메뉴 건너뛰기




Volumn 14, Issue 1, 2011, Pages 66-68

Suitability and calibration of a rebound tonometer to measure IOP in rabbit and pig eyes

Author keywords

Glaucoma; IOP; Linear function; Pig; Rabbit; Rebound tonometry

Indexed keywords

ANIMAL; ARTICLE; CALIBRATION; INSTRUMENTATION; INTRAOCULAR PRESSURE; OCULOPLETHYSMOGRAPHY; PHYSIOLOGY; RABBIT; STANDARD; SWINE;

EID: 78650784329     PISSN: 14635216     EISSN: 14635224     Source Type: Journal    
DOI: 10.1111/j.1463-5224.2010.00794.x     Document Type: Article
Times cited : (21)

References (9)
  • 3
    • 0035099812 scopus 로고    scopus 로고
    • A comparison of biomechanical properties between human and porcine cornea
    • Zeng Y, Yang J, Huang K et al. A comparison of biomechanical properties between human and porcine cornea. Journal of Biomechanics 2001; 34: 533-537.
    • (2001) Journal of Biomechanics , vol.34 , pp. 533-537
    • Zeng, Y.1    Yang, J.2    Huang, K.3
  • 4
    • 0033863370 scopus 로고    scopus 로고
    • A resonator sensor for measurement of intraocular pressure-evaluation in an in vitro pig-eye model
    • Eklund A, Bäcklund T, Lindahl OA. A resonator sensor for measurement of intraocular pressure-evaluation in an in vitro pig-eye model. Physiological Measurement 2000; 21: 355-367.
    • (2000) Physiological Measurement , vol.21 , pp. 355-367
    • Eklund, A.1    Bäcklund, T.2    Lindahl, O.A.3
  • 5
    • 43649095145 scopus 로고    scopus 로고
    • Assessment of true intraocular pressure: the gap between theory and practical data
    • Chihara E. Assessment of true intraocular pressure: the gap between theory and practical data. Survey of Ophthalmology 2008; 53: 203-218.
    • (2008) Survey of Ophthalmology , vol.53 , pp. 203-218
    • Chihara, E.1
  • 7
    • 34247543848 scopus 로고    scopus 로고
    • Evaluierung der Reboundtonometrie (ICare) im Vergleich zum Tonopen XL und dem Goldmann-Applanationstonometer [A comparison of rebound tonometry (ICare) with TonoPenXL and Goldmann applanation tonometry]
    • Schreiber W, Vorwerk CK, Langenbucher A et al. Evaluierung der Reboundtonometrie (ICare) im Vergleich zum Tonopen XL und dem Goldmann-Applanationstonometer [A comparison of rebound tonometry (ICare) with TonoPenXL and Goldmann applanation tonometry]. Ophthalmologe 2007; 104: 299-304.
    • (2007) Ophthalmologe , vol.104 , pp. 299-304
    • Schreiber, W.1    Vorwerk, C.K.2    Langenbucher, A.3
  • 8
    • 33747010633 scopus 로고    scopus 로고
    • Comparison of Goldmann applanation and applanation resonance tonometry in a biomicroscope-based in vitro porcine eye model
    • Hallberg P, Santala K, Linden C et al. Comparison of Goldmann applanation and applanation resonance tonometry in a biomicroscope-based in vitro porcine eye model. Journal of Medical Engineering & Technology 2006; 30: 345-352.
    • (2006) Journal of Medical Engineering & Technology , vol.30 , pp. 345-352
    • Hallberg, P.1    Santala, K.2    Linden, C.3
  • 9
    • 33644924878 scopus 로고    scopus 로고
    • Comparison of the rebound tonometer (ICare) to the applanation tonometer (Tonopen XL) in normotensive dogs
    • Leiva M, Naranjo C, Peña MT. Comparison of the rebound tonometer (ICare) to the applanation tonometer (Tonopen XL) in normotensive dogs. Veterinary Ophthalmology 2006; 9: 17-21.
    • (2006) Veterinary Ophthalmology , vol.9 , pp. 17-21
    • Leiva, M.1    Naranjo, C.2    Peña, M.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.