메뉴 건너뛰기




Volumn 24, Issue 5, 2010, Pages 620-625

Application of an automated cardiopulmonary resuscitation device for kidney transplantation from uncontrolled donation after cardiac death donors in the emergency department

Author keywords

Automated CPR device; Cardiopulmonary resuscitation; Donation after cardiac death; Transplantation; Warm ischemic time

Indexed keywords

ADULT; AGED; ARTERIAL PRESSURE; ARTICLE; AUTOMATION; CADAVER KIDNEY; CARDIOPULMONARY RESUSCITATION DEVICE; CLINICAL ARTICLE; COOLING; EMERGENCY WARD; FEMALE; HEART DEATH; HUMAN; INTERMETHOD COMPARISON; ISCHEMIA; KIDNEY DONOR; KIDNEY TRANSPLANTATION; MALE; MEDICAL INSTRUMENTATION; PRIORITY JOURNAL; RESUSCITATION;

EID: 78650439881     PISSN: 09020063     EISSN: 13990012     Source Type: Journal    
DOI: 10.1111/j.1399-0012.2009.01140.x     Document Type: Article
Times cited : (12)

References (23)
  • 1
    • 78650448663 scopus 로고    scopus 로고
    • Tissue and/or organ donation in the field of acute medicine: a meditation based on fundamental understandings of medical care
    • Yukioka T. Tissue and/or organ donation in the field of acute medicine: a meditation based on fundamental understandings of medical care. J Jpn Ass Acute Med 2006: 17: 247.
    • (2006) J Jpn Ass Acute Med , vol.17 , pp. 247
    • Yukioka, T.1
  • 2
    • 44649086471 scopus 로고    scopus 로고
    • Experiences in the development of non-heart beating organ donation schema in a regional neurosciences intensive care unit
    • Thomas I, Caborn S, Manara AR. Experiences in the development of non-heart beating organ donation schema in a regional neurosciences intensive care unit. Br J Anaesth 2008: 100: 820.
    • (2008) Br J Anaesth , vol.100 , pp. 820
    • Thomas, I.1    Caborn, S.2    Manara, A.R.3
  • 3
    • 40449142309 scopus 로고    scopus 로고
    • Increasing organ donation after cardiac death by increasing DCD support among health care professionals: a case report
    • D'Alessandro AM, Peltier JW, Phelps JE et al. Increasing organ donation after cardiac death by increasing DCD support among health care professionals: a case report. Am J Transplant 2008: 8: 897.
    • (2008) Am J Transplant , vol.8 , pp. 897
    • D'Alessandro, A.M.1    Peltier, J.W.2    Phelps, J.E.3
  • 4
    • 40449141191 scopus 로고    scopus 로고
    • Understanding the antecedents of the acceptance of donation after cardiac death by healthcare professionals
    • D'Alessandro AM, Peltier JW, Phelps JE et al. Understanding the antecedents of the acceptance of donation after cardiac death by healthcare professionals. Crit Care Med 2008: 36: 1075.
    • (2008) Crit Care Med , vol.36 , pp. 1075
    • D'Alessandro, A.M.1    Peltier, J.W.2    Phelps, J.E.3
  • 5
    • 31044444156 scopus 로고    scopus 로고
    • Current results of an organ procurement organization effort to increase utilization of donors after cardiac death
    • D'Alessandro AM. Current results of an organ procurement organization effort to increase utilization of donors after cardiac death. Transplantation 2006: 81: 15.
    • (2006) Transplantation , vol.81 , pp. 15
    • D'Alessandro, A.M.1
  • 6
    • 27644492814 scopus 로고    scopus 로고
    • Single-center experience with liver transplantation from controlled non-heartbeating donors: a viable source of grafts
    • Muiesan P, Girlanda R, Jassem W et al. Single-center experience with liver transplantation from controlled non-heartbeating donors: a viable source of grafts. Ann Surg 2005: 242: 732.
    • (2005) Ann Surg , vol.242 , pp. 732
    • Muiesan, P.1    Girlanda, R.2    Jassem, W.3
  • 7
    • 33845704999 scopus 로고    scopus 로고
    • Application of machine perfusion preservation as a viability test for marginal kidney graft
    • Matsuno N, Konno O, Mejit A et al. Application of machine perfusion preservation as a viability test for marginal kidney graft. Transplantation 2006: 82: 1425.
    • (2006) Transplantation , vol.82 , pp. 1425
    • Matsuno, N.1    Konno, O.2    Mejit, A.3
  • 8
    • 58149354176 scopus 로고    scopus 로고
    • Successful kidney transplantation from donation after cardiac death using a load-distributing-band chest compression device during long warm ischemic time
    • Morozumi J, Sakurai E, Matsuno N et al. Successful kidney transplantation from donation after cardiac death using a load-distributing-band chest compression device during long warm ischemic time. Resuscitation 2009: 80: 278.
    • (2009) Resuscitation , vol.80 , pp. 278
    • Morozumi, J.1    Sakurai, E.2    Matsuno, N.3
  • 10
    • 58249089430 scopus 로고    scopus 로고
    • Machine perfusion or cold storage in deceased-donor kidney transplantation
    • Moers C, Smiths JM, Maathuis MH et al. Machine perfusion or cold storage in deceased-donor kidney transplantation. N Engl J Med 2009: 360: 7.
    • (2009) N Engl J Med , vol.360 , pp. 7
    • Moers, C.1    Smiths, J.M.2    Maathuis, M.H.3
  • 11
    • 33745242486 scopus 로고    scopus 로고
    • Outcomes of kidney transplants from non-heart-beating deceased donors as reported to the Japan Organ Transplant Network from April 1995-December 2003: a multi center report
    • Teraoka S, Nomoto K, Kikuchi K et al. Outcomes of kidney transplants from non-heart-beating deceased donors as reported to the Japan Organ Transplant Network from April 1995-December 2003: a multi center report. Clin Transplant 2004: 91.
    • (2004) Clin Transplant , pp. 91
    • Teraoka, S.1    Nomoto, K.2    Kikuchi, K.3
  • 12
    • 16544390517 scopus 로고    scopus 로고
    • Early graft function in kidney transplantation from non-heart-beating donors
    • Matsuno N, Tashiro J, Uchiyama M et al. Early graft function in kidney transplantation from non-heart-beating donors. Ann Transplant 2004: 9: 21.
    • (2004) Ann Transplant , vol.9 , pp. 21
    • Matsuno, N.1    Tashiro, J.2    Uchiyama, M.3
  • 13
    • 7444225703 scopus 로고    scopus 로고
    • Kidney transplantation from organ donors following cardiopulmonary death using extracorporeal membrane oxygenation support
    • i
    • Gravel MT, Arenas JD, Chenault R I i et al. Kidney transplantation from organ donors following cardiopulmonary death using extracorporeal membrane oxygenation support. Ann Transplant 2004: 9: 57.
    • (2004) Ann Transplant , vol.9 , pp. 57
    • Gravel, M.T.1    Arenas, J.D.2    Chenault I, R.3
  • 14
    • 19044397481 scopus 로고    scopus 로고
    • Expanding the donor pool: use of renal transplants from non-heart-beating donors supported with extracorporeal membrane oxygenation
    • Lee CY, Tsai MK, Ko WJ et al. Expanding the donor pool: use of renal transplants from non-heart-beating donors supported with extracorporeal membrane oxygenation. Clin Transplant 2005: 19: 383.
    • (2005) Clin Transplant , vol.19 , pp. 383
    • Lee, C.Y.1    Tsai, M.K.2    Ko, W.J.3
  • 15
    • 22544448389 scopus 로고    scopus 로고
    • Extracorporeal support for organ donation after cardiac death effectively expands the donor pool
    • Magliocca JF, Magee JC, Rowe SA et al. Extracorporeal support for organ donation after cardiac death effectively expands the donor pool. J Trauma 2005: 58: 1095.
    • (2005) J Trauma , vol.58 , pp. 1095
    • Magliocca, J.F.1    Magee, J.C.2    Rowe, S.A.3
  • 16
    • 78650450916 scopus 로고    scopus 로고
    • American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Circulation 2005: 112: IV47-50.
    • 2005 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Circulation 2005: 112: IV47-50.
    • (2005)
  • 17
    • 33745065872 scopus 로고    scopus 로고
    • Use of an automated, load-distributing band chest compression device for out-of-hospital cardiac arrest resuscitation
    • Ong ME, Ornato JP, Edwards DP et al. Use of an automated, load-distributing band chest compression device for out-of-hospital cardiac arrest resuscitation. JAMA 2006: 295: 2629.
    • (2006) JAMA , vol.295 , pp. 2629
    • Ong, M.E.1    Ornato, J.P.2    Edwards, D.P.3
  • 18
    • 33745101183 scopus 로고    scopus 로고
    • Manual chest compression vs use of an automated chest compression device during resuscitation following out-of-hospital cardiac arrest: a randomized trial
    • Hallstrom A, Rea TD, Sayre MR et al. Manual chest compression vs use of an automated chest compression device during resuscitation following out-of-hospital cardiac arrest: a randomized trial. JAMA 2006: 295: 2620.
    • (2006) JAMA , vol.295 , pp. 2620
    • Hallstrom, A.1    Rea, T.D.2    Sayre, M.R.3
  • 19
    • 33745114207 scopus 로고    scopus 로고
    • Manual vs device-assisted CPR: reconciling apparently contradictory results
    • Roger JL, James TN. Manual vs device-assisted CPR: reconciling apparently contradictory results. JAMA 2006: 295: 2661.
    • (2006) JAMA , vol.295 , pp. 2661
    • Roger, J.L.1    James, T.N.2
  • 20
    • 2542476114 scopus 로고    scopus 로고
    • Improved hemodynamic performance with a novel chest compression device during treatment of in-hospital cardiac arrest
    • Timerman S, Cardoso LF, Ramires JA et al. Improved hemodynamic performance with a novel chest compression device during treatment of in-hospital cardiac arrest. Resuscitation 2004: 61: 273.
    • (2004) Resuscitation , vol.61 , pp. 273
    • Timerman, S.1    Cardoso, L.F.2    Ramires, J.A.3
  • 22
    • 78650469179 scopus 로고    scopus 로고
    • Kidney transplantation from non-heart-beating donors: analysis of organ procurement and outcome
    • Nishikido M, Noguchi M, Koga S et al. Kidney transplantation from non-heart-beating donors: analysis of organ procurement and outcome. Transplant Proc 2004: 361: 888.
    • (2004) Transplant Proc , vol.361 , pp. 888
    • Nishikido, M.1    Noguchi, M.2    Koga, S.3
  • 23
    • 4344701864 scopus 로고    scopus 로고
    • Donation after cardiac death: the University of Wisconsin experience with renal transplantation
    • Cooper JT, Chin LT, Krieger NR et al. Donation after cardiac death: the University of Wisconsin experience with renal transplantation. Am J Transplant 2004: 4: 1490.
    • (2004) Am J Transplant , vol.4 , pp. 1490
    • Cooper, J.T.1    Chin, L.T.2    Krieger, N.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.