메뉴 건너뛰기




Volumn 56, Issue 11, 2010, Pages 2850-2859

Simultaneous quantitative measurement of gaseous species composition and solids volume fraction in a gas/solid flow

Author keywords

Bubble; Emulsion; Fiber optics; Fluidization; FT IR; Gaseous species composition; Infrared spectroscopy; Solids volume fraction

Indexed keywords

ABSORBANCE SPECTRUM; ABSORBANCES; BEAM INTENSITY; BUBBLE; BUBBLE PHASIS; FIBEROPTIC PROBES; FT-IR; FUEL MOLE FRACTIONS; GAS TRACERS; GAS/SOLID FLOW; GASEOUS SPECIES; IN-SITU MEASUREMENT; MOLAR FRACTIONS; NOVEL APPLICATIONS; PROOF OF CONCEPT; QUANTITATIVE MEASUREMENT; RELATIVE ERRORS; SOLIDS VOLUME FRACTION; SPECTROSCOPIC METHOD; TIME-AVERAGED; TRACER GAS;

EID: 78650343675     PISSN: 00011541     EISSN: 15475905     Source Type: Journal    
DOI: 10.1002/aic.12210     Document Type: Article
Times cited : (8)

References (41)
  • 1
    • 49549169343 scopus 로고
    • The local structure of gas fluidized beds-I. A statistically based measuring system
    • Werther J, Molerus O. The local structure of gas fluidized beds-I. A statistically based measuring system. Int J Multiphase Flow. 1973; 1: 103-122.
    • (1973) Int J Multiphase Flow. , vol.1 , pp. 103-122
    • Werther, J.1    Molerus, O.2
  • 2
    • 0028093974 scopus 로고
    • Experimental methods in fluidization research
    • Yates JG, Simons SRJ. Experimental methods in fluidization research. Int J Multiphase Flow. 1994; 20: 297-330.
    • (1994) Int J Multiphase Flow. , vol.20 , pp. 297-330
    • Yates, J.G.1    Simons, S.R.J.2
  • 3
    • 0342871694 scopus 로고    scopus 로고
    • The guarded capacitance probe-a tool for the measurement of solids flow patterns in a laboratory and industrial fluidized bed
    • Hage B, Werther J. The guarded capacitance probe-a tool for the measurement of solids flow patterns in a laboratory and industrial fluidized bed. Powder Technol. 1997; 93: 235-245.
    • (1997) Powder Technol. , vol.93 , pp. 235-245
    • Hage, B.1    Werther, J.2
  • 4
    • 84984104296 scopus 로고
    • An electroconductivity technique for the measurement of axial variation of hold-ups in three-phase fluidized beds
    • Begovich J, Watson JS. An electroconductivity technique for the measurement of axial variation of hold-ups in three-phase fluidized beds. AIChE J. 1978; 24: 351-354.
    • (1978) AIChE J. , vol.24 , pp. 351-354
    • Begovich, J.1    Watson, J.S.2
  • 5
    • 0028193845 scopus 로고
    • A conductivity technique for gas and solids holdup determination in three-phase reactors
    • Uribe-Salas A, Gomez CO, Finch JA. A conductivity technique for gas and solids holdup determination in three-phase reactors. Chem Eng Sci. 1994; 49: 1-10.
    • (1994) Chem Eng Sci. , vol.49 , pp. 1-10
    • Uribe-Salas, A.1    Gomez, C.O.2    Finch, J.A.3
  • 6
    • 34249734782 scopus 로고    scopus 로고
    • An electrical conductivity probe method for measuring the local solid holdup in a slurry system
    • Liu M, Wang T, Yu W, Wang J. An electrical conductivity probe method for measuring the local solid holdup in a slurry system. Chem Eng J. 2007; 132: 37-46.
    • (2007) Chem Eng J. , vol.132 , pp. 37-46
    • Liu, M.1    Wang, T.2    Yu, W.3    Wang, J.4
  • 8
    • 84975605127 scopus 로고
    • Optoelectronic technique for the characterization of high concentration gas-solid suspension
    • Cutolo A, Rendina I, Arena U, Marzocchella A, Massimilla L. Optoelectronic technique for the characterization of high concentration gas-solid suspension. Appl Opt. 1990; 29: 1317-1322.
    • (1990) Appl Opt. , vol.29 , pp. 1317-1322
    • Cutolo, A.1    Rendina, I.2    Arena, U.3    Marzocchella, A.4    Massimilla, L.5
  • 9
    • 0020193454 scopus 로고
    • Optical probe to detect both bubbles and suspended particles in a three-phase fluidized bed
    • Ishida M, Tanaka H. Optical probe to detect both bubbles and suspended particles in a three-phase fluidized bed. J Chem Eng Japan. 1982; 15: 389-391.
    • (1982) J Chem Eng Japan. , vol.15 , pp. 389-391
    • Ishida, M.1    Tanaka, H.2
  • 10
    • 78650357928 scopus 로고
    • Fluidization V
    • Ostergaard K, Sorensen A, editors., New York, Engineering Foundation,
    • Hu T, Yu B, Wang Y. Holdups and models of three phase fluidized beds. In: Ostergaard K, Sorensen A, editors. Fluidization V. New York: Engineering Foundation, 1986: 353.
    • (1986) Holdups and models of three phase fluidized beds , pp. 353
    • Hu, T.1    Yu, B.2    Wang, Y.3
  • 11
    • 54949154914 scopus 로고    scopus 로고
    • An evaluation of the solid hold-up distribution in a fluidized bed of nanoparticles using radioactive densitometry and fibre optics
    • Esmaeili B, Chaouki J, Dubois C. An evaluation of the solid hold-up distribution in a fluidized bed of nanoparticles using radioactive densitometry and fibre optics. Can J Chem Eng. 2008; 86: 543-552.
    • (2008) Can J Chem Eng. , vol.86 , pp. 543-552
    • Esmaeili, B.1    Chaouki, J.2    Dubois, C.3
  • 12
    • 0033045722 scopus 로고    scopus 로고
    • Hydrodynamic behaviour of slurry column at high solids concentrations
    • Gandhi B, Prakash A, Bergougnou MA. Hydrodynamic behaviour of slurry column at high solids concentrations. Powder Technol. 1999; 103: 80-94.
    • (1999) Powder Technol. , vol.103 , pp. 80-94
    • Gandhi, B.1    Prakash, A.2    Bergougnou, M.A.3
  • 13
    • 0031278090 scopus 로고    scopus 로고
    • Noninvasive tomographic and velocimetric monitoring of multiphase flows
    • Chaouki J, Larachi F, Duduković MP. Noninvasive tomographic and velocimetric monitoring of multiphase flows. Ind Eng Chem Res. 1997; 36: 4476-4503.
    • (1997) Ind Eng Chem Res. , vol.36 , pp. 4476-4503
    • Chaouki, J.1    Larachi, F.2    Duduković, M.P.3
  • 14
    • 0141573223 scopus 로고    scopus 로고
    • Verification of fluidized bed electrical capacitance tomography measurements with a fibre optic probe
    • Pugsley T, Tanfara H, Malcus S, Cui H, Chaouki J, Winters C. Verification of fluidized bed electrical capacitance tomography measurements with a fibre optic probe. Chem Eng Sci. 2003; 58: 3923-3934.
    • (2003) Chem Eng Sci. , vol.58 , pp. 3923-3934
    • Pugsley, T.1    Tanfara, H.2    Malcus, S.3    Cui, H.4    Chaouki, J.5    Winters, C.6
  • 16
    • 60649093475 scopus 로고    scopus 로고
    • Phase holdup measurements in a gas-liquid-solid circulating fluidized bed (GLSCFB) riser using electrical resistance tomography and optical fibre probe
    • Razzak SA, Barghi S, Zhu JX, Mi Y. Phase holdup measurements in a gas-liquid-solid circulating fluidized bed (GLSCFB) riser using electrical resistance tomography and optical fibre probe. Chem Eng J. 2009; 147: 210-218.
    • (2009) Chem Eng J. , vol.147 , pp. 210-218
    • Razzak, S.A.1    Barghi, S.2    Zhu, J.X.3    Mi, Y.4
  • 17
    • 0024499702 scopus 로고
    • Measurement of longitudinal distribution of solids holdup in a three-phase fluidized bed by ultrasonic technique
    • Uchida S, Okamura S, Katsumata T. Measurement of longitudinal distribution of solids holdup in a three-phase fluidized bed by ultrasonic technique. Can J Chem Eng. 1989; 67: 166-169.
    • (1989) Can J Chem Eng. , vol.67 , pp. 166-169
    • Uchida, S.1    Okamura, S.2    Katsumata, T.3
  • 18
    • 34247350310 scopus 로고    scopus 로고
    • Near-infrared spectroscopy applications in pharmaceutical analysis
    • Luypaert J, Massart DL, Vander Heyden Y. Near-infrared spectroscopy applications in pharmaceutical analysis. Talanta. 2007; 72: 865-883.
    • (2007) Talanta. , vol.72 , pp. 865-883
    • Luypaert, J.1    Massart, D.L.2    Vander Heyden, Y.3
  • 19
    • 34047149453 scopus 로고    scopus 로고
    • Process analytical technology: a strategy for keeping manufacturing viable in Australia
    • Swarbrick B. Process analytical technology: a strategy for keeping manufacturing viable in Australia. Vib Spectrosc. 2007; 44: 171-178.
    • (2007) Vib Spectrosc. , vol.44 , pp. 171-178
    • Swarbrick, B.1
  • 20
    • 3242802226 scopus 로고    scopus 로고
    • Diffuse reflection infrared spectroscopy (drifts): application to the in situ analysis of catalysts
    • Armaroli T, Bécue T, Gautier S. Diffuse reflection infrared spectroscopy (drifts): application to the in situ analysis of catalysts. Oil Gas Sci Technol. 2004; 59: 215-237.
    • (2004) Oil Gas Sci Technol. , vol.59 , pp. 215-237
    • Armaroli, T.1    Bécue, T.2    Gautier, S.3
  • 21
    • 34247192958 scopus 로고    scopus 로고
    • In situ infrared study of n-heptane isomerization over Pt/H-beta zeolites
    • Kondo JN, Yang S, Zhu Q, Inagaki S, Domen K. In situ infrared study of n-heptane isomerization over Pt/H-beta zeolites. J Catal. 2007; 248: 53-59.
    • (2007) J Catal. , vol.248 , pp. 53-59
    • Kondo, J.N.1    Yang, S.2    Zhu, Q.3    Inagaki, S.4    Domen, K.5
  • 22
  • 23
    • 0343826715 scopus 로고    scopus 로고
    • In-line moisture measurement during granulation with a four-wavelength near infrared sensor: an evaluation of particle size and binder effects
    • Rantanen J, Räsänen E, Tenhunen J, Känsäkoski M, Mannermaa J-P, Yliruusi J. In-line moisture measurement during granulation with a four-wavelength near infrared sensor: an evaluation of particle size and binder effects. Eur J Pharm Biopharm. 2000a; 50: 271-276.
    • (2000) Eur J Pharm Biopharm. , vol.50 , pp. 271-276
    • Rantanen, J.1    Räsänen, E.2    Tenhunen, J.3    Känsäkoski, M.4    Mannermaa, J.5    Yliruusi, J.6
  • 24
    • 0034057750 scopus 로고    scopus 로고
    • Use of the near-infrared reflectance method for measurement of moisture content during granulation
    • Rantanen J, Antikainen O, Mannermaa J-P, Yliruusi J. Use of the near-infrared reflectance method for measurement of moisture content during granulation. Pharm Dev Technol. 2000; 5: 209-217.
    • (2000) Pharm Dev Technol. , vol.5 , pp. 209-217
    • Rantanen, J.1    Antikainen, O.2    Mannermaa, J.3    Yliruusi, J.4
  • 27
    • 0033004401 scopus 로고    scopus 로고
    • Monitoring of a film coating process for tablets using near infrared reflectance spectrometry
    • Andersson M, Josefson M, Langkilde FW, Wahlund K-G. Monitoring of a film coating process for tablets using near infrared reflectance spectrometry. J Pharm Biomed Anal. 1999; 20: 27-37.
    • (1999) J Pharm Biomed Anal. , vol.20 , pp. 27-37
    • Andersson, M.1    Josefson, M.2    Langkilde, F.W.3    Wahlund, K.4
  • 28
    • 0028891911 scopus 로고
    • Determination of film-coated tablet parameters by near-infrared spectroscopy
    • Kirsch JD, Drennen JK. Determination of film-coated tablet parameters by near-infrared spectroscopy. J Pharm Biomed Anal. 1995; 13: 1273-1281.
    • (1995) J Pharm Biomed Anal. , vol.13 , pp. 1273-1281
    • Kirsch, J.D.1    Drennen, J.K.2
  • 29
    • 0030045439 scopus 로고    scopus 로고
    • Near-infrared spectroscopic monitoring of the film coating process
    • Kirsch JD, Drennen JK. Near-infrared spectroscopic monitoring of the film coating process. Pharm Res. 1996; 13: 234-237.
    • (1996) Pharm Res. , vol.13 , pp. 234-237
    • Kirsch, J.D.1    Drennen, J.K.2
  • 30
    • 13844315677 scopus 로고    scopus 로고
    • Time-resolved NIR spectroscopy for quantitative analysis of intact pharmaceutical tablets
    • Abrahamsson C, Johansson J, Andersson-Engels S, Svanberg S, Folestad S. Time-resolved NIR spectroscopy for quantitative analysis of intact pharmaceutical tablets. Anal Chem. 2005; 77: 1055-1059.
    • (2005) Anal Chem. , vol.77 , pp. 1055-1059
    • Abrahamsson, C.1    Johansson, J.2    Andersson-Engels, S.3    Svanberg, S.4    Folestad, S.5
  • 31
    • 0029894006 scopus 로고    scopus 로고
    • Automated system for the on-line monitoring or powder blending processes using near-infrared spectroscopy. Part I. system development and control
    • Hailey PA, Doherty P, Tapsell P, Oliver T, Aldridge PK. Automated system for the on-line monitoring or powder blending processes using near-infrared spectroscopy. Part I. system development and control. J Pharm Biomed Anal. 1996; 14: 551-559.
    • (1996) J Pharm Biomed Anal. , vol.14 , pp. 551-559
    • Hailey, P.A.1    Doherty, P.2    Tapsell, P.3    Oliver, T.4    Aldridge, P.K.5
  • 32
    • 0032582289 scopus 로고    scopus 로고
    • Automated system for the on-line monitoring of powder blending processes using near-infrared spectroscopy: Part II. Qualitative approaches to blend evaluation
    • Sonja Sekulic S, Wakeman J, Doherty P, Hailey PA. Automated system for the on-line monitoring of powder blending processes using near-infrared spectroscopy: Part II. Qualitative approaches to blend evaluation. J Pharm Biomed Anal. 1998; 17: 1285-1309.
    • (1998) J Pharm Biomed Anal. , vol.17 , pp. 1285-1309
    • Sonja Sekulic, S.1    Wakeman, J.2    Doherty, P.3    Hailey, P.A.4
  • 34
    • 0031009324 scopus 로고    scopus 로고
    • Process control and end-point determination of a fluid bed granulation by application of near infra-red spectroscopy
    • Frake P, Greenhalgh D, Grierson SM, Hempenstall JM, Rudd DR. Process control and end-point determination of a fluid bed granulation by application of near infra-red spectroscopy. Int J Pharm. 1997; 151: 75-80.
    • (1997) Int J Pharm. , vol.151 , pp. 75-80
    • Frake, P.1    Greenhalgh, D.2    Grierson, S.M.3    Hempenstall, J.M.4    Rudd, D.R.5
  • 35
    • 37249037023 scopus 로고    scopus 로고
    • Real-time monitoring of powder mixing in a convective blender using non-invasive reflectance NIR spectrometry
    • Bellamy LJ, Nordon A, Littlejohn D. Real-time monitoring of powder mixing in a convective blender using non-invasive reflectance NIR spectrometry. The Analyst. 2008; 133: 58-64.
    • (2008) The Analyst. , vol.133 , pp. 58-64
    • Bellamy, L.J.1    Nordon, A.2    Littlejohn, D.3
  • 38
    • 0035826302 scopus 로고    scopus 로고
    • Characterization of diffuse reflectance fiber probe sampling on moving solids using a Fourier transform near-infrared spectrometer
    • Berntsson O, Danielsson L-G, Folestad S. Characterization of diffuse reflectance fiber probe sampling on moving solids using a Fourier transform near-infrared spectrometer. Anal Chim Acta. 2001; 431: 125-131.
    • (2001) Anal Chim Acta. , vol.431 , pp. 125-131
    • Berntsson, O.1    Danielsson, L.2    Folestad, S.3
  • 39
    • 11044232183 scopus 로고    scopus 로고
    • NIR spectroscopy on moving solids using a scanning grating spectrometer-impact on multivariate process analysis
    • Andersson M, Svensson O, Folestad S, Josefson M, Wahlund K-G. NIR spectroscopy on moving solids using a scanning grating spectrometer-impact on multivariate process analysis. Chemometr Intell Lab Sys. 2005; 75: 1-11.
    • (2005) Chemometr Intell Lab Sys. , vol.75 , pp. 1-11
    • Andersson, M.1    Svensson, O.2    Folestad, S.3    Josefson, M.4    Wahlund, K.5
  • 40
    • 77953492461 scopus 로고    scopus 로고
    • Principles of Instrumental Analysis
    • 6th Ed., Independence, KY, Brooks Cole,
    • Skoog DA, Holler FJ, Crouch SR. Principles of Instrumental Analysis, 6th Ed. Independence, KY: Brooks Cole, 2006.
    • (2006)
    • Skoog, D.A.1    Holler, F.J.2    Crouch, S.R.3
  • 41
    • 0037293741 scopus 로고    scopus 로고
    • High temperature fluidized bed reactor: measurements, hydrodynamics and simulation
    • Cui H, Sauriol P, Chaouki J. High temperature fluidized bed reactor: measurements, hydrodynamics and simulation. Chem Eng Sci. 2003; 58: 1071-1077.
    • (2003) Chem Eng Sci. , vol.58 , pp. 1071-1077
    • Cui, H.1    Sauriol, P.2    Chaouki, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.