메뉴 건너뛰기




Volumn 15, Issue 6, 2010, Pages 300-304

Can sphygmomanometers designed for self-measurement of blood pressure in the home be used in office practice?

Author keywords

automated sphygmomanometers; blood pressure measurement; home blood pressure

Indexed keywords

ADULT; ARTICLE; AUTOMATED OFFICE BLOOD PRESSURE MEASUREMENT; BLOOD PRESSURE MEASUREMENT; BLOOD PRESSURE MONITORING; CLINICAL EVALUATION; CONTROLLED STUDY; CORRELATION COEFFICIENT; DIASTOLIC BLOOD PRESSURE; FEMALE; HOME MONITORING; HUMAN; HYPERTENSION; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; SELF EXAMINATION; SPHYGMOMANOMETER; SYSTOLIC BLOOD PRESSURE;

EID: 78650305801     PISSN: 13595237     EISSN: None     Source Type: Journal    
DOI: 10.1097/MBP.0b013e328340d128     Document Type: Article
Times cited : (37)

References (16)
  • 1
    • 26844562540 scopus 로고    scopus 로고
    • The BpTRU automatic blood pressure monitor compared to 24-h ambulatory blood pressure monitoring in the assessment of blood pressure in patients with hypertension
    • Beckett L, Godwin M. The BpTRU automatic blood pressure monitor compared to 24-h ambulatory blood pressure monitoring in the assessment of blood pressure in patients with hypertension. BMC Cardiovasc Disord 2005; 5:18.
    • (2005) BMC Cardiovasc Disord , vol.5 , pp. 18
    • Beckett, L.1    Godwin, M.2
  • 2
    • 63849254204 scopus 로고    scopus 로고
    • Use of automated office blood pressure measurement to reduce the white coat response
    • Myers MG, Valdivieso M, Kiss A. Use of automated office blood pressure measurement to reduce the white coat response. J Hypertens 2009; 27:280-286.
    • (2009) J Hypertens , vol.27 , pp. 280-286
    • Myers, M.G.1    Valdivieso, M.2    Kiss, A.3
  • 3
    • 0034959116 scopus 로고    scopus 로고
    • Evaluation of overall efficacy of the Omron office digital blood pressure HEM-907 monitor in adults
    • White WG, Anwar YA. Evaluation of overall efficacy of the Omron office digital blood pressure HEM-907 monitor in adults. Blood Press Monit 2001; 6:107-110.
    • (2001) Blood Press Monit , vol.6 , pp. 107-110
    • White, W.G.1    Anwar, Y.A.2
  • 4
    • 53549101912 scopus 로고    scopus 로고
    • Validation of Microlife WatchBP Office professional device for office blood pressure measurement according to the International Protocol
    • Stergiou GS, Tzamouranis D, Protogerou A, Nasothimiou E, Kapralos C. Validation of Microlife WatchBP Office professional device for office blood pressure measurement according to the International Protocol. Blood Press Monit 2008; 13:299-303.
    • (2008) Blood Press Monit , vol.13 , pp. 299-303
    • Stergiou, G.S.1    Tzamouranis, D.2    Protogerou, A.3    Nasothimiou, E.4    Kapralos, C.5
  • 6
    • 33744510715 scopus 로고    scopus 로고
    • Automated blood pressure measurement in routine clinical practice
    • Myers MG. Automated blood pressure measurement in routine clinical practice. Blood Press Monit 2006; 11:59-62.
    • (2006) Blood Press Monit , vol.11 , pp. 59-62
    • Myers, M.G.1
  • 7
    • 67649655955 scopus 로고    scopus 로고
    • Consistent relationship between automated office blood pressure recorded in different settings
    • Myers MG,Valdivieso M, Kiss A. Consistent relationship between automated office blood pressure recorded in different settings. Blood Press Monit 2009; 14:108-111.
    • (2009) Blood Press Monit , vol.14 , pp. 108-111
    • Myers, M.G.1    Valdivieso, M.2    Kiss, A.3
  • 8
    • 38349044223 scopus 로고    scopus 로고
    • Validation of Omron M7 (HEM-780-E) oscillometric blood pressure monitoring device according to the British Hypertension Society protocol
    • Coleman A, Steel S, Freeman P, De Greeff A, Shennan A. Validation of Omron M7 (HEM-780-E) oscillometric blood pressure monitoring device according to the British Hypertension Society protocol. Blood Press Monit 2008; 13:49-54.
    • (2008) Blood Press Monit , vol.13 , pp. 49-54
    • Coleman, A.1    Steel, S.2    Freeman, P.3    De Greeff, A.4    Shennan, A.5
  • 9
    • 33746112932 scopus 로고    scopus 로고
    • Validation of the Microlife BPA100 Plus device for self-home blood pressure measurement according to the International Protocol
    • Stergiou GS, Giovas PP, Neofytou MS, Adamopoulos DN. Validation of the Microlife BPA100 Plus device for self-home blood pressure measurement according to the International Protocol. Blood Press Monit 2006; 11:157-160.
    • (2006) Blood Press Monit , vol.11 , pp. 157-160
    • Stergiou, G.S.1    Giovas, P.P.2    Neofytou, M.S.3    Adamopoulos, D.N.4
  • 10
    • 0038621768 scopus 로고    scopus 로고
    • Performance of the UA-787 oscillometric blood pressure monitor according to the European Society of Hypertension protocol
    • Longo D, Toffanin G, Garbelotto R, Zaetta V, Businaro L, Palatini P. Performance of the UA-787 oscillometric blood pressure monitor according to the European Society of Hypertension protocol. Blood Press Monit 2003; 8:91-95.
    • (2003) Blood Press Monit , vol.8 , pp. 91-95
    • Longo, D.1    Toffanin, G.2    Garbelotto, R.3    Zaetta, V.4    Businaro, L.5    Palatini, P.6
  • 11
    • 51549098043 scopus 로고    scopus 로고
    • European Society of Hypertension guidelines for blood pressure monitoring at home: A summary report of the Second International Consensus Conference on Home Blood Pressure Monitoring
    • On behalf of the ESH Working Group on Blood Pressure Monitorinig
    • Parati G, Stergiou GS, Asmar R, Bilo G, De Leeuw P, Imai Y, et al.; On behalf of the ESH Working Group on Blood Pressure Monitorinig. European Society of Hypertension guidelines for blood pressure monitoring at home: a summary report of the Second International Consensus Conference on Home Blood Pressure Monitoring. J Hypertens 2008; 26:1505-1530
    • (2008) J Hypertens , vol.26 , pp. 1505-1530
    • Parati, G.1    Stergiou, G.S.2    Asmar, R.3    Bilo, G.4    De Leeuw, P.5    Imai, Y.6
  • 12
    • 0003473364 scopus 로고
    • Association for the Advancement of Medical Instrumentation 3330 Washington Boulevard, Arlington, Virginia, USA 22201: AAMI
    • Association for the Advancement of Medical Instrumentation. American national standard: electronic or automated sphygmomanometers. 3330 Washington Boulevard, Arlington, Virginia, USA, 22201: AAMI; 1993.
    • (1993) American National Standard: Electronic or Automated Sphygmomanometers
  • 13
    • 0035992025 scopus 로고    scopus 로고
    • With the statistical assistance of Atkins N and Gerin W on behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension: International protocol for validation of blood pressure measuring devices in adults
    • O'Brien E, Pickering T, Asmar R, Myers M, Parati G, Staessen J, et al. With the statistical assistance of Atkins N and Gerin W on behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension: international protocol for validation of blood pressure measuring devices in adults. Blood Press Monit 2002; 7:3-17.
    • (2002) Blood Press Monit , vol.7 , pp. 3-17
    • O'Brien, E.1    Pickering, T.2    Asmar, R.3    Myers, M.4    Parati, G.5    Staessen, J.6
  • 14
    • 40049101680 scopus 로고    scopus 로고
    • Comparison between an automated and manual sphygmomanometer in a population survey
    • Myers MG, McInnis NH, Fodor GJ, Leenen FHH. Comparison between an automated and manual sphygmomanometer in a population survey. Am J Hypertens 2008; 21:280-283.
    • (2008) Am J Hypertens , vol.21 , pp. 280-283
    • Myers, M.G.1    McInnis, N.H.2    Fodor, G.J.3    Leenen, F.H.H.4
  • 15
    • 74949121981 scopus 로고    scopus 로고
    • Measurement of blood pressure in the office. Recognizing the problem and proposing the solution
    • Myers MG, Godwin M, Dawes M, Kiss A, Tobe SW, Kaczorowski J. Measurement of blood pressure in the office. Recognizing the problem and proposing the solution. Hypertension 2010; 55:195-200.
    • (2010) Hypertension , vol.55 , pp. 195-200
    • Myers, M.G.1    Godwin, M.2    Dawes, M.3    Kiss, A.4    Tobe, S.W.5    Kaczorowski, J.6
  • 16
    • 77249174255 scopus 로고    scopus 로고
    • Are there really differences between home and daytime ambulatory blood pressure? Comparison using a novel dual-mode ambulatory and home monitor
    • Stergiou GS, Tzamouranis D, Nasothimiou EG, Karpettas N, Protogerou A. Are there really differences between home and daytime ambulatory blood pressure? Comparison using a novel dual-mode ambulatory and home monitor. J Hum Hypertens 2010; 24:207-212.
    • (2010) J Hum Hypertens , vol.24 , pp. 207-212
    • Stergiou, G.S.1    Tzamouranis, D.2    Nasothimiou, E.G.3    Karpettas, N.4    Protogerou, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.