메뉴 건너뛰기




Volumn , Issue , 2010, Pages 1324-1327

Post-prandial plasma glucose prediction in type i diabetes based on Impulse Response Models

Author keywords

[No Author keywords available]

Indexed keywords

DATA SETS; FINITE IMPULSE RESPONSE MODEL; IMPULSE RESPONSE MODEL; PLASMA GLUCOSE; TYPE I DIABETES;

EID: 78650833215     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2010.5626386     Document Type: Conference Paper
Times cited : (13)

References (16)
  • 1
    • 77649337351 scopus 로고    scopus 로고
    • A review of closed-loop algorithms for glycemic control in the treatment of type 1 diabetes
    • J. E. Youssef, J. Castle, W. K. Ward, A review of closed-loop algorithms for glycemic control in the treatment of type 1 diabetes, Algorithms 2 (2009) 518-532.
    • (2009) Algorithms , vol.2 , pp. 518-532
    • Youssef, J.E.1    Castle, J.2    Ward, W.K.3
  • 3
    • 58649116460 scopus 로고    scopus 로고
    • Diabetes mellitus modeling and short-term prediction based on blood glucose measurement
    • F. Ståhl, R. Johansson, Diabetes mellitus modeling and short-term prediction based on blood glucose measurement, Mathematical Biosciences 217 (2009) 101-117.
    • (2009) Mathematical Biosciences , vol.217 , pp. 101-117
    • Ståhl, F.1    Johansson, R.2
  • 5
  • 8
    • 78650834759 scopus 로고    scopus 로고
    • 2010-06-03
    • DIAdvisor, www.diadvisor.eu, 2010-06-03.
  • 9
    • 78650843866 scopus 로고    scopus 로고
    • 2010-06-03
    • Abbott, www.abbottdiabetescare.com, 2010-06-03.
  • 10
    • 78650841263 scopus 로고    scopus 로고
    • 2010-06-03
    • HemoCue, www.hemocue.com, 2010-06-03.
  • 11
    • 78650811355 scopus 로고    scopus 로고
    • Matlab, 2010-06-03
    • Matlab, www.mathworks.com, 2010-06-03.
  • 13
    • 33845914748 scopus 로고    scopus 로고
    • A system model of oral glucose absorption: Validation on gold standard data
    • C. Dalla Man, M. Camilleri, C. Cobelli, A system model of oral glucose absorption: Validation on gold standard data, IEEE Trans. on Biomedical Engineering 53 (12) (2006) 2472-2478.
    • (2006) IEEE Trans. on Biomedical Engineering , vol.53 , Issue.12 , pp. 2472-2478
    • Dalla Man, C.1    Camilleri, M.2    Cobelli, C.3
  • 14
    • 0023205574 scopus 로고
    • Evaluating clinical accuracy of systems for self-monitoring of blood glucose
    • W. L. Clarke, D. Cox, L. A. Gonder-Frederick, W. Carter, S. L. Pohl, Evaluating clinical accuracy of systems for self-monitoring of blood glucose, Diabetes Care 10 (1987) 622-628.
    • (1987) Diabetes Care , vol.10 , pp. 622-628
    • Clarke, W.L.1    Cox, D.2    Gonder-Frederick, L.A.3    Carter, W.4    Pohl, S.L.5
  • 15
    • 0025958256 scopus 로고
    • The dawn phenomenon in type 1 (insulindependent) diabetes mellitus: Magnitude frequency variability and dependency on glucose counterregnlation and insulin sensitivity
    • G. Perriello, R. D. Feo, E. Torlone, C. Fanelli, E. Santeusanio, R. Brunetti, G. B. BoUi, The dawn phenomenon in type 1 (insulindependent) diabetes mellitus: magnitude, frequency, variability, and dependency on glucose counterregnlation and insulin sensitivity, Diabetologia 34 (1991) 21-28.
    • (1991) Diabetologia , vol.34 , pp. 21-28
    • Perriello, G.1    Feo, R.D.2    Torlone, E.3    Fanelli, C.4    Santeusanio, E.5    Brunetti, R.6    Boui, G.B.7
  • 16
    • 54749122334 scopus 로고    scopus 로고
    • Glucose prediction algorithms from continuous monitoring data: Assessment of accuracy via continuous glucose error-grid analysis
    • F. Zanderigo, G. Sparacino, B. Kovatchev, C. Cobelli, Glucose prediction algorithms from continuous monitoring data: Assessment of accuracy via continuous glucose error-grid analysis, J. Diabetes Science and Technology 1 (5) (2007) 645-651.
    • (2007) J. Diabetes Science and Technology , vol.1 , Issue.5 , pp. 645-651
    • Zanderigo, F.1    Sparacino, G.2    Kovatchev, B.3    Cobelli, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.