-
1
-
-
0033126563
-
Persistent periapical radiolucencies of root-filled human teeth, failed endodontic treatments, and periapical scars
-
P.N.R. Nair, U. Sjögren, D. Figdor, and G. Sundqvist Persistent periapical radiolucencies of root-filled human teeth, failed endodontic treatments, and periapical scars Oral Surg Oral Med Oral Pathol Oral Radiol Endod 87 1999 617 627
-
(1999)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.87
, pp. 617-627
-
-
Nair, P.N.R.1
Sjögren, U.2
Figdor, D.3
Sundqvist, G.4
-
2
-
-
77951634110
-
Influence of intracanal post on apical periodontitis identified by cone beam computed tomography
-
C. Estrela, M.R. Bueno, O.C.L. Porto, C.D. Rodrigues, and J.D. Pécora Influence of intracanal post on apical periodontitis identified by cone beam computed tomography Braz Dent J 20 2009 370 375
-
(2009)
Braz Dent J
, vol.20
, pp. 370-375
-
-
Estrela, C.1
Bueno, M.R.2
Porto, O.C.L.3
Rodrigues, C.D.4
Pécora, J.D.5
-
3
-
-
0027696854
-
Sealing ability of a mineral trioxide aggregate for repair of lateral root perforations
-
S.J. Lee, M. Monsef, and M. Torabinejad Sealing ability of a mineral trioxide aggregate for repair of lateral root perforations J Endod 19 1993 541 544
-
(1993)
J Endod
, vol.19
, pp. 541-544
-
-
Lee, S.J.1
Monsef, M.2
Torabinejad, M.3
-
4
-
-
0035317522
-
Mineral trioxide aggregate repair of root perforations
-
R. Holland, J.A. Otoboni-Filho, V. Souza, M.J. Nery, P.F.E. Bernabé, and E. Dezan Jr. Mineral trioxide aggregate repair of root perforations J Endod 27 2001 281 284
-
(2001)
J Endod
, vol.27
, pp. 281-284
-
-
Holland, R.1
Otoboni-Filho, J.A.2
Souza, V.3
Nery, M.J.4
Bernabé, P.F.E.5
Dezan Jr., E.6
-
5
-
-
74949118727
-
Mineral trioxide aggregate: A comprehensive literature review - Part II: Leakage and biocompatibility investigations
-
M. Torabinejad, and M. Parirokh Mineral trioxide aggregate: a comprehensive literature review - part II: leakage and biocompatibility investigations J Endod 36 2010 190 202
-
(2010)
J Endod
, vol.36
, pp. 190-202
-
-
Torabinejad, M.1
Parirokh, M.2
-
6
-
-
0015911128
-
Computerised transverse axial scanning (tomography): I - Description of system
-
G.N. Hounsfield Computerised transverse axial scanning (tomography): I - description of system Br J Radiol 46 1973 1016 1022
-
(1973)
Br J Radiol
, vol.46
, pp. 1016-1022
-
-
Hounsfield, G.N.1
-
7
-
-
0033156083
-
Development of a compact computed tomographic apparatus for dental use
-
Y. Arai, E. Tammisalo, K. Iwai, K. Hashimoto, and K. Shinoda Development of a compact computed tomographic apparatus for dental use Dentomaxillofac Radiol 28 1999 245 248
-
(1999)
Dentomaxillofac Radiol
, vol.28
, pp. 245-248
-
-
Arai, Y.1
Tammisalo, E.2
Iwai, K.3
Hashimoto, K.4
Shinoda, K.5
-
8
-
-
0032240404
-
A new volumetric CT machine for dental imaging based on the cone-beam technique: Preliminary results
-
P. Mozzo, C. Procacci, A. Taccoci, P.T. Martini, and I.A. Andreis A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results Eur Radiol 8 1998 1558 1564
-
(1998)
Eur Radiol
, vol.8
, pp. 1558-1564
-
-
Mozzo, P.1
Procacci, C.2
Taccoci, A.3
Martini, P.T.4
Andreis, I.A.5
-
9
-
-
34547935381
-
Endodontic applications of cone-beam volumetric tomography
-
T.P. Cotton, T.M. Geisler, D.T. Holden, S.A. Schwartz, and W.G. Schindler Endodontic applications of cone-beam volumetric tomography J Endod 33 2007 1121 1132
-
(2007)
J Endod
, vol.33
, pp. 1121-1132
-
-
Cotton, T.P.1
Geisler, T.M.2
Holden, D.T.3
Schwartz, S.A.4
Schindler, W.G.5
-
10
-
-
33644639722
-
Clinical applications of cone-beam computed tomograghy in dental practice
-
W.C. Scarfe, A.G. Farman, and P. Sukovic Clinical applications of cone-beam computed tomograghy in dental practice J Can Dent Ass 72 2007 75 80
-
(2007)
J Can Dent Ass
, vol.72
, pp. 75-80
-
-
Scarfe, W.C.1
Farman, A.G.2
Sukovic, P.3
-
11
-
-
39149140366
-
Accuracy of cone beam computed tomography and panoramic and periapical radiography for detection of apical periodontitis
-
C. Estrela, M.R. Bueno, C.R. Leles, B. Azevedo, and J.R. Azevedo Accuracy of cone beam computed tomography and panoramic and periapical radiography for detection of apical periodontitis J Endod 34 2008 273 279
-
(2008)
J Endod
, vol.34
, pp. 273-279
-
-
Estrela, C.1
Bueno, M.R.2
Leles, C.R.3
Azevedo, B.4
Azevedo, J.R.5
-
12
-
-
53349177781
-
A new periapical index based on cone beam computed tomography
-
C. Estrela, M.R. Bueno, B.C. Azevedo, J.R. Azevedo, and J.D. Pécora A new periapical index based on cone beam computed tomography J Endod 34 2008 1325 1333
-
(2008)
J Endod
, vol.34
, pp. 1325-1333
-
-
Estrela, C.1
Bueno, M.R.2
Azevedo, B.C.3
Azevedo, J.R.4
Pécora, J.D.5
-
13
-
-
70349972240
-
Method to evaluate inflammatory root resorption by using cone beam computed tomography
-
C. Estrela, M.R. Bueno, and A.H. Alencar Method to evaluate inflammatory root resorption by using cone beam computed tomography J Endod 35 2009 1491 1497
-
(2009)
J Endod
, vol.35
, pp. 1491-1497
-
-
Estrela, C.1
Bueno, M.R.2
Alencar, A.H.3
-
15
-
-
36148937224
-
Effects of image artifacts on gray-value density in limited-volume cone-beam computerized tomography
-
A. Katsumata, A. Hirukawa, and S. Okumura Effects of image artifacts on gray-value density in limited-volume cone-beam computerized tomography Oral Surg Oral Med Oral Pathol Oral Radiol Endod 104 2007 829 836
-
(2007)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.104
, pp. 829-836
-
-
Katsumata, A.1
Hirukawa, A.2
Okumura, S.3
-
16
-
-
59649097468
-
Relationship between density variability and imaging volume size in cone-beam computerized tomography scanning of the maxillofacial region: An in vitro study
-
A. Katsumata, A. Hirukawa, and S. Okumura Relationship between density variability and imaging volume size in cone-beam computerized tomography scanning of the maxillofacial region: an in vitro study Oral Surg Oral Med Oral Pathol Oral Radiol Endod 107 2009 420 425
-
(2009)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.107
, pp. 420-425
-
-
Katsumata, A.1
Hirukawa, A.2
Okumura, S.3
-
17
-
-
0019362811
-
The environmental density artifact: A beam-hardening effect in computed tomography
-
S.P. Rao, and R.J. Alfidi The environmental density artifact: a beam-hardening effect in computed tomography Radiology 141 1981 223 227
-
(1981)
Radiology
, vol.141
, pp. 223-227
-
-
Rao, S.P.1
Alfidi, R.J.2
-
18
-
-
62649163779
-
Evaluation of high-resolution cone beam computed tomography in the detection of simulated interradicular bone lesions
-
M. Noujeim, T.J. Prihoda, R. Langlais, and P. Nummikoski Evaluation of high-resolution cone beam computed tomography in the detection of simulated interradicular bone lesions Dentomaxillofacial Radiology 38 2009 156 162
-
(2009)
Dentomaxillofacial Radiology
, vol.38
, pp. 156-162
-
-
Noujeim, M.1
Prihoda, T.J.2
Langlais, R.3
Nummikoski, P.4
-
19
-
-
19744369868
-
Artifacts in CT: Recognition and avoidance
-
J.F. Barrett, and N. Keat Artifacts in CT: recognition and avoidance Radiographics 24 2004 1679 1691
-
(2004)
Radiographics
, vol.24
, pp. 1679-1691
-
-
Barrett, J.F.1
Keat, N.2
-
20
-
-
0018177738
-
Polychromatic streak artifacts in computed tomography images
-
A.J. Duerinckx, and A. Macovski Polychromatic streak artifacts in computed tomography images J Comput Assist Tomogr 2 1978 481 487
-
(1978)
J Comput Assist Tomogr
, vol.2
, pp. 481-487
-
-
Duerinckx, A.J.1
MacOvski, A.2
-
21
-
-
0017810277
-
Method for correcting bone induced artifacts in computed tomography scanners
-
P.M. Joseph, and R.D. Spital Method for correcting bone induced artifacts in computed tomography scanners J Comput Assist Tomogr 2 1978 100 108
-
(1978)
J Comput Assist Tomogr
, vol.2
, pp. 100-108
-
-
Joseph, P.M.1
Spital, R.D.2
-
24
-
-
78650178220
-
Influence of the beam hardness on artifacts in cone-beam CT
-
B. Azevedo, R. Lee, W. Shintaku, M. Noujeim, and P. Nummikoski Influence of the beam hardness on artifacts in cone-beam CT Oral Surg Oral Med Oral Pathol Oral Radiol Endod 105 2008 e48
-
(2008)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.105
, pp. 48
-
-
Azevedo, B.1
Lee, R.2
Shintaku, W.3
Noujeim, M.4
Nummikoski, P.5
-
25
-
-
0035342209
-
Acquisition, optimization and interpretation of X-ray computed tomography imagery: Applications to the geosciences
-
A. Ketcham, and W.D. Carlson Acquisition, optimization and interpretation of X-ray computed tomography imagery: applications to the geosciences Computers & Geosciences 27 2001 381 400
-
(2001)
Computers & Geosciences
, vol.27
, pp. 381-400
-
-
Ketcham, A.1
Carlson, W.D.2
-
28
-
-
70350225708
-
Beam hardening artifacts in micro-computed tomography scanning can be reduced by X-ray beam filtration and the resulting images can be used to accurately measure BMD
-
J.A. Meganck, K.M. Kozloff, M.M. Thornton, S.M. Broski, and S.A. Goldstein Beam hardening artifacts in micro-computed tomography scanning can be reduced by X-ray beam filtration and the resulting images can be used to accurately measure BMD Bone 45 2009 1104 1116
-
(2009)
Bone
, vol.45
, pp. 1104-1116
-
-
Meganck, J.A.1
Kozloff, K.M.2
Thornton, M.M.3
Broski, S.M.4
Goldstein, S.A.5
-
29
-
-
40449097647
-
Contemporary management of lateral root perforation diagnosed with the aid of dental computed tomography
-
G.R. Young Contemporary management of lateral root perforation diagnosed with the aid of dental computed tomography Aust Endod J 33 2007 112 118
-
(2007)
Aust Endod J
, vol.33
, pp. 112-118
-
-
Young, G.R.1
|