-
1
-
-
0025975407
-
Clinical electron-beam dosimetry
-
American Association of Physicists in Medicine, RTC Task Group 25, "Clinical electron-beam dosimetry," Med. Phys. 18, 73-109 (1991).
-
(1991)
Med. Phys.
, vol.18
, pp. 73-109
-
-
-
2
-
-
33744584328
-
Broad beam approaches to dose computation and their limitations
-
edited by A. E. Nahum Umea University, Kungalv
-
P. Andreo, "Broad beam approaches to dose computation and their limitations," in The Computation of Dose Distributions in Electron Beam Radiotherapy, edited by A. E. Nahum (Umea University, Kungalv, 1985), pp. 128-150.
-
(1985)
The Computation of Dose Distributions in Electron Beam Radiotherapy
, pp. 128-150
-
-
Andreo, P.1
-
3
-
-
33744616431
-
High energy electron treatment planning for inhomogeneities
-
J. S. Laughlin, "High energy electron treatment planning for inhomogeneities," Br. J. Radiol. 38, 143-147 (1965).
-
(1965)
Br. J. Radiol.
, vol.38
, pp. 143-147
-
-
Laughlin, J.S.1
-
5
-
-
84907111624
-
Electron beam dose planning using discrete Gaussian beams: Mathematical background
-
A. Brahme, I. Lax, and P. Andreo, "Electron beam dose planning using discrete Gaussian beams: Mathematical background," Acta Radiol. Oncol. 20, 147-157 (1981).
-
(1981)
Acta Radiol. Oncol.
, vol.20
, pp. 147-157
-
-
Brahme, A.1
Lax, I.2
Andreo, P.3
-
6
-
-
0019523286
-
Electron beam dose calculations
-
K. R. Hogstrom, M. D. Mills, and P. R. Almond, "Electron beam dose calculations," Phys. Med. Biol. 26, 445-459 (1981).
-
(1981)
Phys. Med. Biol.
, vol.26
, pp. 445-459
-
-
Hogstrom, K.R.1
Mills, M.D.2
Almond, P.R.3
-
7
-
-
0002836335
-
Evaluation of electron pencil beam dose calculations
-
Proceedings of the 1986 Summer School of the AAPM, edited by H. Elson and C. Born American Institute of Physics, New York
-
K. R. Hogstrom, "Evaluation of electron pencil beam dose calculations," in Radiation Oncology Physics - 1986, Proceedings of the 1986 Summer School of the AAPM, edited by H. Elson and C. Born (American Institute of Physics, New York, 1987), pp. 532-557.
-
(1987)
Radiation Oncology Physics - 1986
, pp. 532-557
-
-
Hogstrom, K.R.1
-
8
-
-
14444280269
-
Computer dose calculation algorithms for electron beams
-
AAPM Monograph No. 19, edited by J. A. Purdy American Institute of Physics, New York
-
K. R. Hogstrom, G. Starkschall, and A. S. Shiu, "Computer dose calculation algorithms for electron beams," in Advances in Radiation Oncology Physics: Dosimetry, Treatment Planning, and Brachytherapy, AAPM Monograph No. 19, edited by J. A. Purdy (American Institute of Physics, New York, 1987), pp. 900-924.
-
(1987)
Advances in Radiation Oncology Physics: Dosimetry, Treatment Planning, and Brachytherapy
, pp. 900-924
-
-
Hogstrom, K.R.1
Starkschall, G.2
Shiu, A.S.3
-
10
-
-
0020973738
-
Electron beam dose planning using Gaussian beams: Improved radical dose profiles
-
I. Lax, A. Brahme, and P. Andreo, "Electron beam dose planning using Gaussian beams: Improved radical dose profiles," Acta Radiol. Suppl. 364, 49-59 (1983).
-
(1983)
Acta Radiol. Suppl.
, vol.364
, pp. 49-59
-
-
Lax, I.1
Brahme, A.2
Andreo, P.3
-
11
-
-
0018819515
-
A model for calculating the effects of small inhomogeneities on electron beam dose distribution
-
D. J. Perry and J. G. Holt, "A model for calculating the effects of small inhomogeneities on electron beam dose distribution," Med. Phys. 7, 207-215 (1980).
-
(1980)
Med. Phys.
, vol.7
, pp. 207-215
-
-
Perry, D.J.1
Holt, J.G.2
-
12
-
-
0026710885
-
Verification data for electron beam dose algorithms
-
A. S. Shiu, S. Tung, K. R. Hogstrom, J. W. Wong, R. L. Gerber, W. B. Harms, J. A. Purdy, R. K. Ten Haken, D. L. McShan, and B. A. Fraass, "Verification data for electron beam dose algorithms," Med. Phys. 19, 623-636 (1992).
-
(1992)
Med. Phys.
, vol.19
, pp. 623-636
-
-
Shiu, A.S.1
Tung, S.2
Hogstrom, K.R.3
Wong, J.W.4
Gerber, R.L.5
Harms, W.B.6
Purdy, J.A.7
Ten Haken, R.K.8
McShan, D.L.9
Fraass, B.A.10
-
13
-
-
85167001883
-
Final report on the evaluation of treatment planning for electron external beam treatment planning
-
B. A. Fraass, K. R. Hogstrom, and J. A. Purdy, "Final report on the evaluation of treatment planning for electron external beam treatment planning," NCI, 1989.
-
(1989)
NCI
-
-
Fraass, B.A.1
Hogstrom, K.R.2
Purdy, J.A.3
-
14
-
-
0026056690
-
Effect of dimensionality of heterogeneity corrections on three dimensional electron pencil beam calculations
-
G. Starkschall, K. R. Hogstrom, S. W. Bujnowski, L. Wang, and A. S. Shiu, "Effect of dimensionality of heterogeneity corrections on three dimensional electron pencil beam calculations," Phys. Med. Biol. 36, 207-227 (1991).
-
(1991)
Phys. Med. Biol.
, vol.36
, pp. 207-227
-
-
Starkschall, G.1
Hogstrom, K.R.2
Bujnowski, S.W.3
Wang, L.4
Shiu, A.S.5
-
15
-
-
85167028056
-
A systematic verification of a 3-D electron beam dose calculation algorithm (abstract)
-
A. Cheng, W. B. Harms, R. L. Gerber, J. W. Wong, and J. A. Purdy, "A systematic verification of a 3-D electron beam dose calculation algorithm (abstract)," Med. Phys. 20, 925 (1993).
-
(1993)
Med. Phys.
, vol.20
, pp. 925
-
-
Cheng, A.1
Harms, W.B.2
Gerber, R.L.3
Wong, J.W.4
Purdy, J.A.5
-
16
-
-
0023631671
-
Electron dose distributions in experimental phantoms: A comparison with 2D pencil beam calculations
-
J. Cygler, J. J. Battista, J. W. Scrimger, E. Mah, and J. Antolak, "Electron dose distributions in experimental phantoms: A comparison with 2D pencil beam calculations," Phys. Med. Biol. 32, 1073-1086 (1987).
-
(1987)
Phys. Med. Biol.
, vol.32
, pp. 1073-1086
-
-
Cygler, J.1
Battista, J.J.2
Scrimger, J.W.3
Mah, E.4
Antolak, J.5
-
17
-
-
0021256061
-
Dosimetric evaluation of a pencil-beam algorithm for electrons employing a 2-D heterogeneity correction
-
K. R. Hogstrom, M. D. Mills, J. A. Meyer, J. R. Palta, D. E. Mellenberg, R. T. Meoz, and R. S. Fields, "Dosimetric evaluation of a pencil-beam algorithm for electrons employing a 2-D heterogeneity correction," Int. J. Radiat. Oncol. Biol. Phys. 10, 561-569 (1983).
-
(1983)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.10
, pp. 561-569
-
-
Hogstrom, K.R.1
Mills, M.D.2
Meyer, J.A.3
Palta, J.R.4
Mellenberg, D.E.5
Meoz, R.T.6
Fields, R.S.7
-
18
-
-
0027980188
-
Dosimetric verification of a 3-D electron pencil beam dose calculation algorithm
-
D. L. McShan, B. A. Fraass, and R. K. Ten Haken, "Dosimetric verification of a 3-D electron pencil beam dose calculation algorithm," Med. Phys. 21, 13-23 (1994).
-
(1994)
Med. Phys.
, vol.21
, pp. 13-23
-
-
McShan, D.L.1
Fraass, B.A.2
Ten Haken, R.K.3
-
19
-
-
0342724839
-
A quantitative dose calculation evaluation tool (abstract)
-
W. B. Harms, D. A. Low, and J. A. Purdy, "A quantitative dose calculation evaluation tool (abstract)," Int. J. Radiat. Oncol. Biol. Phys. 30 (Suppl.1), 187 (1994).
-
(1994)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.30
, Issue.1 SUPPL.
, pp. 187
-
-
Harms, W.B.1
Low, D.A.2
Purdy, J.A.3
-
20
-
-
0024347237
-
Experimental evaluation of a 2D and 3D electron pencil beam algorithm
-
E. Mah, J. Antolak, J. W. Scrimger, and J. J. Battista, "Experimental evaluation of a 2D and 3D electron pencil beam algorithm," Phys. Med. Biol. 24, 1179-1194 (1989).
-
(1989)
Phys. Med. Biol.
, vol.24
, pp. 1179-1194
-
-
Mah, E.1
Antolak, J.2
Scrimger, J.W.3
Battista, J.J.4
-
21
-
-
0027316070
-
Commissioning and quality assurance of treatment planning computers
-
J. Van Dyk, R. B. Barnett, J. E. Cygler, and P. C. Shragge, "Commissioning and quality assurance of treatment planning computers," Int. J. Radial. Oncol. Biol. Phys. 26, 261-273 (1992).
-
(1992)
Int. J. Radial. Oncol. Biol. Phys.
, vol.26
, pp. 261-273
-
-
Van Dyk, J.1
Barnett, R.B.2
Cygler, J.E.3
Shragge, P.C.4
-
22
-
-
0026013526
-
Pencil-beam redefinition algorithm for electron dose distributions
-
A. S. Shiu and K. R. Hogstrom, "Pencil-beam redefinition algorithm for electron dose distributions," Med. Phys. 18, 7-18 (1991).
-
(1991)
Med. Phys.
, vol.18
, pp. 7-18
-
-
Shiu, A.S.1
Hogstrom, K.R.2
|