메뉴 건너뛰기




Volumn , Issue , 2010, Pages 6226-6229

Interleaved multichannel epimysial stimulation for eliciting smooth contraction of muscle with reduced fatigue

Author keywords

[No Author keywords available]

Indexed keywords

FORCE PROFILE; FORCE RESPONSE; FUNCTIONAL ELECTRICAL STIMULATION; HIGH FIDELITY; INVASIVENESS; LOW FREQUENCY; MULTI-CHANNEL; MULTIELECTRODE ARRAYS; SIMULTANEOUS STIMULATIONS; STIMULATION PATTERN; STIMULATION PROTOCOLS;

EID: 78650823015     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2010.5627717     Document Type: Conference Paper
Times cited : (16)

References (5)
  • 1
    • 0030831031 scopus 로고    scopus 로고
    • Functional electrical stimulation
    • D. N. Rushton, "Functional electrical stimulation," Physiol. Meas., vol. 18, pp. 241-275, 1997.
    • (1997) Physiol. Meas. , vol.18 , pp. 241-275
    • Rushton, D.N.1
  • 2
    • 23844471959 scopus 로고    scopus 로고
    • Functional electrical stimulation for neuromuscular applications
    • P. H. Peckham and J. S. Knutson, "Functional electrical stimulation for neuromuscular applications," Annu. Rev. Biomed. Eng., vol. 7, pp. 327-360, 2005.
    • (2005) Annu. Rev. Biomed. Eng. , vol.7 , pp. 327-360
    • Peckham, P.H.1    Knutson, J.S.2
  • 3
    • 77950996323 scopus 로고    scopus 로고
    • Implementation of integratable PDMS-based conformable microelectrode arrays using a multilayer wiring interconnect technology
    • Minneapolis, Minnesota
    • L. Guo and S. P. DeWeerth, "Implementation of Integratable PDMS-Based Conformable Microelectrode Arrays Using a Multilayer Wiring Interconnect Technology," in Conf. Proc. IEEE Eng. Med. Biol., Minneapolis, Minnesota, 2009.
    • (2009) Conf. Proc. IEEE Eng. Med. Biol.
    • Guo, L.1    Deweerth, S.P.2
  • 4
    • 2942677561 scopus 로고    scopus 로고
    • Interleaved, multisite electrical stimulation of cat sciatic nerve produces fatigue-resistant, ripple-free motor responses
    • D. McDonnall, et al., "Interleaved, multisite electrical stimulation of cat sciatic nerve produces fatigue-resistant, ripple-free motor responses," IEEE T. Neur. Sys. Reh., vol. 12, pp. 208-215, 2004.
    • (2004) IEEE T. Neur. Sys. Reh. , vol.12 , pp. 208-215
    • McDonnall, D.1
  • 5
    • 78650324379 scopus 로고    scopus 로고
    • A histochemical and physiological analysis of performance in the plantaris longus muscle of the frog (rana pipiens) and the toad (bufo valliceps)
    • C. D. Moore, "A Histochemical and Physiological Analysis of Performance in the Plantaris Longus Muscle of the Frog (Rana pipiens) and the Toad (Bufo valliceps)," Bios, vol. 68, pp. 234-242, 1997.
    • (1997) Bios , vol.68 , pp. 234-242
    • Moore, C.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.