메뉴 건너뛰기




Volumn 9, Issue 1, 2006, Pages 17-21

Comparison of the rebound tonometer (ICare®) to the applanation tonometer (Tonopen XL®) in normotensive dogs

Author keywords

Dog; Dynamic; Impact; Intraocular pressure; Rebound; Tonometer

Indexed keywords

ANIMAL; ANIMAL DISEASE; ARTICLE; CLINICAL TRIAL; COMPARATIVE STUDY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DOG; DOG DISEASE; FEMALE; INSTRUMENTATION; INTRAOCULAR PRESSURE; MALE; METHODOLOGY; OCULOPLETHYSMOGRAPHY; PHYSIOLOGY; PROSPECTIVE STUDY; RANDOMIZED CONTROLLED TRIAL; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; STANDARD;

EID: 33644924878     PISSN: 14635216     EISSN: 14635224     Source Type: Journal    
DOI: 10.1111/j.1463-5224.2005.00429.x     Document Type: Article
Times cited : (79)

References (29)
  • 1
    • 0003093827 scopus 로고    scopus 로고
    • Ophthalmic examination and diagnostic procedures
    • In. Lippincott, Williams & Wilkins Philadelphia 3rd edn. (ed
    • Strubbe T Gelatt K Ophthalmic examination and diagnostic procedures In Veterinary Ophthalmology 3rd edn. (ed Gelatt KN Lippincott, Williams & Wilkins Philadelphia 1999 427 466
    • (1999) Veterinary Ophthalmology*Gelatt K.N. , pp. 427-466
    • Strubbe, T.1    Gelatt, K.2
  • 2
    • 0001063063 scopus 로고
    • Contribution to the theory and practice of tonometry
    • Friedenwald JS Contribution to the theory and practice of tonometry American Journal of Ophthalmology 1937 20 985 1024
    • (1937) American Journal of Ophthalmology , vol.20 , pp. 985-1024
    • Friedenwald, J.S.1
  • 4
    • 0030318702 scopus 로고    scopus 로고
    • A new electromechanical method for measuring intraocular pressure
    • Kontiola A A new electromechanical method for measuring intraocular pressure Documenta Ophthalmologica 1997 93 265 276
    • (1997) Documenta Ophthalmologica , vol.93 , pp. 265-276
    • Kontiola, A.1
  • 9
    • 0034115306 scopus 로고    scopus 로고
    • A new induction-based impact method for measuring intraocular pressure
    • Kontiola AI A new induction-based impact method for measuring intraocular pressure Acta Ophthalmologica Scandinavica 2000 78 142 145
    • (2000) Acta Ophthalmologica Scandinavica , vol.78 , pp. 142-145
    • Kontiola, A.I.1
  • 10
    • 0035704347 scopus 로고    scopus 로고
    • The induction/impact tonometer: A new instrument to measure intraocular pressure in the rat
    • Kontiola AI Goldblum D Mittag T et al. The induction/impact tonometer: a new instrument to measure intraocular pressure in the rat Experimental Eye Research 2001 73 781 785
    • (2001) Experimental Eye Research , vol.73 , pp. 781-785
    • Kontiola, A.I.1    Goldblum, D.2    Mittag, T.3
  • 13
    • 0036946949 scopus 로고    scopus 로고
    • Non-invasive determination of intraocular pressure in the rat eye. Comparison of an electronic tonometer (Tonopen), and a rebound (impact probe) tonometer
    • Goldblum D Kontiola A Mittag T et al. Non-invasive determination of intraocular pressure in the rat eye. Comparison of an electronic tonometer (Tonopen), and a rebound (impact probe) tonometer Graefes Archive for Clinical and Experimental Ophthalmology 2002 240 942 946
    • (2002) Graefes Archive for Clinical and Experimental Ophthalmology , vol.240 , pp. 942-946
    • Goldblum, D.1    Kontiola, A.2    Mittag, T.3
  • 19
    • 0028097072 scopus 로고
    • Influence of topical anesthesia on tonometric values of intraocular pressure
    • Badouin C Gastaud P Influence of topical anesthesia on tonometric values of intraocular pressure Ophthalmologica 1994 208 309 313
    • (1994) Ophthalmologica , vol.208 , pp. 309-313
    • Badouin, C.1    Gastaud, P.2
  • 20
    • 1142299596 scopus 로고    scopus 로고
    • Measuring intraocular pressure with the Pulsair 300 and Rebound tonometers in elderly patients without anesthetic
    • Kontiola A Puska P Measuring intraocular pressure with the Pulsair 300 and Rebound tonometers in elderly patients without anesthetic Graefes Archive for Clinical and Experimental Ophthalmology 2004 242 3 7
    • (2004) Graefes Archive for Clinical and Experimental Ophthalmology , vol.242 , pp. 3-7
    • Kontiola, A.1    Puska, P.2
  • 23
    • 0040498092 scopus 로고    scopus 로고
    • Distribution of intraocular pressure in dogs
    • Gelatt K Mackay EO Distribution of intraocular pressure in dogs Veterinary Ophthalmology 1998 1 2-3 109 114
    • (1998) Veterinary Ophthalmology , vol.1 , Issue.2-3 , pp. 109-114
    • Gelatt, K.1    MacKay, E.O.2
  • 25
    • 0001622562 scopus 로고
    • Diurnal variations in intraocular pressure in normotensive and glaucomatous Beagles
    • Gelatt KN Gum GG Barrie KP et al. Diurnal variations in intraocular pressure in normotensive and glaucomatous Beagles Glaucoma 1981 3 21 24
    • (1981) Glaucoma , vol.3 , pp. 21-24
    • Gelatt, K.N.1    Gum, G.G.2    Barrie, K.P.3
  • 26
    • 0015011454 scopus 로고
    • Intraocular pressures in the beagle dog
    • Heywood R Intraocular pressures in the beagle dog Journal of Small Animal Practice 1971 12 119 121
    • (1971) Journal of Small Animal Practice , vol.12 , pp. 119-121
    • Heywood, R.1
  • 28
    • 0033777586 scopus 로고    scopus 로고
    • Accurate intraocular pressure measurement: The myth of modern ophthalmology?
    • Shah S Accurate intraocular pressure measurement: the myth of modern ophthalmology? Ophthalmology 2000 107 1805 1807
    • (2000) Ophthalmology , vol.107 , pp. 1805-1807
    • Shah, S.1
  • 29
    • 0031848594 scopus 로고    scopus 로고
    • Applanation tonometry and correction according to corneal thickness
    • Stodtmeister R Applanation tonometry and correction according to corneal thickness Acta Ophthalmologica Scandinavica 1998 76 319 324
    • (1998) Acta Ophthalmologica Scandinavica , vol.76 , pp. 319-324
    • Stodtmeister, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.