메뉴 건너뛰기




Volumn , Issue , 2010, Pages 5815-5818

Prototype of a wearable system for remote fetal monitoring during pregnancy

Author keywords

[No Author keywords available]

Indexed keywords

ECG RECORDING; FETAL ECG; FETAL HEART RATE; TEXTILE ELECTRODES; WEARABLE SYSTEMS; WEARABLE UNIT; WELLBEING;

EID: 78650818059     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2010.5627470     Document Type: Conference Paper
Times cited : (32)

References (16)
  • 4
    • 0019139694 scopus 로고
    • The accuracy of abdominal ECG for fetal electronic monitoring
    • T. Solum, I. Ingemarsson, A. Nygren, "The accuracy of abdominal ECG for fetal electronic monitoring", J. Perinat. Med., vol. 8, pp. 142-149, 1980. (Pubitemid 11235549)
    • (1980) Journal of Perinatal Medicine , vol.8 , Issue.3 , pp. 142-149
    • Solum, T.1    Ingermarsson, I.2    Nygren, A.3
  • 6
    • 30444436204 scopus 로고    scopus 로고
    • Comparison of entropy based regularity estimators: Application to the Fetal Heart Rate signal for the identification of fetal distress
    • M. Ferrario, M.G. Signorini, G. Magenes, S. Cerutti, "Comparison of entropy based regularity estimators: application to the Fetal Heart Rate signal for the identification of fetal distress", IEEE Trans Biom Eng, vol. 53, no. 1, pp. 119-125, 2006.
    • (2006) IEEE Trans Biom Eng , vol.53 , Issue.1 , pp. 119-125
    • Ferrario, M.1    Signorini, M.G.2    Magenes, G.3    Cerutti, S.4
  • 7
    • 33947547486 scopus 로고    scopus 로고
    • Comparison between fetal heart rate standard parameters and complexity indexes for the identification of severe intrauterine growth restriction
    • M. Ferrario, M.G. Signorini, G. Magenes, "Comparison between fetal heart rate standard parameters and complexity indexes for the identification of severe intrauterine growth restriction.", Methods of Information in Medicine, vol. 46, no. 2, pp. 186-190, 2007.
    • (2007) Methods of Information in Medicine , vol.46 , Issue.2 , pp. 186-190
    • Ferrario, M.1    Signorini, M.G.2    Magenes, G.3
  • 8
    • 0344837758 scopus 로고    scopus 로고
    • Linear and nonlinear parameters for the analysis of fetal heart rate signal from cardiotocographic recordings
    • M. Ferrario, M.G. Signorini, G. Magenes, S. Cerutti, D. Arduini, "Linear and Nonlinear Parameters for the Analysis of Fetal Heart Rate Signal from Cardiotocographic Recordings", IEEE Trans Biom Eng, vol. 50, no. 3, pp. 347-357, 2003.
    • (2003) IEEE Trans Biom Eng , vol.50 , Issue.3 , pp. 347-357
    • Ferrario, M.1    Signorini, M.G.2    Magenes, G.3    Cerutti, S.4    Arduini, D.5
  • 10
    • 0019732797 scopus 로고
    • A new technique for the suppression of the MECG
    • P. B. W. J. Meijer, "A new technique for the suppression of the MECG", IEEE Trans. Biomed. Eng., vol. 28, pp. 248-353, 1981.
    • (1981) IEEE Trans. Biomed. Eng. , vol.28 , pp. 248-353
    • Meijer, P.B.W.J.1
  • 11
    • 0022861192 scopus 로고
    • Variability analysis of fetal heart rate signals as obtained from abdominal electrocardiographic recordings
    • S. Cerutti, G. Baselli, S. Civardi, E. Ferrazzi, A. M. Marconi, M. Pagani and G. Pardi, "Variability analysis of fetal heart rate signals as obtained from abdominal electrocardiographic recordings", J. Perinat. Med, vol. 14, pp. 445-452, 1981.
    • (1981) J. Perinat. Med , vol.14 , pp. 445-452
    • Cerutti, S.1    Baselli, G.2    Civardi, S.3    Ferrazzi, E.4    Marconi, A.M.5    Pagani, M.6    Pardi, G.7
  • 12
    • 0022885980 scopus 로고
    • An adaptive on-line method for the extraction of the complete fetal electrocardiogram from cutaneous multilead recordings
    • D. Callaerts, J. Vanderschoot, J. Vandewalle, W. Sansen, G. Vantrappen and J. Janssens, "An adaptive on-line method for the extraction of the complete fetal electrocardiogram from cutaneous multilead recordings", J. Perinat. Med.vol. 14, pp. 421-433, 1986.
    • (1986) J. Perinat. Med. , vol.14 , pp. 421-433
    • Callaerts, D.1    Vanderschoot, J.2    Vandewalle, J.3    Sansen, W.4    Vantrappen, G.5    Janssens, J.6
  • 13
    • 0034108045 scopus 로고    scopus 로고
    • Fetal electrocardiogram extraction by blind source subspace Separation
    • L. D. Lathauwer, B. D. Moor and J. Vanderwalle, "Fetal electrocardiogram extraction by blind source subspace Separation", IEEE Trans. Biomed. Eng. vol. 47, pp. 567-572, 2000.
    • (2000) IEEE Trans. Biomed. Eng. , vol.47 , pp. 567-572
    • Lathauwer, L.D.1    Moor, B.D.2    Vanderwalle, J.3
  • 15
    • 78650809530 scopus 로고    scopus 로고
    • Improving QRS detection in multi-channel electrocardiography by principal component analysis
    • S. M. M. Martens, R. J. Sluijter, S. G. Oei and J. W. M. Bergmans, "Improving QRS detection in multi-channel electrocardiography by principal component analysis", IFMBE Proc. EMBEC, no. 11, 2005.
    • (2005) IFMBE Proc. EMBEC , Issue.11
    • Martens, S.M.M.1    Sluijter, R.J.2    Oei, S.G.3    Bergmans, J.W.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.