메뉴 건너뛰기




Volumn 13, Issue 6, 2010, Pages 766-772

Biomechanics of polyaryletherketone rod composites and titanium rods for posterior lumbosacral instrumentation: Presented at the 2010 Joint Spine Section Meeting - Laboratory investigation

Author keywords

In vitro cadaver model; Lumbosacral instrumentation; Range of motion; Spinal stability; Stiffness

Indexed keywords

CARBON FIBER; MARKER; POLYARYLETHERETHERKETONE; POLYARYLETHERKETONE; POLYETHERETHERKETONE; TITANIUM; UNCLASSIFIED DRUG;

EID: 78650219968     PISSN: 15475654     EISSN: 15475646     Source Type: Journal    
DOI: 10.3171/2010.5.SPINE09948     Document Type: Article
Times cited : (59)

References (25)
  • 1
    • 58149504739 scopus 로고    scopus 로고
    • Comparison of the load-sharing characteristics between pedicle-based dynamic and rigid rod devices
    • Ahn YH, Chen WM, Lee KY, Park KW, Lee SJ: Comparison of the load-sharing characteristics between pedicle-based dynamic and rigid rod devices. Biomed Mater 3:044101, 2008
    • (2008) Biomed Mater , vol.3 , pp. 044101
    • Ahn, Y.H.1    Chen, W.M.2    Lee, K.Y.3    Park, K.W.4    Lee, S.J.5
  • 2
    • 0027423357 scopus 로고
    • A carbon fiber implant to aid interbody lumbar fusion. Two-year clinical results in the first 26 patients
    • Brantigan JW, Steffee AD: A carbon fiber implant to aid interbody lumbar fusion. Two-year clinical results in the first 26 patients. Spine 18:2106-2107, 1993
    • (1993) Spine , vol.18 , pp. 2106-2107
    • Brantigan, J.W.1    Steffee, A.D.2
  • 3
    • 0027485491 scopus 로고
    • The role of fusion and instrumentation in the treatment of degenerative spondylolisthesis with spinal stenosis
    • Bridwell KH, Sedgewick TA, O'Brien MF, Lenke LG, Baldus C: The role of fusion and instrumentation in the treatment of degenerative spondylolisthesis with spinal stenosis. J Spinal Disord 6:461-472, 1993 (Pubitemid 23360532)
    • (1993) Journal of Spinal Disorders , vol.6 , Issue.6 , pp. 461-472
    • Bridwell, K.H.1    Sedgewick, T.A.2    O'Brien, M.F.3    Lenke, L.G.4    Baldus, C.5
  • 4
  • 6
    • 48949099907 scopus 로고    scopus 로고
    • Internal and external responses of anterior lumbar/lumbosacral fusion: Nonlinear finite element analysis
    • Guan Y, Yoganandan N, Maiman DJ, Pintar FA: Internal and external responses of anterior lumbar/lumbosacral fusion: nonlinear finite element analysis. J Spinal Disord Tech 21:299-304, 2008
    • (2008) J Spinal Disord Tech , vol.21 , pp. 299-304
    • Guan, Y.1    Yoganandan, N.2    Maiman, D.J.3    Pintar, F.A.4
  • 8
    • 16544375789 scopus 로고    scopus 로고
    • The role of rigid vs. dynamic instrumentation for stabilization of the degenerative lumbosacral spine
    • Korovessis P, Papazisis Z, Lambiris E: The role of rigid vs. dynamic instrumentation for stabilization of the degenerative lumbosacral spine. Stud Health Technol Inform 91:457-461, 2002
    • (2002) Stud Health Technol Inform , vol.91 , pp. 457-461
    • Korovessis, P.1    Papazisis, Z.2    Lambiris, E.3
  • 9
    • 34548021405 scopus 로고    scopus 로고
    • PEEK biomaterials in trauma, orthopedic, and spinal implants
    • Kurtz SM, Devine JN: PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials 28:4845-4869, 2007
    • (2007) Biomaterials , vol.28 , pp. 4845-4869
    • Kurtz, S.M.1    Devine, J.N.2
  • 11
    • 0027139189 scopus 로고
    • Effects of anterior vertebral grafting on the traumatized lumbar spine after pedicle screw-plate fixation
    • Maiman DJ, Pintar F, Yoganandan N, Reinartz J: Effects of anterior vertebral grafting on the traumatized lumbar spine after pedicle screw-plate fixation. Spine 18:2423-2430, 1993 (Pubitemid 24001350)
    • (1993) Spine , vol.18 , Issue.16 , pp. 2423-2430
    • Maiman, D.J.1    Pintar, F.2    Yoganandan, N.3    Reinartz, J.4
  • 13
    • 0037239904 scopus 로고    scopus 로고
    • Dynamic stabilization of lumbar motion segments by use of Graf's ligaments: Results with an average follow-up of 7.4 years in 39 highly selected, consecutive patients
    • Markwalder TM, Wenger M: Dynamic stabilization of lumbar motion segments by use of Graf's ligaments: results with an average follow-up of 7.4 years in 39 highly selected, consecutive patients. Acta Neurochir (Wien) 145:209-214, 2003
    • (2003) Acta Neurochir (Wien) , vol.145 , pp. 209-214
    • Markwalder, T.M.1    Wenger, M.2
  • 14
    • 33750715113 scopus 로고    scopus 로고
    • Tapered cages in anterior lumbar interbody fusion: Biomechanics of segmental reactions
    • DOI 10.3171/spi.2006.5.4.330
    • Moore J, Yoganandan N, Pintar FA, Lifshutz J, Maiman DJ: Tapered cages in anterior lumbar interbody fusion: biomechanics of segmental reactions. J Neurosurg Spine 5:330-335, 2006 (Pubitemid 47325372)
    • (2006) Journal of Neurosurgery: Spine , vol.5 , Issue.4 , pp. 330-335
    • Moore, J.1    Yoganandan, N.2    Pintar, F.A.3    Lifshutz, J.4    Maiman, D.J.5
  • 15
  • 16
    • 63649135098 scopus 로고    scopus 로고
    • Biomechanical evaluation and comparison of polyetheretherketone rod system to traditional titanium rod fixation
    • Ponnappan RK, Serhan H, Zarda B, Patel R, Albert T, Vaccaro AR: Biomechanical evaluation and comparison of polyetheretherketone rod system to traditional titanium rod fixation. Spine J 9:263-267, 2009
    • (2009) Spine J , vol.9 , pp. 263-267
    • Ponnappan, R.K.1    Serhan, H.2    Zarda, B.3    Patel, R.4    Albert, T.5    Vaccaro, A.R.6
  • 17
    • 0023741286 scopus 로고
    • Composite technology for total hip arthroplasty
    • Skinner HB: Composite technology for total hip arthroplasty. Clin Orthop Relat Res (235):224-236, 1988
    • (1988) Clin Orthop Relat Res , Issue.235 , pp. 224-236
    • Skinner, H.B.1
  • 20
    • 0028344746 scopus 로고
    • Cyclic compression-flexion loading of the human lumbar spine
    • Yoganandan N, Cusick JF, Pintar FA, Droese K, Reinartz J: Cyclic compression-flexion loading of the human lumbar spine. Spine 19:784-791, 1994 (Pubitemid 24111360)
    • (1994) Spine , vol.19 , Issue.7 , pp. 784-791
    • Yoganandan, N.1    Cusick, J.F.2    Pintar, F.A.3    Droese, K.4    Reinartz, J.5
  • 21
    • 0035218103 scopus 로고    scopus 로고
    • Biomechanics of the cervical spine Part 2. Cervical spine soft tissue responses and biomechanical modeling
    • Yoganandan N, Kumaresan S, Pintar FA: Biomechanics of the cervical spine Part 2. Cervical spine soft tissue responses and biomechanical modeling. Clin Biomech (Bristol, Avon) 16:1-27, 2001
    • (2001) Clin Biomech (Bristol, Avon) , vol.16 , pp. 1-27
    • Yoganandan, N.1    Kumaresan, S.2    Pintar, F.A.3
  • 25
    • 37849049353 scopus 로고    scopus 로고
    • Biomechanics of unilateral compared with bilateral lumbar pedicle screw fixation for stabilization of unilateral vertebral disease. Laboratory investigation
    • Yücesoy K, Yüksel KZ, Baek S, Sonntag VK, Crawford NR: Biomechanics of unilateral compared with bilateral lumbar pedicle screw fixation for stabilization of unilateral vertebral disease. Laboratory investigation. J Neurosurg Spine 8:44-51, 2008
    • (2008) J Neurosurg Spine , vol.8 , pp. 44-51
    • Yücesoy, K.1    Yüksel, K.Z.2    Baek, S.3    Sonntag, V.K.4    Crawford, N.R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.