메뉴 건너뛰기




Volumn 100, Issue 2, 2005, Pages 512-519

Circumferential adjustment of ultrasound probe position to determine the optimal approach to the internal jugular vein: A noninvasive geometric study in adults

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANALYTIC METHOD; ANATOMICAL VARIATION; ARTICLE; CANNULATION; COMMON CAROTID ARTERY; CONTROLLED STUDY; DIAGNOSTIC APPROACH ROUTE; DIAGNOSTIC VALUE; FEMALE; GEOMETRY; HEAD MOVEMENT; HUMAN; IMAGE ANALYSIS; INTERNAL JUGULAR VEIN; LYMPH NODE; MAJOR CLINICAL STUDY; MALE; MECHANICAL PROBE; NON INVASIVE MEASUREMENT; OPTICAL RESOLUTION; PRIORITY JOURNAL; SURFACE PROPERTY; SURGICAL APPROACH; THYROID GLAND; ULTRASOUND;

EID: 19944430853     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1213/01.ANE.0000142115.94440.6C     Document Type: Article
Times cited : (20)

References (23)
  • 1
    • 0029906824 scopus 로고    scopus 로고
    • Ultrasound guidance for placement of central venous catheters: A meta-analysis of the literature
    • Randolph AG, Cook DJ, Gonzales CA, Pribble CG. Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature. Crit Care Med 1996;24:2053-8.
    • (1996) Crit Care Med , vol.24 , pp. 2053-2058
    • Randolph, A.G.1    Cook, D.J.2    Gonzales, C.A.3    Pribble, C.G.4
  • 2
    • 0036288586 scopus 로고    scopus 로고
    • Use of ultrasound to place central lines
    • Keenan SP. Use of ultrasound to place central lines. J Crit Care 2002;17:126-37.
    • (2002) J Crit Care , vol.17 , pp. 126-137
    • Keenan, S.P.1
  • 4
    • 0043234290 scopus 로고    scopus 로고
    • Ultrasonic locating devices for central venous cannulation: Meta-analysis
    • Hind D, Calvert N, McWilliams R, et al. Ultrasonic locating devices for central venous cannulation: meta-analysis. BMJ 2003;327:361-7.
    • (2003) BMJ , vol.327 , pp. 361-367
    • Hind, D.1    Calvert, N.2    McWilliams, R.3
  • 5
  • 7
    • 0036794171 scopus 로고    scopus 로고
    • Current practice of internal jugular venous cannulation in a university anesthesia department: Influence of operator experience on success of cannulation and arterial injury
    • Augoustides JG, Diaz D, Weiner J, et al. Current practice of internal jugular venous cannulation in a university anesthesia department: influence of operator experience on success of cannulation and arterial injury. J Cardiothorac Vasc Anesth 2002;16:567-71.
    • (2002) J Cardiothorac Vasc Anesth , vol.16 , pp. 567-571
    • Augoustides, J.G.1    Diaz, D.2    Weiner, J.3
  • 8
    • 0026700322 scopus 로고
    • The element of experience in internal jugular vein catheterization
    • Jobes DR. The element of experience in internal jugular vein catheterization. Anesth Analg 1992;75:643.
    • (1992) Anesth Analg , vol.75 , pp. 643
    • Jobes, D.R.1
  • 9
    • 0030057294 scopus 로고    scopus 로고
    • Internal jugular vein and carotid artery anatomic relation as determined by ultrasonography
    • Troianos CA, Kuwik RJ, Pasqual JR, et al. Internal jugular vein and carotid artery anatomic relation as determined by ultrasonography. Anesthesiology 1996;85:43-8.
    • (1996) Anesthesiology , vol.85 , pp. 43-48
    • Troianos, C.A.1    Kuwik, R.J.2    Pasqual, J.R.3
  • 10
    • 0345451017 scopus 로고    scopus 로고
    • US-guided puncture of the internal jugular vein: Complications and anatomic considerations
    • Gordon AC, Saliken JC, Johns D, et al. US-guided puncture of the internal jugular vein: complications and anatomic considerations. J Vasc Interv Radiol 1998;9:333-8.
    • (1998) J Vasc Interv Radiol , vol.9 , pp. 333-338
    • Gordon, A.C.1    Saliken, J.C.2    Johns, D.3
  • 11
    • 0026518699 scopus 로고
    • Ultrasound-facilitated central venous cannulation
    • Koski EMJ, Suhonen M, Mattila MA. Ultrasound-facilitated central venous cannulation. Crit Care Med 1992;20:424-6.
    • (1992) Crit Care Med , vol.20 , pp. 424-426
    • Koski, E.M.J.1    Suhonen, M.2    Mattila, M.A.3
  • 12
    • 0027211861 scopus 로고
    • Is the internal jugular vein cannulated during insertion or withdrawal of the needle during central venous cannulation?
    • Mangar D, Turnage WS, Mohamed SA. Is the internal jugular vein cannulated during insertion or withdrawal of the needle during central venous cannulation? Anesth Analg 1993;76:1375.
    • (1993) Anesth Analg , vol.76 , pp. 1375
    • Mangar, D.1    Turnage, W.S.2    Mohamed, S.A.3
  • 13
    • 0033030363 scopus 로고    scopus 로고
    • Position of the internal jugular vein in children: A study of the anatomy using ultrasonography
    • Mallinson C, Bennett J, Hodgson P, Petros AJ. Position of the internal jugular vein in children: a study of the anatomy using ultrasonography. Paediatr Anaesth 1999;9:111-4.
    • (1999) Paediatr Anaesth , vol.9 , pp. 111-114
    • Mallinson, C.1    Bennett, J.2    Hodgson, P.3    Petros, A.J.4
  • 14
    • 0027472273 scopus 로고
    • Use of ultrasound to evaluate internal jugular vein anatomy and to facilitate central venous cannulation in paediatric patients
    • Alderson PJ, Burrows FA, Stemp LI, Holtby HM. Use of ultrasound to evaluate internal jugular vein anatomy and to facilitate central venous cannulation in paediatric patients. Br J Anaesth 1993;70:145-8.
    • (1993) Br J Anaesth , vol.70 , pp. 145-148
    • Alderson, P.J.1    Burrows, F.A.2    Stemp, L.I.3    Holtby, H.M.4
  • 15
    • 0030029633 scopus 로고    scopus 로고
    • Head rotation during internal jugular vein cannulation and the risk of carotid artery puncture
    • Sulek CA, Gravenstein N, Blackshear RH, Weiss L. Head rotation during internal jugular vein cannulation and the risk of carotid artery puncture. Anesth Analg 1996;82:125-8.
    • (1996) Anesth Analg , vol.82 , pp. 125-128
    • Sulek, C.A.1    Gravenstein, N.2    Blackshear, R.H.3    Weiss, L.4
  • 16
    • 0031962604 scopus 로고    scopus 로고
    • Anatomical variation of the internal jugular vein and its impact on temporary haemodialysis vascular access: An ultrasonographic survey in uraemic patients
    • Lin BS, Kong CW, Tarng DC, et al. Anatomical variation of the internal jugular vein and its impact on temporary haemodialysis vascular access: an ultrasonographic survey in uraemic patients. Nephrol Dial Transplant 1998;13:134-8.
    • (1998) Nephrol Dial Transplant , vol.13 , pp. 134-138
    • Lin, B.S.1    Kong, C.W.2    Tarng, D.C.3
  • 17
    • 0027352171 scopus 로고
    • Radiologic placement of long-term central venous catheters: A review
    • Mauro MA, Jaques PF. Radiologic placement of long-term central venous catheters: a review. J Vasc Interv Radiol 1993;4:127-37.
    • (1993) J Vasc Interv Radiol , vol.4 , pp. 127-137
    • Mauro, M.A.1    Jaques, P.F.2
  • 18
    • 0027194079 scopus 로고
    • Ultrasound-assisted cannulation of the internal jugular vein: A prospective comparison to the external landmark-guided technique
    • Denys BG, Uretsky BF, Reddy PS. Ultrasound-assisted cannulation of the internal jugular vein: a prospective comparison to the external landmark-guided technique. Circulation 1993;87:1557-62.
    • (1993) Circulation , vol.87 , pp. 1557-1562
    • Denys, B.G.1    Uretsky, B.F.2    Reddy, P.S.3
  • 19
    • 0031862926 scopus 로고    scopus 로고
    • Central venous access: Low internal jugular vein approach using imaging guidance
    • Silberzweig JE, Mitty HA. Central venous access: low internal jugular vein approach using imaging guidance. AJR Am J Roentgenol 1998;170:1617-20.
    • (1998) AJR Am J Roentgenol , vol.170 , pp. 1617-1620
    • Silberzweig, J.E.1    Mitty, H.A.2
  • 20
    • 0035089918 scopus 로고    scopus 로고
    • The internal jugular veins are asymmetric: Usefulness of ultrasound before catheterization
    • Lichtenstein D, Saifi R, Augarde R, et al. The internal jugular veins are asymmetric: usefulness of ultrasound before catheterization. Crit Care Med 2001;27:301-5.
    • (2001) Crit Care Med , vol.27 , pp. 301-305
    • Lichtenstein, D.1    Saifi, R.2    Augarde, R.3
  • 21
    • 0027417387 scopus 로고
    • A newly designed curved needle for percutaneous cannulation of the internal jugular vein
    • Oshima E, Ishizu K, Urabe N. A newly designed curved needle for percutaneous cannulation of the internal jugular vein. Anesthesiology 1993;78:792-3.
    • (1993) Anesthesiology , vol.78 , pp. 792-793
    • Oshima, E.1    Ishizu, K.2    Urabe, N.3
  • 22
    • 0029818750 scopus 로고    scopus 로고
    • Head rotation during internal jugular vein cannulation and risk of carotid artery puncture
    • Daniel M. Head rotation during internal jugular vein cannulation and risk of carotid artery puncture. Anesth Analg 1996;83:660.
    • (1996) Anesth Analg , vol.83 , pp. 660
    • Daniel, M.1
  • 23
    • 0026468283 scopus 로고
    • The Groshong catheter: Initial experience and early results of imaging-guided placement
    • Hull JE, Hunter CS, Luiken GA. The Groshong catheter: initial experience and early results of imaging-guided placement. Radiology 1992;185:803-7.
    • (1992) Radiology , vol.185 , pp. 803-807
    • Hull, J.E.1    Hunter, C.S.2    Luiken, G.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.