메뉴 건너뛰기




Volumn 15, Issue 6, 2010, Pages 838-846

Design of noncontact tumor imager for video-assisted thoracic surgery

Author keywords

Air jet; clinical application; lungs; noncontact stiffness sensor; video assisted thoracic surgery (VATS)

Indexed keywords

AIR JET; CLINICAL APPLICATION; LUNGS; NON-CONTACT; THORACIC SURGERY;

EID: 78650356902     PISSN: 10834435     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMECH.2010.2078830     Document Type: Article
Times cited : (10)

References (27)
  • 2
    • 0033756993 scopus 로고    scopus 로고
    • Better pulmonary function and prognosis with video-assisted thoracic surgery than with thoracotomy
    • S. Kaseda, T. Aoki, N. Hangai, and and K. Shimizu, "Better pulmonary function and prognosis with video-assisted thoracic surgery than with thoracotomy," Ann. Thorac. Surg., vol. 70, pp. 1644-1646, 2000.
    • (2000) Ann. Thorac. Surg. , vol.70 , pp. 1644-1646
    • Kaseda, S.1    Aoki, T.2    Hangai, N.3    Shimizu, K.4
  • 3
    • 0035190772 scopus 로고    scopus 로고
    • Surgery for non-small cell lung cancer-new trends
    • D. A. Waller, "Surgery for non-small cell lung cancer-new trends," Lung Cancer, vol. 34, pp. S133-S136, 2001.
    • (2001) Lung Cancer , vol.34
    • Waller, D.A.1
  • 4
    • 0032914748 scopus 로고    scopus 로고
    • Video-assisted thoracoscopic surgery for small indeterminate pulmonary nodules: Indications for preoperative marking
    • K. Suzuki,K.Nagai, J.Yoshida, H. Ohmatsu, K. Takahashi, M. Nishimura, andY.Nishiwaki, "Video-assisted thoracoscopic surgery for small indeterminate pulmonary nodules: Indications for preoperative marking," Chest, vol. 115, pp. 563-568, 1999.
    • (1999) Chest , vol.115 , pp. 563-568
    • Suzuki, K.1    Nagai, K.2    Yoshida, J.3    Ohmatsu, H.4    Takahashi, K.5    Nishimura, M.6    Nishiwaki, Y.7
  • 9
    • 34548665063 scopus 로고    scopus 로고
    • Simulating 3-D lung dynamics using a programmable graphics proccessing unit
    • Sep.
    • A. P. Santhanam, F. G. Hamza-Lup, and P. Rolland, "Simulating 3-D lung dynamics using a programmable graphics proccessing unit," IEEE Trans. Inf. Technol. Biomed., vol. 11, no. 5, pp. 497-506, Sep. 2007.
    • (2007) IEEE Trans. Inf. Technol. Biomed. , vol.11 , Issue.5 , pp. 497-506
    • Santhanam, A.P.1    Hamza-Lup, F.G.2    Rolland, P.3
  • 12
    • 49949121410 scopus 로고
    • The contact-impedance meter - 1
    • C. Kleesattel and G. M. L. Gladwell, "The contact-impedance meter - 1," Ultrasonics, vol. 6, pp. 175-180, 1968.
    • (1968) Ultrasonics , vol.6 , pp. 175-180
    • Kleesattel, C.1    Gladwell, G.M.L.2
  • 13
    • 0026938164 scopus 로고
    • New tactile sensor like the human hand and its applications
    • S. Omata and Y. Terunuma, "New tactile sensor like the human hand and its applications," Sens. Actuators A, vol. 35, pp. 9-15, 1992.
    • (1992) Sens. Actuators A , vol.35 , pp. 9-15
    • Omata, S.1    Terunuma, Y.2
  • 14
    • 0030780923 scopus 로고    scopus 로고
    • Mechanical impedance of layered tissue
    • H. Oka and T. Irie, "Mechanical impedance of layered tissue," Med. Progr. Through Technol., vol. 21, pp. 1-4, 1997.
    • (1997) Med. Progr. Through Technol. , vol.21 , pp. 1-4
    • Oka, H.1    Irie, T.2
  • 15
    • 36349028026 scopus 로고    scopus 로고
    • Tactile imaging system for localizing lung nodules during video assisted thoracoscopic surgery
    • A. P. Miller, W. J. Peine, J. S. Son, and Z. T. Hammoud, "Tactile imaging system for localizing lung nodules during video assisted thoracoscopic surgery," in Proc. IEEE Int. Conf. Robot. Autom., 2007, pp. 2996-3001.
    • (2007) Proc. IEEE Int. Conf. Robot. Autom. , pp. 2996-3001
    • Miller, A.P.1    Peine, W.J.2    Son, J.S.3    Hammoud, Z.T.4
  • 16
    • 33646685963 scopus 로고    scopus 로고
    • Non-contact stiffness imager
    • T. Kawahara, S. Tanaka, and M. Kaneko, "Non-contact stiffness imager," Int. J. Robot. Res., vol. 25, no. 5-6, pp. 537-549, 2006.
    • (2006) Int. J. Robot. Res. , vol.25 , Issue.5-6 , pp. 537-549
    • Kawahara, T.1    Tanaka, S.2    Kaneko, M.3
  • 20
    • 63049089884 scopus 로고    scopus 로고
    • Tumor imager enhanced by phase shift: Application to VATS
    • (in Japanese)
    • T. Kawahara, C. Toya, I. Ishii, M. Kaneko, Y. Miyata, M. Okajima, and T. Asahara, "Tumor imager enhanced by phase shift: Application to VATS," J. JSCAS, vol. 8, no. 2, pp. 89-96, 2006 (in Japanese).
    • (2006) J. JSCAS , vol.8 , Issue.2 , pp. 89-96
    • Kawahara, T.1    Toya, C.2    Ishii, I.3    Kaneko, M.4    Miyata, Y.5    Okajima, M.6    Asahara, T.7
  • 23
    • 0002887869 scopus 로고
    • On the propagation of tremors over the surface of an elastic solid
    • H. Lamb, "On the propagation of tremors over the surface of an elastic solid," Phil. Trans. R. Soc. A, vol. 203, pp. 1-42, 1904.
    • (1904) Phil. Trans. R. Soc. A , vol.203 , pp. 1-42
    • Lamb, H.1
  • 26
    • 0001142955 scopus 로고
    • Space and time spectra of stationary stochasticwaves, with spatial reference to microtremors
    • K. Aki, "Space and time spectra of stationary stochasticwaves, with spatial reference to microtremors," Bull. Earthq. Res. Inst., vol. 35, pp. 415-456, 1957.
    • (1957) Bull. Earthq. Res. Inst. , vol.35 , pp. 415-456
    • Aki, K.1
  • 27
    • 0021638836 scopus 로고
    • Array estimators and the use ofmicroseisms for reconnaissance of sedimentary basins
    • M.W. Ansen and J. D. Henstridge, "Array estimators and the use ofmicroseisms for reconnaissance of sedimentary basins," Geophysics, vol. 49, pp. 1828-1837, 1984.
    • (1984) Geophysics , vol.49 , pp. 1828-1837
    • Ansen, M.W.1    Henstridge, J.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.