메뉴 건너뛰기




Volumn 25, Issue 1, 2011, Pages 44-50

Biomechanical comparison of locking versus nonlocking volar and dorsal T-plates for fixation of dorsally comminuted distal radius fractures

Author keywords

biomechanical; distal radius fracture; dorsal comminution; dorsal plate; extra articular; volar plate

Indexed keywords

ARTICLE; BIOMECHANICS; COMMINUTED FRACTURE; COMPARATIVE STUDY; DORSAL T PLATE; HUMAN; ORTHOPEDIC EQUIPMENT; OSTEOTOMY; PLATE FIXATION; PRIORITY JOURNAL; RADIUS FRACTURE; RANDOMIZED CONTROLLED TRIAL; RIGIDITY; SURGICAL TECHNIQUE; VOLAR PLATE;

EID: 78650799869     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/BOT.0b013e3181d7a3a6     Document Type: Article
Times cited : (22)

References (36)
  • 1
    • 77954668744 scopus 로고    scopus 로고
    • Distal radius fractures
    • In: Manske PR, ed., Rosemont, IL: American Academy of Orthopaedic Surgeons
    • Sanders WE. Distal radius fractures. In: Manske PR, ed. Hand Surgery Update. Rosemont, IL: American Academy of Orthopaedic Surgeons; 1996:117-123.
    • (1996) Hand Surgery Update , pp. 117-123
    • Sanders, W.E.1
  • 2
    • 33750802999 scopus 로고    scopus 로고
    • Internal fixation of dorsally displaced fractures of the distal part of the radius
    • Willis AA, Kutsumi K, Zobitz ME, et al. Internal fixation of dorsally displaced fractures of the distal part of the radius. J Bone Joint Surg Am. 2006;88:2411-2417.
    • (2006) J Bone Joint Surg Am. , vol.88 , pp. 2411-2417
    • Willis, A.A.1    Kutsumi, K.2    Zobitz, M.E.3
  • 3
    • 22544486562 scopus 로고    scopus 로고
    • Locking versus nonlocking T-plates for dorsal and volar fixation of dorsally comminuted distal radius fractures: A biomechanical study
    • Trease C, McIff T, Toby EB. Locking versus nonlocking T-plates for dorsal and volar fixation of dorsally comminuted distal radius fractures: A biomechanical study. J Hand Surg [Am]. 2005;30:756-763.
    • (2005) J Hand Surg [Am]. , vol.30 , pp. 756-763
    • Trease, C.1    McIff, T.2    Toby, E.B.3
  • 4
    • 0032467256 scopus 로고    scopus 로고
    • Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: A multicenter study of 73 fractures
    • Carter PR, Frederick HA, Laseter GF. Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: A multicenter study of 73 fractures. J Hand Surg [Am]. 1998;23:300-307.
    • (1998) J Hand Surg [Am]. , vol.23 , pp. 300-307
    • Carter, P.R.1    Frederick, H.A.2    Laseter, G.F.3
  • 5
    • 0036241905 scopus 로고    scopus 로고
    • Palmar plating for dorsally displaced fractures of the distal radius
    • Kamano M, Honda Y, Kazuki K, et al. Palmar plating for dorsally displaced fractures of the distal radius. Clin Orthop Relat Res. 2002;397: 403-408.
    • (2002) Clin Orthop Relat Res. , vol.397 , pp. 403-408
    • Kamano, M.1    Honda, Y.2    Kazuki, K.3
  • 6
    • 0030928604 scopus 로고    scopus 로고
    • Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures
    • Ring D, Jupiter JB, Brennwald J, et al. Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures. J Hand Surg [Am]. 1997;22:777-784.
    • (1997) J Hand Surg [Am]. , vol.22 , pp. 777-784
    • Ring, D.1    Jupiter, J.B.2    Brennwald, J.3
  • 7
    • 0032460038 scopus 로고    scopus 로고
    • Complications of the AO/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: A brief report
    • Kambouroglou GK, Axelrod TS. Complications of the AO/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: A brief report. J Hand Surg [Am]. 1998;23:737-741.
    • (1998) J Hand Surg [Am]. , vol.23 , pp. 737-741
    • Kambouroglou, G.K.1    Axelrod, T.S.2
  • 8
    • 85046516875 scopus 로고    scopus 로고
    • Complications in internal fixation of the distal radius
    • Lucas GL, Fejfar ST. Complications in internal fixation of the distal radius. J Hand Surg [Am]. 1998;23:1117.
    • (1998) J Hand Surg [Am]. , vol.23 , pp. 1117
    • Lucas, G.L.1    Fejfar, S.T.2
  • 9
    • 0036130725 scopus 로고    scopus 로고
    • Volar fixation for dorsally displaced fractures of the distal radius: A preliminary report
    • Orbay JL, Fernandez DL. Volar fixation for dorsally displaced fractures of the distal radius: A preliminary report. J Hand Surg [Am]. 2002;27: 205-215.
    • (2002) J Hand Surg [Am]. , vol.27 , pp. 205-215
    • Orbay, J.L.1    Fernandez, D.L.2
  • 10
    • 18744407595 scopus 로고    scopus 로고
    • Volar fixed-angle plating of the distal radius
    • Smith DW, Henry MH. Volar fixed-angle plating of the distal radius. J Am Acad Orthop Surg. 2005;13:28-36.
    • (2005) J Am Acad Orthop Surg. , vol.13 , pp. 28-36
    • Smith, D.W.1    Henry, M.H.2
  • 11
    • 0025364276 scopus 로고
    • Open reduction and internal fixation of comminuted, intraarticular fractures of the distal radius
    • Axelrod TS, McMurtry RY. Open reduction and internal fixation of comminuted, intraarticular fractures of the distal radius. J Hand Surg [Am]. 1990;15:1-11.
    • (1990) J Hand Surg [Am]. , vol.15 , pp. 1-11
    • Axelrod, T.S.1    McMurtry, R.Y.2
  • 12
    • 0036068485 scopus 로고    scopus 로고
    • Failure of a retinacular flap to prevent dorsal wrist pain after titanium Pi plate fixation of distal radius fractures
    • Chiang PP, Roach S, Baratz ME. Failure of a retinacular flap to prevent dorsal wrist pain after titanium Pi plate fixation of distal radius fractures. J Hand Surg [Am]. 2002;27:724-728.
    • (2002) J Hand Surg [Am]. , vol.27 , pp. 724-728
    • Chiang, P.P.1    Roach, S.2    Baratz, M.E.3
  • 13
    • 0034302091 scopus 로고    scopus 로고
    • Extensor tendon rupture secondary to the AO/ASIF titanium distal radius plate without associated plate failure: A case report
    • Lowry KJ, Gainor BJ, Hoskins JS. Extensor tendon rupture secondary to the AO/ASIF titanium distal radius plate without associated plate failure: A case report. Am J Orthop. 2000;29:789-791.
    • (2000) Am J Orthop. , vol.29 , pp. 789-791
    • Lowry, K.J.1    Gainor, B.J.2    Hoskins, J.S.3
  • 14
    • 16244400503 scopus 로고    scopus 로고
    • A biomechanical comparison of a dorsal 3.5mm T-plate and a volar fixed-angle plate in a model of dorsally unstable distal radius fractures
    • Liporace FA, Gupta S, Jeong GK, et al. A biomechanical comparison of a dorsal 3.5mm T-plate and a volar fixed-angle plate in a model of dorsally unstable distal radius fractures. J Orthop Trauma. 2005;19:187-191.
    • (2005) J Orthop Trauma. , vol.19 , pp. 187-191
    • Liporace, F.A.1    Gupta, S.2    Jeong, G.K.3
  • 15
    • 0028849835 scopus 로고
    • Design and biomechanics of a plate for the distal radius
    • Gesensway D, Putman MD, Mente PL, et al. Design and biomechanics of a plate for the distal radius. J Hand Surg [Am]. 1995;20:1021-1027.
    • (1995) J Hand Surg [Am]. , vol.20 , pp. 1021-1027
    • Gesensway, D.1    Putman, M.D.2    Mente, P.L.3
  • 16
    • 0037244095 scopus 로고    scopus 로고
    • Comparison of differential distal radius dorsal and volar fracture fixation plates: A biomechanical study
    • Osada D, Viegas SF, Shah MA, et al. Comparison of differential distal radius dorsal and volar fracture fixation plates: A biomechanical study. J Hand Surg [Am]. 2003;28:94-104.
    • (2003) J Hand Surg [Am]. , vol.28 , pp. 94-104
    • Osada, D.1    Viegas, S.F.2    Shah, M.A.3
  • 17
    • 0033976014 scopus 로고    scopus 로고
    • Comparison of three different plating techniques for the dorsum of the distal radius: A biomechanical study
    • Peine R, Rikli DA, Hoffman R, et al. Comparison of three different plating techniques for the dorsum of the distal radius: A biomechanical study. J Hand Surg [Am]. 2000;25:29-33.
    • (2000) J Hand Surg [Am]. , vol.25 , pp. 29-33
    • Peine, R.1    Rikli, D.A.2    Hoffman, R.3
  • 18
    • 33748746234 scopus 로고    scopus 로고
    • A biomechanical comparison of two volar locked plates in a dorsally unstable distal radius fracture model
    • Liporace FA, Kubiak EN, Jeong CK, et al. A biomechanical comparison of two volar locked plates in a dorsally unstable distal radius fracture model. J Trauma. 2006;61:668-672.
    • (2006) J Trauma. , vol.61 , pp. 668-672
    • Liporace, F.A.1    Kubiak, E.N.2    Jeong, C.K.3
  • 19
    • 0038627493 scopus 로고    scopus 로고
    • Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate - A biomechanical study in a cadaveric model
    • Leung F, Zhu L, Ho H, et al. Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate-a biomechanical study in a cadaveric model. J Hand Surg [Br]. 2003;28:263-266.
    • (2003) J Hand Surg [Br]. , vol.28 , pp. 263-266
    • Leung, F.1    Zhu, L.2    Ho, H.3
  • 20
    • 0032459843 scopus 로고    scopus 로고
    • Augmented external fixation of distal radius fractures: A biomechanical analysis
    • Wolfe SW, Swigart CR, Grauer J, et al. Augmented external fixation of distal radius fractures: A biomechanical analysis. J Hand Surg [Am]. 1998; 23:127-134.
    • (1998) J Hand Surg [Am]. , vol.23 , pp. 127-134
    • Wolfe, S.W.1    Swigart, C.R.2    Grauer, J.3
  • 21
    • 0023405624 scopus 로고
    • The effect of scapholunate ligament section on scapholunate motion
    • Ruby LK, An KN, Linscheid RL, et al. The effect of scapholunate ligament section on scapholunate motion. J Hand Surg [Am]. 1987;12:767-771.
    • (1987) J Hand Surg [Am]. , vol.12 , pp. 767-771
    • Ruby, L.K.1    An, K.N.2    Linscheid, R.L.3
  • 22
    • 0023257432 scopus 로고
    • A biomechanical study of distal radial fractures
    • Short WH, Palmer AK, Werner FW, et al. A biomechanical study of distal radial fractures. J Hand Surg [Am]. 1987;12:529-534.
    • (1987) J Hand Surg [Am]. , vol.12 , pp. 529-534
    • Short, W.H.1    Palmer, A.K.2    Werner, F.W.3
  • 23
    • 0021152944 scopus 로고
    • Biomechanics of the distal radioulnar joint
    • Palmer AK, Werner FW. Biomechanics of the distal radioulnar joint. Clin Orthop Relat Res. 1984;187:26-35.
    • (1984) Clin Orthop Relat Res. , vol.187 , pp. 26-35
    • Palmer, A.K.1    Werner, F.W.2
  • 24
    • 0023127661 scopus 로고
    • Forearm force transmission after surgical treatment of distal radioulnar joint disorders
    • Trumble TE, Glisson RR, Seaber AV, et al. Forearm force transmission after surgical treatment of distal radioulnar joint disorders. J Hand Surg [Am]. 1987;12:196-202.
    • (1987) J Hand Surg [Am]. , vol.12 , pp. 196-202
    • Trumble, T.E.1    Glisson, R.R.2    Seaber, A.V.3
  • 25
    • 0026605428 scopus 로고
    • Force distribution across wrist joint: Application of pressure-sensitive conductive rubber
    • Hara T, Horii E, An KN, et al. Force distribution across wrist joint: Application of pressure-sensitive conductive rubber. J Hand Surg [Am]. 1992;17:339-347.
    • (1992) J Hand Surg [Am]. , vol.17 , pp. 339-347
    • Hara, T.1    Horii, E.2    An, K.N.3
  • 26
    • 0032836522 scopus 로고    scopus 로고
    • Supplemental pinning improves stability of external fixation in distal radius fractures during simulated finger and forearm motion
    • Dunning CE, Lindsay CS, Bicknell RT, et al. Supplemental pinning improves stability of external fixation in distal radius fractures during simulated finger and forearm motion. J Hand Surg [Am]. 1999;24:992-1000.
    • (1999) J Hand Surg [Am]. , vol.24 , pp. 992-1000
    • Dunning, C.E.1    Lindsay, C.S.2    Bicknell, R.T.3
  • 27
    • 0032910060 scopus 로고    scopus 로고
    • Load displacement behavior in a distal radius fracture model
    • Wolfe SW, Lorenze MD, Austin G, et al. Load displacement behavior in a distal radius fracture model. J Bone Joint Surg Am. 1999;81:53-59.
    • (1999) J Bone Joint Surg Am. , vol.81 , pp. 53-59
    • Wolfe, S.W.1    Lorenze, M.D.2    Austin, G.3
  • 28
    • 0019569659 scopus 로고
    • Relative tension and potential excursion of muscles in the forearm and hand
    • Brand PW, Beach RB, Thompson DE. Relative tension and potential excursion of muscles in the forearm and hand. J Hand Surg [Am]. 1981;6: 209-219.
    • (1981) J Hand Surg [Am]. , vol.6 , pp. 209-219
    • Brand, P.W.1    Beach, R.B.2    Thompson, D.E.3
  • 29
  • 30
    • 0034193846 scopus 로고    scopus 로고
    • Distal radial metaphyseal forces in the extrinsic grip model: Implications for postfracture rehabilitation
    • Putnam MD, Meyer NJ, Nelson EW, et al. Distal radial metaphyseal forces in the extrinsic grip model: Implications for postfracture rehabilitation. J Hand Surg [Am]. 2000;25:469-475.
    • (2000) J Hand Surg [Am]. , vol.25 , pp. 469-475
    • Putnam, M.D.1    Meyer, N.J.2    Nelson, E.W.3
  • 31
    • 0032460007 scopus 로고    scopus 로고
    • Load relaxation and forces with activity in Hoffman external fixators: A clinical study in patients with Colles' fractures
    • Winemaker MJ, Chinchalkar S, Richards RS, et al. Load relaxation and forces with activity in Hoffman external fixators: A clinical study in patients with Colles' fractures. J Hand Surg [Am]. 1998;23: 926-932.
    • (1998) J Hand Surg [Am]. , vol.23 , pp. 926-932
    • Winemaker, M.J.1    Chinchalkar, S.2    Richards, R.S.3
  • 32
    • 15244355410 scopus 로고    scopus 로고
    • Functional outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixation
    • Wright TW, Horodyski M, Smith DW. Functional outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixation. J Hand Surg [Am]. 2005;30:289-299.
    • (2005) J Hand Surg [Am]. , vol.30 , pp. 289-299
    • Wright, T.W.1    Horodyski, M.2    Smith, D.W.3
  • 33
    • 0028885138 scopus 로고
    • The biomechanics of the PC-Fix internal fixator
    • Tepic S, Perren SM. The biomechanics of the PC-Fix internal fixator. Injury. 1995;26(Suppl 2):B5-B10.
    • (1995) Injury. , vol.26 , Issue.SUPPL. 2
    • Tepic, S.1    Perren, S.M.2
  • 35
    • 10644243673 scopus 로고    scopus 로고
    • An osteosynthesis plate based on the dynamic compression plate and the point contact fixator
    • Locking compression plate (LCP)
    • Frigg R. Locking compression plate (LCP). An osteosynthesis plate based on the dynamic compression plate and the point contact fixator. Injury. 2001;32(Suppl 2):B63-B66.
    • (2001) Injury. , vol.32 , Issue.SUPPL. 2
    • Frigg, R.1
  • 36
    • 58149380678 scopus 로고    scopus 로고
    • Does a volar locking plate provide equivalent stability as a dorsal nonlocking plate in a dorsally comminuted distal radius fracture?
    • Kandemir U, Matityahu A, Desai R, et al. Does a volar locking plate provide equivalent stability as a dorsal nonlocking plate in a dorsally comminuted distal radius fracture? J Orthop Trauma. 2008;22: 605-610.
    • (2008) J Orthop Trauma. , vol.22 , pp. 605-610
    • Kandemir, U.1    Matityahu, A.2    Desai, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.