메뉴 건너뛰기




Volumn 1, Issue 5, 2007, Pages 645-651

Glucose prediction algorithms from continuous monitoring data: Assessment of accuracy via continuous glucose error-grid analysis

Author keywords

Auto regressive model; Glucose sensor; Hypoglycemia; Polynomial model; Time series

Indexed keywords


EID: 54749122334     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/193229680700100508     Document Type: Article
Times cited : (39)

References (7)
  • 1
    • 18144421498 scopus 로고    scopus 로고
    • Continuous glucose monitoring: Roadmap for 21st century diabetes therapy
    • May
    • Klonoff DC. Continuous glucose monitoring: roadmap for 21st century diabetes therapy. Diabetes Care. 2005 May; 28(5):1231-9.
    • (2005) Diabetes Care. , vol.28 , Issue.5 , pp. 1231-1239
    • Klonoff, D.C.1
  • 2
    • 34247372642 scopus 로고    scopus 로고
    • Glucose concentration can be predicted ahead in time from continuous glucose monitoring sensor time-series
    • May
    • Sparacino G, Zanderigo F, Corazza S, Maran A, Facchinetti A, Cobelli C. Glucose concentration can be predicted ahead in time from continuous glucose monitoring sensor time-series. IEEE Trans Biomed Eng. 2007 May; 54(5):931-7.
    • (2007) IEEE Trans Biomed Eng. , vol.54 , Issue.5 , pp. 931-937
    • Sparacino, G.1    Zanderigo, F.2    Corazza, S.3    Maran, A.4    Facchinetti, A.5    Cobelli, C.6
  • 3
    • 3342981187 scopus 로고    scopus 로고
    • Evaluating the accuracy of continuous glucose-monitoring sensors: Continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data
    • Aug.
    • Kovatchev BP, Gonder-Frederick LA, Cox DJ, Clarke WL. Evaluating the accuracy of continuous glucose-monitoring sensors: continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data. Diabetes Care. 2004 Aug; 27(8):1922-8.
    • (2004) Diabetes Care. , vol.27 , Issue.8 , pp. 1922-1928
    • Kovatchev, B.P.1    Gonder-Frederick, L.A.2    Cox, D.J.3    Clarke, W.L.4
  • 5
    • 0023205574 scopus 로고
    • Evaluating clinical accuracy of systems for self-monitoring of blood glucose
    • Sep-Oct
    • Clarke WL, Cox D, Gonder-Frederick LA, Carter W, Pohl SL. Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care. 1987 Sep-Oct; 10(5):622-8.
    • (1987) Diabetes Care. , vol.10 , Issue.5 , pp. 622-628
    • Clarke, W.L.1    Cox, D.2    Gonder-Frederick, L.A.3    Carter, W.4    Pohl, S.L.5
  • 7
    • 85039636295 scopus 로고    scopus 로고
    • Prediction of glucose concentration from CGM data through AR time-series models: Role of sampling frequency and other design variables [abstract]
    • Nov. Atlanta, GA
    • Facchinetti A, Sparacino G, Zanderigo F, Cobelli C. Prediction of glucose concentration from CGM data through AR time-series models: role of sampling frequency and other design variables [abstract]. Diabetes Technology Meeting; 2006 Nov; Atlanta, GA.
    • (2006) Diabetes Technology Meeting
    • Facchinetti, A.1    Sparacino, G.2    Zanderigo, F.3    Cobelli, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.