메뉴 건너뛰기




Volumn 18, Issue 7, 2008, Pages 1350-1355

Computer-aided detection of pulmonary embolism: Influence on radiologists' detection performance with respect to vessel segments

Author keywords

Computer tomography angiogram (CTA); Computer aided detection (CAD); Multidetector row computed tomography (MDCT); Pulmonary embolism (PE)

Indexed keywords

ADULT; ARTICLE; BLOOD VESSEL PARAMETERS; CLINICAL ARTICLE; COMPUTER ASSISTED RADIOGRAPHY; COMPUTER PROGRAM; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; FEMALE; HUMAN; LUNG BLOOD VESSEL; LUNG EMBOLISM; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SENSITIVITY ANALYSIS; SENSITIVITY AND SPECIFICITY; THORAX RADIOGRAPHY; THROMBOSIS;

EID: 45849092871     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-008-0889-x     Document Type: Article
Times cited : (56)

References (23)
  • 1
    • 22844446155 scopus 로고    scopus 로고
    • CT imaging in acute pulmonary embolism: Diagnostic strategies
    • Wildberger JE, Mahnken AH, Das M et al (2005) CT imaging in acute pulmonary embolism: Diagnostic strategies. Eur Radiol 15:919-929
    • (2005) Eur Radiol , vol.15 , pp. 919-929
    • Wildberger, J.E.1    Mahnken, A.H.2    Das, M.3
  • 2
    • 33947694585 scopus 로고    scopus 로고
    • Diagnostic pathways in acute pulmonary embolism: Recommendations of the PIOPED II investigators
    • Stein PD, Woodard PK, Weg JG et al (2006) Diagnostic pathways in acute pulmonary embolism: Recommendations of the PIOPED II investigators. Am J Med 119:1048-1055
    • (2006) Am J Med , vol.119 , pp. 1048-1055
    • Stein, P.D.1    Woodard, P.K.2    Weg, J.G.3
  • 3
    • 33845644987 scopus 로고    scopus 로고
    • Diagnostic pathways in acute pulmonary embolism: Recommendations of the PIOPED II Investigators
    • Stein PD, Woodard PK, Weg JG et al (2007) Diagnostic pathways in acute pulmonary embolism: Recommendations of the PIOPED II Investigators. Radiology 242:15-21
    • (2007) Radiology , vol.242 , pp. 15-21
    • Stein, P.D.1    Woodard, P.K.2    Weg, J.G.3
  • 4
    • 33744503127 scopus 로고    scopus 로고
    • Multidetector computed tomography for acute pulmonary embolism
    • Stein PD, Fowler SE, Goodman LR et al (2006) Multidetector computed tomography for acute pulmonary embolism. N Engl J Med 354:2317-2327
    • (2006) N Engl J Med , vol.354 , pp. 2317-2327
    • Stein, P.D.1    Fowler, S.E.2    Goodman, L.R.3
  • 5
    • 0038471175 scopus 로고    scopus 로고
    • British Thoracic Society guidelines for the management of suspected acute pulmonary embolism
    • British Thoracic Society Standards of Care Committee Pulmonary Embolism Guideline Development Group
    • British Thoracic Society Standards of Care Committee Pulmonary Embolism Guideline Development Group (2003) British Thoracic Society guidelines for the management of suspected acute pulmonary embolism. Thorax 58:470-483
    • (2003) Thorax , vol.58 , pp. 470-483
  • 6
    • 30444431617 scopus 로고    scopus 로고
    • Effectiveness of managing suspected pulmonary embolism using an algorithm combining clinical probability, D-dimer testing, and computed tomography
    • van Belle A, Buller HR, Huisman MV et al (2006) Effectiveness of managing suspected pulmonary embolism using an algorithm combining clinical probability, D-dimer testing, and computed tomography. Jama 295:172-179
    • (2006) Jama , vol.295 , pp. 172-179
    • van Belle, A.1    Buller, H.R.2    Huisman, M.V.3
  • 7
    • 0030711577 scopus 로고    scopus 로고
    • Pulmonary embolism: Prospective comparison of spiral CT with ventilation-perfusion scintigraphy
    • Mayo JR, Remy-Jardin M, Muller NL et al (1997) Pulmonary embolism: prospective comparison of spiral CT with ventilation-perfusion scintigraphy. Radiology 205:447-452
    • (1997) Radiology , vol.205 , pp. 447-452
    • Mayo, J.R.1    Remy-Jardin, M.2    Muller, N.L.3
  • 8
    • 0029026454 scopus 로고
    • Detection of pulmonary embolism in patients with unresolved clinical and scintigraphic diagnosis: Helical CT versus angiography
    • Goodman LR, Curtin JJ, Mewissen MW et al (1995) Detection of pulmonary embolism in patients with unresolved clinical and scintigraphic diagnosis: Helical CT versus angiography. AJR Am J Roentgenol 6:1369-1374
    • (1995) AJR Am J Roentgenol , vol.6 , pp. 1369-1374
    • Goodman, L.R.1    Curtin, J.J.2    Mewissen, M.W.3
  • 9
    • 0031878546 scopus 로고    scopus 로고
    • Pulmonary embolism: Diagnosis with spiral CT and ventilation-perfusion scanning-correlation with pulmonary angiographic results or clinical outcome
    • Garg K, Welsh CH, Feyerabend AJ et al (1998) Pulmonary embolism: diagnosis with spiral CT and ventilation-perfusion scanning-correlation with pulmonary angiographic results or clinical outcome. Radiology 208:201-208
    • (1998) Radiology , vol.208 , pp. 201-208
    • Garg, K.1    Welsh, C.H.2    Feyerabend, A.J.3
  • 10
    • 0030039489 scopus 로고    scopus 로고
    • Role of spiral volumetric computed tomographic scanning in the assessment of patients with clinical suspicion of pulmonary embolism and an abnormal ventilation/perfusion lung scan
    • van Rossum AB, Treurniet FE, Kieft GJ et al (1996) Role of spiral volumetric computed tomographic scanning in the assessment of patients with clinical suspicion of pulmonary embolism and an abnormal ventilation/perfusion lung scan. Thorax 51:23-28
    • (1996) Thorax , vol.51 , pp. 23-28
    • van Rossum, A.B.1    Treurniet, F.E.2    Kieft, G.J.3
  • 11
    • 0029831577 scopus 로고    scopus 로고
    • Diagnosis of pulmonary embolism with spiral CT: Comparison with pulmonary angiography and scintigraphy
    • Remy-Jardin M, Remy J, Deschildre F et al (1996) Diagnosis of pulmonary embolism with spiral CT: Comparison with pulmonary angiography and scintigraphy. Radiology 200:699-706
    • (1996) Radiology , vol.200 , pp. 699-706
    • Remy-Jardin, M.1    Remy, J.2    Deschildre, F.3
  • 12
    • 0033752851 scopus 로고    scopus 로고
    • Pulmonary embolism detection: Prospective evaluation of dual-section helical CT versus selective pulmonary arteriography in 157 patients
    • Qanadli SD, Hajjam ME, Mesurolle B et al (2000) Pulmonary embolism detection: Prospective evaluation of dual-section helical CT versus selective pulmonary arteriography in 157 patients. Radiology 217:447-455
    • (2000) Radiology , vol.217 , pp. 447-455
    • Qanadli, S.D.1    Hajjam, M.E.2    Mesurolle, B.3
  • 13
    • 0036153994 scopus 로고    scopus 로고
    • Subsegmental pulmonary emboli: Improved detection with thin-collimation multi-detector row spiral CT
    • Schoepf UJ, Holzknecht N, Helmberger TK et al (2002) Subsegmental pulmonary emboli: Improved detection with thin-collimation multi-detector row spiral CT. Radiology 222:483-490
    • (2002) Radiology , vol.222 , pp. 483-490
    • Schoepf, U.J.1    Holzknecht, N.2    Helmberger, T.K.3
  • 14
    • 0037591923 scopus 로고    scopus 로고
    • Diagnosis of pulmonary embolism with spiral CT as a second procedure following scintigraphy
    • van Strijen MJ, de Monyé W, Kieft GJ et al (2003) Diagnosis of pulmonary embolism with spiral CT as a second procedure following scintigraphy. Eur Radiol 13:1501-1507
    • (2003) Eur Radiol , vol.13 , pp. 1501-1507
    • van Strijen, M.J.1    de Monyé, W.2    Kieft, G.J.3
  • 15
    • 33947182969 scopus 로고    scopus 로고
    • Multidetector computed tomography (MDCT) in the diagnosis of pulmonary embolism: Interobserver agreement among radiologists with varied levels of experience
    • Ghanima W, Nielssen BE, Holmen LO et al (2007) Multidetector computed tomography (MDCT) in the diagnosis of pulmonary embolism: Interobserver agreement among radiologists with varied levels of experience. Acta Radiol 48:165-170
    • (2007) Acta Radiol , vol.48 , pp. 165-170
    • Ghanima, W.1    Nielssen, B.E.2    Holmen, L.O.3
  • 16
    • 26044460979 scopus 로고    scopus 로고
    • Reproducibility of multi-detector spiral computed tomography in detection of sub-segmental acute pulmonary embolism
    • Brunot S, Corneloup O, Latrabe V et al (2005) Reproducibility of multi-detector spiral computed tomography in detection of sub-segmental acute pulmonary embolism. Eur Radiol 15:2057-2063
    • (2005) Eur Radiol , vol.15 , pp. 2057-2063
    • Brunot, S.1    Corneloup, O.2    Latrabe, V.3
  • 17
    • 33644977678 scopus 로고    scopus 로고
    • Diagnosis and management of subsegmental pulmonary embolism
    • Le Gal G, Righini M, Parent F et al (2006) Diagnosis and management of subsegmental pulmonary embolism. J Thromb Haemost 4:724-731
    • (2006) J Thromb Haemost , vol.4 , pp. 724-731
    • Le Gal, G.1    Righini, M.2    Parent, F.3
  • 18
    • 20344396614 scopus 로고    scopus 로고
    • Preliminary investigation of computer-aided detection of pulmonary embolism in three-dimensional computed tomography pulmonary angiography images
    • Zhou C, Chan HP, Patel S et al (2005) Preliminary investigation of computer-aided detection of pulmonary embolism in three-dimensional computed tomography pulmonary angiography images. Acad Radiol 12:782-792
    • (2005) Acad Radiol , vol.12 , pp. 782-792
    • Zhou, C.1    Chan, H.P.2    Patel, S.3
  • 19
    • 0036999660 scopus 로고    scopus 로고
    • Computerized detection of pulmonary embolism in spiral CT angiography based on volumetric image analysis
    • Masutani Y, MacMahon H, Doi K et al (2002) Computerized detection of pulmonary embolism in spiral CT angiography based on volumetric image analysis. IEEE Trans Med Imaging 21:1517-1523
    • (2002) IEEE Trans Med Imaging , vol.21 , pp. 1517-1523
    • Masutani, Y.1    MacMahon, H.2    Doi, K.3
  • 20
    • 34548403882 scopus 로고    scopus 로고
    • Computer aided detection of pulmonary embolism with tobogganing and multiple instance classification in CT pulmonary angiography
    • Liang J, Bi J (2007) Computer aided detection of pulmonary embolism with tobogganing and multiple instance classification in CT pulmonary angiography. Inf Process Med Imaging 20:630-641
    • (2007) Inf Process Med Imaging , vol.20 , pp. 630-641
    • Liang, J.1    Bi, J.2
  • 21
    • 34250221160 scopus 로고    scopus 로고
    • Clinical evaluation of a computer-aided diagnosis (CAD) prototype for the detection of pulmonary embolism
    • Buhmann S, Herzog P, Liang J et al (2007) Clinical evaluation of a computer-aided diagnosis (CAD) prototype for the detection of pulmonary embolism. Acad Radiol 14:651-658
    • (2007) Acad Radiol , vol.14 , pp. 651-658
    • Buhmann, S.1    Herzog, P.2    Liang, J.3
  • 22
    • 39049099930 scopus 로고    scopus 로고
    • Computer-assisted detection of pulmonary embolism: Performance evaluation in consensus with experienced and inexperienced chest radiologists
    • [Epub ahead of print] DOI 10.1007/s00330-007-0770-3
    • Engelke C, Schmidt S, Bakai A, Auer F, Marten K (2007) Computer-assisted detection of pulmonary embolism: Performance evaluation in consensus with experienced and inexperienced chest radiologists. Eur Radiol Sep 28 [Epub ahead of print] DOI 10.1007/s00330-007-0770-3
    • (2007) Eur Radiol Sep , vol.28
    • Engelke, C.1    Schmidt, S.2    Bakai, A.3    Auer, F.4    Marten, K.5
  • 23
    • 36649003540 scopus 로고    scopus 로고
    • Pulmonary embolism: Computer-aided detection at multidetector row spiral computed tomography
    • Schoepf UJ, Schneider AC, Das M (2007) Pulmonary embolism: computer-aided detection at multidetector row spiral computed tomography. J Thorac Imaging 22:319-323
    • (2007) J Thorac Imaging , vol.22 , pp. 319-323
    • Schoepf, U.J.1    Schneider, A.C.2    Das, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.