메뉴 건너뛰기




Volumn 250, Issue , 2010, Pages 349-359

Gamma dose distribution evaluation tool

Author keywords

[No Author keywords available]

Indexed keywords

DOSE DISTRIBUTIONS; EVALUATION SOFTWARE; INTEGRAL COMPONENTS; MEDICAL PHYSICISTS; QUANTITATIVE COMPARISON; QUANTITATIVE EVALUATION; SPATIAL DIFFERENCES; STRAIGHT-FORWARD METHOD;

EID: 78650547165     PISSN: 17426588     EISSN: 17426596     Source Type: Conference Proceeding    
DOI: 10.1088/1742-6596/250/1/012071     Document Type: Conference Paper
Times cited : (80)

References (12)
  • 2
    • 7844245059 scopus 로고    scopus 로고
    • A software tool for the quantitative evaluation of 3D dose calculation algorithms
    • W. B. Harms, Sr., D. A. Low, J. W. Wong, and J. A. Purdy, "A software tool for the quantitative evaluation of 3D dose calculation algorithms," Med Phys. 25, 1830-1836 (1998).
    • (1998) Med Phys , vol.25 , pp. 1830-1836
    • Harms Sr., W.B.1    Low, D.A.2    Wong, J.W.3    Purdy, J.A.4
  • 4
    • 0029934826 scopus 로고    scopus 로고
    • Systematic verification of a three-dimensional electron beam dose calculation algorithm
    • A. Cheng, W. B. Harms, Sr., R. L. Gerber, J. W. Wong, and J. A. Purdy, "Systematic verification of a three-dimensional electron beam dose calculation algorithm," Med Phys. 23, 685-693 (1996).
    • (1996) Med Phys , vol.23 , pp. 685-693
    • Cheng, A.1    Harms Sr., W.B.2    Gerber, R.L.3    Wong, J.W.4    Purdy, J.A.5
  • 5
    • 0141520680 scopus 로고    scopus 로고
    • Evaluation of the gamma dose distribution comparison method
    • D. A. Low and J. F. Dempsey, "Evaluation of the gamma dose distribution comparison method," Medical Physics. 30, 2455-2464 (2003).
    • (2003) Medical Physics , vol.30 , pp. 2455-2464
    • Low, D.A.1    Dempsey, J.F.2
  • 6
    • 0036227283 scopus 로고    scopus 로고
    • A quantitative evaluation of IMRT dose distributions: Refinement and clinical assessment of the gamma evaluation
    • T. Depuydt, A. Van Esch, and D. P. Huyskens, "A quantitative evaluation of IMRT dose distributions: refinement and clinical assessment of the gamma evaluation," Radiotherapy and Oncology. 62, 309-319 (2002).
    • (2002) Radiotherapy and Oncology , vol.62 , pp. 309-319
    • Depuydt, T.1    Van Esch, A.2    Huyskens, D.P.3
  • 8
    • 14544300121 scopus 로고    scopus 로고
    • Interpretation and evaluation of the gamma index and the gamma index angle for the verification of IMRT hybrid plans
    • M. Stock, B. Kroupa, and D. Georg, "Interpretation and evaluation of the gamma index and the gamma index angle for the verification of IMRT hybrid plans," Physics in Medicine and Biology. 50, 399-411 (2005).
    • (2005) Physics in Medicine and Biology , vol.50 , pp. 399-411
    • Stock, M.1    Kroupa, B.2    Georg, D.3
  • 9
    • 33745001218 scopus 로고    scopus 로고
    • Gamma histograms for radiotherapy plan evaluation
    • E. Spezi and D. G. Lewis, "Gamma histograms for radiotherapy plan evaluation," Radiotherapy and Oncology. 79, 224-230 (2006).
    • (2006) Radiotherapy and Oncology , vol.79 , pp. 224-230
    • Spezi, E.1    Lewis, D.G.2
  • 12
    • 40049094995 scopus 로고    scopus 로고
    • Geometric interpretation of the gamma dose distribution comparison technique: Interpolation-free calculation
    • T. Ju, T. Simpson, J. O. Deasy, and D. A. Low, "Geometric interpretation of the gamma dose distribution comparison technique: Interpolation-free calculation," Medical Physics. 35, 879-887 (2008).
    • (2008) Medical Physics , vol.35 , pp. 879-887
    • Ju, T.1    Simpson, T.2    Deasy, J.O.3    Low, D.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.