메뉴 건너뛰기




Volumn , Issue , 2009, Pages 471-474

Classification of blood regions in IVUS images using three dimensional brushlet expansions

Author keywords

[No Author keywords available]

Indexed keywords

FEATURE EXTRACTION; IMAGE CLASSIFICATION; SPECKLE;

EID: 77950963310     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2009.5334419     Document Type: Conference Paper
Times cited : (5)

References (16)
  • 2
    • 44449128563 scopus 로고    scopus 로고
    • An Automated Methos for Lumen and Media-Adventitia Border Detection in a sequence of IVUS frames
    • M. Plissiti, D. Fotidadis, L. Michalis, G. Bozios, "An Automated Methos for Lumen and Media-Adventitia Border Detection in a sequence of IVUS frames," IEEE Trans. Info. Tech. Biomed., Vol.19, No.10, pp. 996-1011, 2000.
    • (2000) IEEE Trans. Info. Tech. Biomed. , vol.19 , Issue.10 , pp. 996-1011
    • Plissiti, M.1    Fotidadis, D.2    Michalis, L.3    Bozios, G.4
  • 4
    • 33646399717 scopus 로고    scopus 로고
    • Intravascular Ultrasound Image Segmentation: A Three-Dimensional Fast- Marching Method Based on Gray Level Distribution
    • M. R. Cardinal, J. Meunier, G. Soulez, R. L. Maurice, E. Therasse, G. Cloutier, "Intravascular Ultrasound Image Segmentation: A Three-Dimensional Fast- Marching Method Based on Gray Level Distribution," IEEE. Trans. Med. Imag., Vol.25, No.5, pp. 590-601, 2006.
    • (2006) IEEE. Trans. Med. Imag. , vol.25 , Issue.5 , pp. 590-601
    • Cardinal, M.R.1    Meunier, J.2    Soulez, G.3    Maurice, R.L.4    Therasse, E.5    Cloutier, G.6
  • 6
    • 38149064491 scopus 로고    scopus 로고
    • Blood Detection in IVUS Images for 3D Volume of Lumen Changes Measurement Due to Different Drugs Administration
    • CAIP
    • D. Rotger, P. Radeva, E. F. Nofrerias, J. Mauri, "Blood Detection in IVUS Images for 3D Volume of Lumen Changes Measurement Due to Different Drugs Administration," CAIP 2007, LNCS 4673, pp. 285-292.
    • (2007) LNCS 4673 , pp. 285-292
    • Rotger, D.1    Radeva, P.2    Nofrerias, E.F.3    Mauri, J.4
  • 7
    • 0034601752 scopus 로고    scopus 로고
    • Feasibility of a Novel Blood Reduction Algorithm to Enhance Reproducibility of Ultra-High-Frequency Intravascular Ultrasound Images
    • K. Hibi, A. Takagi, X. Zhang, T. T. Teo, H. N. Boneau, P. G. Yock, P. J. Fitzgerald, "Feasibility of a Novel Blood Reduction Algorithm to Enhance Reproducibility of Ultra-High-Frequency Intravascular Ultrasound Images," Circulation, Vol.102, No.14, pp. 1657-1663, 2000.
    • (2000) Circulation , vol.102 , Issue.14 , pp. 1657-1663
    • Hibi, K.1    Takagi, A.2    Zhang, X.3    Teo, T.T.4    Boneau, H.N.5    Yock, P.G.6    Fitzgerald, P.J.7
  • 8
    • 84883843367 scopus 로고    scopus 로고
    • One-Class Acoustic Characterization Applied to Blood Detection in IVUS
    • MICCAI
    • S. M. O'Malley, M. Naghavi, I. A. Kakadiaris, "One-Class Acoustic Characterization Applied to Blood Detection in IVUS," MICCAI 2007, Part I, LNCS 4791, pp. 202-209.
    • (2007) LNCS 4791 , Issue.PART I , pp. 202-209
    • O'Malley, S.M.1    Naghavi, M.2    Kakadiaris, I.A.3
  • 9
    • 0000981459 scopus 로고    scopus 로고
    • Brushlets: A tool for directional image analysis and image compression
    • F. Meyer and R. R. Coifman, "Brushlets: A tool for directional image analysis and image compression," Applied and computational harmonic analysis, vol.4, pp. 147- 187, 1997.
    • (1997) Applied and Computational Harmonic Analysis , vol.4 , pp. 147-187
    • Meyer, F.1    Coifman, R.R.2
  • 11
    • 0035354203 scopus 로고    scopus 로고
    • LV Volume Quantification via Spatio-Temporal Analysis of Real-Time 3D Echocardiography
    • E. Angelini, A. Laine, S. Takuma, J. Holmes, S. Homma, "LV Volume Quantification via Spatio-Temporal Analysis of Real-Time 3D Echocardiography, " IEEE Trans. Med. Imag., Vol.20, No.6, pp. 457-469, 2001.
    • (2001) IEEE Trans. Med. Imag. , vol.20 , Issue.6 , pp. 457-469
    • Angelini, E.1    Laine, A.2    Takuma, S.3    Holmes, J.4    Homma, S.5
  • 12
    • 0037159282 scopus 로고    scopus 로고
    • Coronary Plaque Classification with Intravascular Ultrasound Radiofrequency Data Analysis
    • A. Nair, B. D. Kuban, M. Tuzcu, P. Schoenhagen, S. E. Nissen, D. G. Vince, "Coronary Plaque Classification With Intravascular Ultrasound Radiofrequency Data Analysis," Circulation, vol.106, no.17, pp. 2200-2206, 2002.
    • (2002) Circulation , vol.106 , Issue.17 , pp. 2200-2206
    • Nair, A.1    Kuban, B.D.2    Tuzcu, M.3    Schoenhagen, P.4    Nissen, S.E.5    Vince, D.G.6
  • 13
    • 44449167665 scopus 로고    scopus 로고
    • Challenges in Atherosclerotic Plaque Characterization with Intravascular Ultrasound (IVUS): From Data Collection to Classification
    • A. Katouzian, S. Sathyanarayana, B. Baseri, E. Konofagou, S. G. Carlier, "Challenges in Atherosclerotic Plaque Characterization with Intravascular Ultrasound (IVUS): From Data Collection to Classification," IEEE Trans. Info. Tech. Biomed., Vol.12, No.3, pp. 315-327, 2008.
    • (2008) IEEE Trans. Info. Tech. Biomed. , vol.12 , Issue.3 , pp. 315-327
    • Katouzian, A.1    Sathyanarayana, S.2    Baseri, B.3    Konofagou, E.4    Carlier, S.G.5
  • 15
    • 57049087603 scopus 로고    scopus 로고
    • Modeling of image-catheter motion for 3-D IVUS
    • M. Rosales, P. Radeva, O. R. Leor, D. Gil, "Modeling of image-catheter motion for 3-D IVUS," Medi. Imag. Anal., Vol.13, No.1, pp. 91-104, 2009.
    • (2009) Medi. Imag. Anal. , vol.13 , Issue.1 , pp. 91-104
    • Rosales, M.1    Radeva, P.2    Leor, O.R.3    Gil, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.