메뉴 건너뛰기




Volumn 26, Issue 4, 2010, Pages 411-421

Filtration effects due to bioassay cage design and screen type

Author keywords

Bioassay cages; spray filtration; spray flux

Indexed keywords

AEROSOL; AIR; ANIMAL; ANIMAL HOUSING; ARTICLE; BIOASSAY; INSTRUMENTATION; MOSQUITO; PHYSIOLOGY; TOXICITY TESTING;

EID: 78650317094     PISSN: 8756971X     EISSN: None     Source Type: Journal    
DOI: 10.2987/10-6031.1     Document Type: Article
Times cited : (16)

References (22)
  • 1
    • 84901387801 scopus 로고    scopus 로고
    • Standard E 1260: Standard test method for determining liquid drop size characteristics in a spray using optical nonimaging light-scattering instruments
    • ASTM American Society for Testing and Materials West Conshohocken, PA: American Society for Testing and Materials International
    • ASTM [American Society for Testing and Materials]. 2003. Standard E 1260: standard test method for determining liquid drop size characteristics in a spray using optical nonimaging light-scattering instruments. In: Annual book of ASTM standards. West Conshohocken, PA: American Society for Testing and Materials International.
    • (2003) Annual Book of ASTM Standards
  • 2
    • 76649124354 scopus 로고    scopus 로고
    • Standard E 1620: Standard terminology relating to liquid particles and atomization
    • ASTM [American Society for Testing and Materials West Conshohocken PA: American Society for Testing and Materials International
    • ASTM [American Society for Testing and Materials]. 2004. Standard E 1620: standard terminology relating to liquid particles and atomization. In: Annual book of ASTM standards. West Conshohocken, PA: American Society for Testing and Materials International.
    • (2004) Annual Book of ASTM Standards
  • 4
    • 77949561393 scopus 로고    scopus 로고
    • Caged mosquito bioassay: Studies on cage exposure pathways effects of mesh on pesticide filtration and mosquito containment
    • Bonds JAS, Greer M, Coughlin J, Venit P. 2010. Caged mosquito bioassay: studies on cage exposure pathways, effects of mesh on pesticide filtration, and mosquito containment. J Am Mosq Control Assoc 26:50-56.
    • (2010) J. Am. Mosq. Control Assoc. , vol.26 , pp. 50-56
    • Bonds, J.A.S.1    Greer, M.2    Coughlin, J.3    Venit, P.4
  • 5
    • 72949113233 scopus 로고    scopus 로고
    • Aerosol sampling: Comparison of two rotating impactors for field droplet sizing and volumetric measurements
    • Bonds JAS, Greer MJ, Fritz BK, Hoffmann WC. 2009. Aerosol sampling: comparison of two rotating impactors for field droplet sizing and volumetric measurements. J Am Mosq Control Assoc 25: 474-479.
    • (2009) J. Am. Mosq. Control Assoc. , vol.25 , pp. 474-479
    • Bonds, J.A.S.1    Greer, M.J.2    Fritz, B.K.3    Hoffmann, W.C.4
  • 6
    • 0024088053 scopus 로고
    • Effects of screen materials on droplet size frequency distribution of aerosols entering sentinel mosquito exposure tubes
    • Boobar LR, Dobson SE, Perich MJ, Darby WM, Nelson JH. 1988. Effects of screen materials on droplet size frequency distribution of aerosols entering sentinel mosquito exposure tubes. Med Vet Entomol 2:379-384.
    • (1988) Med. Vet. Entomol. , vol.2 , pp. 379-384
    • Boobar, L.R.1    Dobson, S.E.2    Perich, M.J.3    Darby, W.M.4    Nelson, J.H.5
  • 7
    • 0542417311 scopus 로고
    • The effect of test cage materials on ULV malathion evaluations
    • Breeland SG. 1970. The effect of test cage materials on ULV malathion evaluations. Mosq News 30:338-342.
    • (1970) Mosq. News , vol.30 , pp. 338-342
    • Breeland, S.G.1
  • 9
    • 0343904957 scopus 로고    scopus 로고
    • An evaluation of two field samplers for monitoring spray drift
    • Cooper JF, Smith DN, Dobson HM. 1996. An evaluation of two field samplers for monitoring spray drift. Crop Prot 15:249-257.
    • (1996) Crop Prot , vol.15 , pp. 249-257
    • Cooper, J.F.1    Smith, D.N.2    Dobson, H.M.3
  • 11
  • 12
    • 45849095666 scopus 로고    scopus 로고
    • Development of a system for determining collection efficiency of spray samplers
    • Fritz BK, Hoffmann WC. 2008b. Development of a system for determining collection efficiency of spray samplers. Appl Eng Agric 24:285-293.
    • (2008) Appl. Eng. Agric. , vol.24 , pp. 285-293
    • Fritz, B.K.1    Hoffmann, W.C.2
  • 13
    • 78650366457 scopus 로고
    • Statistical evaluation of ground applied ULV malathion on natural populations of aedes vexans and culex species
    • Geery PR, Holub RE, Keen RR. 1983. Statistical evaluation of ground applied ULV malathion on natural populations of Aedes vexans and Culex species. Mosq News 43:206-208.
    • (1983) Mosq News , vol.43 , pp. 206-208
    • Geery, P.R.1    Holub, R.E.2    Keen, R.R.3
  • 15
    • 30944453675 scopus 로고    scopus 로고
    • Comparison of three imaging systems for water-sensitive papers
    • Hoffmann WC, Hewitt AJ. 2005. Comparison of three imaging systems for water-sensitive papers. Appl Eng Agric 21:961-964.
    • (2005) Appl. Eng. Agric. , vol.21 , pp. 961-964
    • Hoffmann, W.C.1    Hewitt, A.J.2
  • 18
    • 0002856421 scopus 로고
    • The impaction of aerosol particles on cylinders spheres ribbons and discs
    • May KR, Clifford R. 1967. The impaction of aerosol particles on cylinders, spheres, ribbons, and discs. Ann Occup Hyg 10:83-95.
    • (1967) Ann. Occup. Hyg. , vol.10 , pp. 83-95
    • May, K.R.1    Clifford, R.2
  • 19
    • 0032140223 scopus 로고    scopus 로고
    • Air flow through porous screens: From theory to practical considerations
    • Miguel AF. 1998. Air flow through porous screens: from theory to practical considerations. Energy Build 28:63-69.
    • (1998) Energy Build. , vol.28 , pp. 63-69
    • Miguel, A.F.1
  • 20
    • 0000682209 scopus 로고
    • Spray drift and its measurement
    • Mathews GA, Hislop FC, eds Wallingford, United Kingdom: CAB International
    • Miller PCH. 1993. Spray drift and its measurement. In: Mathews GA, Hislop FC, eds. Application technology for crop protection. Wallingford, United Kingdom: CAB International. p 101-122.
    • (1993) Application Technology for Crop Protection , pp. 101-122
    • Miller, P.C.H.1
  • 21
    • 0542441224 scopus 로고
    • Adult mosquito kill and droplet size of ultralow volume ground aerosols of insecticides
    • Mount GA, Pierce NW. 1972. Adult mosquito kill and droplet size of ultralow volume ground aerosols of insecticides. Mosq News 32:354-357.
    • (1972) Mosq News , vol.32 , pp. 354-357
    • Mount, G.A.1    Pierce, N.W.2
  • 22
    • 75349083554 scopus 로고    scopus 로고
    • Using computational fluid dynamics simulations to determine pressure drop on woven screens
    • Teitel M. 2009. Using computational fluid dynamics simulations to determine pressure drop on woven screens. Biosystems Engr 105:172-179.
    • (2009) Biosystems Engr. , vol.105 , pp. 172-179
    • Teitel, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.