646399717 scopus 로고    scopus 로고
    • Intravascular ultrasound image segmentation: A three-dimensional fast-marching method based on gray level distribution
    • M. R. Cardinal, J. Meunier, G. Soulez, R. L. Maurice, E. Therasse, G. Cloutier, "Intravascular Ultrasound Image Segmentation: A Three-Dimensional Fast-Marching Method Based on Gray Level Distribution," IEEE. Trans. Med. Imag., Vol. 25, No. 5, pp. 590-601, 2006.
    • (2006) IEEE Trans. Med. Imag. , vol.25 , Issue.5 , pp. 590-601
    • Cardinal, M.R.1    Meunier, J.2    Soulez, G.3    Maurice, R.L.4    Therasse, E.5    Cloutier, G.6
  • 6
    • 0034601752 scopus 로고    scopus 로고
    • Feasibility of a novel blood reduction algorithm to enhance reproducibility of ultra-high-frequency intravascular ultrasound images
    • K. Hibi, A. Takagi, X. Zhang, T. T. Teo, H. N. Boneau, P. G. Yock, P. J. Fitzgerald, "Feasibility of a Novel Blood Reduction Algorithm to Enhance Reproducibility of Ultra-High-Frequency Intravascular Ultrasound Images," Circulation, Vol. 102, No. 14, pp. 1657-1663, 2000.
    • (2000) Circulation , vol.102 , Issue.14 , pp. 1657-1663
    • Hibi, K.1    Takagi, A.2    Zhang, X.3    Teo, T.T.4    Boneau, H.N.5    Yock, P.G.6    Fitzgerald, P.J.7
  • 7
    • 4143109438 scopus 로고    scopus 로고
    • Spatial aniosotropic diffusion and local time correlation applied to segmentation of vessels in ultrasound image sequences
    • S. Balocco, O. Basset, C. Cachard, P. Delachartre, "Spatial Aniosotropic Diffusion and Local Time Correlation Applied to Segmentation of Vessels in Ultrasound Image Sequences," IEEE Symp. Ultrasonics, Vol. 2, pp. 1549-1552, 2003.
    • (2003) IEEE Symp. Ultrasonics , vol.2 , pp. 1549-1552
    • Balocco, S.1    Basset, O.2    Cachard, C.3    Delachartre, P.4
  • 8
    • 38149064491 scopus 로고    scopus 로고
    • Blood detection in IVUS images for 3D volume of lumen changes measurement due to different drugs administration
    • CAIP
    • D. Rotger, P. Radeva, E. F. Nofrerias, J. Mauri, "Blood Detection in IVUS Images for 3D Volume of Lumen Changes Measurement Due to Different Drugs Administration," CAIP 2007, LNCS 4673, pp. 285-292.
    • (2007) LNCS , vol.4673 , pp. 285-292
    • Rotger, D.1    Radeva, P.2    Nofrerias, E.F.3    Mauri, J.4
  • 9
    • 84883843367 scopus 로고    scopus 로고
    • One-class acoustic characterization applied to blood detection in IVUS
    • MICCAI, Part I
    • S. M. O'Malley, M. Naghavi, I. A. Kakadiaris, "One-Class Acoustic Characterization Applied to Blood Detection in IVUS," MICCAI 2007, Part I, LNCS 4791, pp. 202-209.
    • (2007) LNCS , vol.4791 , pp. 202-209
    • O'malley, S.M.1    Naghavi, M.2    Kakadiaris, I.A.3
  • 12
    • 0035354203 scopus 로고    scopus 로고
    • LV volume quantification via spatio-temporal analysis of real-time 3D echocardiography
    • E. Angelini, A. Laine, S. Takuma, J. Holmes, S. Homma, "LV Volume Quantification via Spatio-Temporal Analysis of Real-Time 3D Echocardiography, " IEEE Trans. Med. Imag., Vol. 20, No. 6, pp. 457-469, 2001.
    • (2001) IEEE Trans. Med. Imag. , vol.20 , Issue.6 , pp. 457-469
    • Angelini, E.1    Laine, A.2    Takuma, S.3    Holmes, J.4    Homma, S.5
  • 13
    • 0000981459 scopus 로고    scopus 로고
    • Brushlets: A tool for directional image analysis and image compression
    • F. Meyer and R. R. Coifman, "Brushlets: A tool for directional image analysis and image compression," Applied and computational harmonic analysis, vol. 4, pp. 147-187, 1997.
    • (1997) Applied and Computational Harmonic Analysis , vol.4 , pp. 147-187
    • Meyer, F.1    Coifman, R.R.2
  • 14
    • 0001618573 scopus 로고
    • Local sine and cosine bases of coifman and meyer and the construction of smooth wavelets
    • Wavelet Analysis and its Applications, C. K. Chui, Ed. San Diego: Academic Press
    • P. Ausher, G. Weiss, M. V. Wickerhauser, "Local sine and cosine bases of Coifman and Meyer and the construction of smooth wavelets," in Wavelets-A tutorial in Theory and Application, vol. 2, Wavelet Analysis and its Applications, C. K. Chui, Ed. San Diego: Academic Press, 1992, pp. 237-256.
    • (1992) Wavelets-A Tutorial in Theory and Application , vol.2 , pp. 237-256
    • Ausher, P.1    Weiss, G.2    Wickerhauser, M.V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.