메뉴 건너뛰기




Volumn 37, Issue 12, 2010, Pages 6221-6232

Joint correction of respiratory motion artifact and partial volume effect in lung/thoracic PET/CT imaging

Author keywords

joint correction; partial volume effect; PET CT; quantification; respiratory motion

Indexed keywords

BIOLOGICAL ORGANS; COMPUTERIZED TOMOGRAPHY; IMAGE ENHANCEMENT; PHANTOMS; POSITRON EMISSION TOMOGRAPHY; RESPIRATORY MECHANICS;

EID: 78650144225     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3512780     Document Type: Article
Times cited : (32)

References (28)
  • 2
    • 1442309461 scopus 로고    scopus 로고
    • Respiratory Artefact Causing Malpositioning of Liver Dome Lesion in Right Lower Lung
    • DOI 10.1097/01.rlu.0000093095.28642.2b
    • I. Sarikaya, H. W. Yeung, Y. Erdi, and S. M. Larson, " Respiratory artefact causing malpositioning of liver dome lesion in right lower lung.," Clin. Nucl. Med. ZZZZZZ 0363-9762 28, 943-944 (2003). 10.1097/01.rlu. 0000093095.28642.2b (Pubitemid 38281864)
    • (2003) Clinical Nuclear Medicine , vol.28 , Issue.11 , pp. 943-944
    • Sarikaya, I.1    Yeung, H.W.D.2    Erdi, Y.3    Larson, S.M.4
  • 3
    • 0031955835 scopus 로고    scopus 로고
    • Correction for partial volume effects in PET: Principles and validation
    • JNMEAQ 0161-5505.
    • O. G. Rousset, Y. Ma, and A. C. Evans, " Correction for partial volume effects in PET: Principles and validation.," J. Nucl. Med. JNMEAQ 0161-5505 39, 904-911 (1998).
    • (1998) J. Nucl. Med. , vol.39 , pp. 904-911
    • Rousset, O.G.1    Ma, Y.2    Evans, A.C.3
  • 4
    • 39049084957 scopus 로고    scopus 로고
    • Factors affecting quantification in PET/CT imaging
    • DOI 10.2174/157340508783502778
    • O. R. Mawlawi, S. C. Kappadath, T. Pan, E. Rohren, and H. A. Macapinlac, " Factors affecting quantification in PET/CT Imaging.," Current Med. Imag. Rev. 1573-4056 4 (1), 34-45 (2008). 10.2174/157340508783502778 (Pubitemid 351234609)
    • (2008) Current Medical Imaging Reviews , vol.4 , Issue.1 , pp. 34-45
    • Mawlawi, O.1    Kappadath, S.C.2    Pan, T.3    Rohren, E.4    Macapinlac, H.A.5
  • 5
    • 34250315240 scopus 로고    scopus 로고
    • Partial-volume effect in PET tumor imaging
    • DOI 10.2967/jnumed.106.035774
    • M. Soret, S. L. Bacharach, and I. Buvat, " Partial-volume effect in PET tumor imaging.," J. Nucl. Med. JNMEAQ 0161-5505 48, 932-945 (2007). 10.2967/jnumed.106.035774 (Pubitemid 46909922)
    • (2007) Journal of Nuclear Medicine , vol.48 , Issue.6 , pp. 932-945
    • Soret, M.1    Bacharach, S.L.2    Buvat, I.3
  • 6
    • 33745649607 scopus 로고    scopus 로고
    • Reducing respiratory motion artifacts in positron emission tomography through retrospective stacking
    • DOI 10.1118/1.2207367
    • B. Thorndyke, E. Schreibmann, A. Koong, and L. Xing, " Reducing respiratory motion artifacts in positron emission tomography through retrospective stacking.," Med. Phys. MPHYA6 0094-2405 33, 2632-2641 (2006). 10.1118/1.2207367 (Pubitemid 43967252)
    • (2006) Medical Physics , vol.33 , Issue.7 , pp. 2632-2641
    • Thorndyke, B.1    Schreibmann, E.2    Koong, A.3    Xing, L.4
  • 7
    • 1542399631 scopus 로고    scopus 로고
    • Respiratory gating for 3-dimensional PET of the thorax: Feasibility and initial results
    • JNMEAQ 0161-5505 ().
    • L. Boucher, S. Rodrigue, R. Lecomte, and F. Benard, " Respiratory gating for 3-dimensional PET of the thorax: Feasibility and initial results.," J. Nucl. Med. JNMEAQ 0161-5505 45 (2), 214-219 (2004).
    • (2004) J. Nucl. Med. , vol.45 , Issue.2 , pp. 214-219
    • Boucher, L.1    Rodrigue, S.2    Lecomte, R.3    Benard, F.4
  • 8
    • 33646440883 scopus 로고    scopus 로고
    • Model-based image reconstruction for four-dimensional PET
    • MPHYA6 0094-2405 (). 10.1118/1.2192581
    • T. Li, B. Thorndyke, E. Schreibmann, Y. Yang, and L. Xing, " Model-based image reconstruction for four-dimensional PET.," Med. Phys. MPHYA6 0094-2405 33 (5), 1288-1298 (2006). 10.1118/1.2192581
    • (2006) Med. Phys. , vol.33 , Issue.5 , pp. 1288-1298
    • Li, T.1    Thorndyke, B.2    Schreibmann, E.3    Yang, Y.4    Xing, L.5
  • 9
    • 33746512521 scopus 로고    scopus 로고
    • A motion-incorporated reconstruction method for gated PET studies
    • DOI 10.1088/0031-9155/51/15/012, PII S0031915506183074, 012
    • F. Qiao, T. Pan, J. W. Clark, and O. R. Mawlawi, " A motion-incorporated reconstruction method for gated PET studies.," Phys. Med. Biol. PHMBA7 0031-9155 51, 3769-3783 (2006). 10.1088/0031-9155/51/15/012 (Pubitemid 44131364)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.15 , pp. 3769-3783
    • Qiao, F.1    Pan, T.2    Clark Jr., J.W.3    Mawlawi, O.R.4
  • 12
    • 75149114655 scopus 로고    scopus 로고
    • Implementation of an automated respiratory amplitude gating technique for PET/CT imaging: Clinical evaluation
    • JNMEAQ 0161-5505 (). 10.2967/jnumed.109.068759
    • G. Chang, T. Chang, T. Pan, J. W. Clark, and O. R. Mawlawi, " Implementation of an automated respiratory amplitude gating technique for PET/CT imaging: Clinical evaluation.," J. Nucl. Med. JNMEAQ 0161-5505 51 (1), 16-24 (2010). 10.2967/jnumed.109.068759
    • (2010) J. Nucl. Med. , vol.51 , Issue.1 , pp. 16-24
    • Chang, G.1    Chang, T.2    Pan, T.3    Clark, J.W.4    Mawlawi, O.R.5
  • 13
    • 0033754806 scopus 로고    scopus 로고
    • Lung cancer proliferation correlates with [F-18]fluorodeoxyglucose uptake by positron emission tomography
    • ZZZZZZ 1078-0432.
    • H. Vesselle, R. A. Schmidt, J. M. Pugsle, M. Li, S. G. Kohlmyer, E. Vallieres, and D. E. Wood, " Lung cancer proliferation correlates with [F-18]fluorodeoxyglucose uptake by positron emission tomography.," Clin. Cancer Res. ZZZZZZ 1078-0432 6, 3837-3844 (2000).
    • (2000) Clin. Cancer Res. , vol.6 , pp. 3837-3844
    • Vesselle, H.1    Schmidt, R.A.2    Pugsle, J.M.3    Li, M.4    Kohlmyer, S.G.5    Vallieres, E.6    Wood, D.E.7
  • 14
    • 0036898673 scopus 로고    scopus 로고
    • Correction of partial-volume effect for PET striatal imaging: Fast implementation and study of robustness
    • JNMEAQ 0161-5505.
    • V. Frouin, C. Comtat, A. Reilhac, and M. C. Gregoire, " Correction of partial-volume effect for PET striatal imaging: Fast implementation and study of robustness.," J. Nucl. Med. JNMEAQ 0161-5505 43, 1715-1726 (2002).
    • (2002) J. Nucl. Med. , vol.43 , pp. 1715-1726
    • Frouin, V.1    Comtat, C.2    Reilhac, A.3    Gregoire, M.C.4
  • 15
  • 16
    • 67349149423 scopus 로고    scopus 로고
    • Incorporation of wavelet-based denoising in iterative deconvolution for partial volume correction in whole-body PET imaging
    • EJNMA6 1619-7070. 10.1007/s00259-009-1065-5
    • N. Boussion, C. Cheze Le Rest, M. Hatt, and D. Visvikis, " Incorporation of wavelet-based denoising in iterative deconvolution for partial volume correction in whole-body PET imaging.," Eur. J. Nucl. Med. Mol. Imaging EJNMA6 1619-7070 36, 1064-1075 (2009). 10.1007/s00259-009-1065-5
    • (2009) Eur. J. Nucl. Med. Mol. Imaging , vol.36 , pp. 1064-1075
    • Boussion, N.1    Cheze Le Rest, C.2    Hatt, M.3    Visvikis, D.4
  • 17
    • 0027465146 scopus 로고
    • Methods for improving quantitation of putamen uptake constant of FDOPA in PET studies
    • JNMEAQ 0161-5505.
    • D. C. Yu, S. C. Huang, S. T. Grafton, W. P. Melega, J. R. Barrio, J. C. Mazziotta, and M. E. Phelps, " Methods for improving quantitation of putamen uptake constant of FDOPA in PET studies.," J. Nucl. Med. JNMEAQ 0161-5505 34, 679-688 (1993).
    • (1993) J. Nucl. Med. , vol.34 , pp. 679-688
    • Yu, D.C.1    Huang, S.C.2    Grafton, S.T.3    Melega, W.P.4    Barrio, J.R.5    Mazziotta, J.C.6    Phelps, M.E.7
  • 19
    • 0032920128 scopus 로고    scopus 로고
    • Simultaneous recovery of size and radioactivity concentration of small spheroids with PET Data
    • JNMEAQ 0161-5505.
    • C. H. Chen, R. F. Muzic, A. D. Nelson, and L. P. Adler, " Simultaneous recovery of size and radioactivity concentration of small spheroids with PET Data.," J. Nucl. Med. JNMEAQ 0161-5505 40, 118-130 (1999).
    • (1999) J. Nucl. Med. , vol.40 , pp. 118-130
    • Chen, C.H.1    Muzic, R.F.2    Nelson, A.D.3    Adler, L.P.4
  • 20
    • 45849153063 scopus 로고    scopus 로고
    • Combined motion blur and partial volume correction for computer aided diagnosis of pulmonary nodules in PET/CT
    • 1861-6410. 10.1007/s11548-008-0212-y 1861-6410
    • R. Wiemker, T. Paulus, S. Kabus, T. Bulow, I. Apostolova, R. Buchert, and S. Klutmann, " Combined motion blur and partial volume correction for computer aided diagnosis of pulmonary nodules in PET/CT.," Int. J. CARS 1861-6410 3, 105-113 (2008). 10.1007/s11548-008-0212-y 1861-6410
    • (2008) Int. J. CARS , vol.3 , pp. 105-113
    • Wiemker, R.1    Paulus, T.2    Kabus, S.3    Bulow, T.4    Apostolova, I.5    Buchert, R.6    Klutmann, S.7
  • 21
    • 77957958703 scopus 로고    scopus 로고
    • Combined correction of recovery effect and motion blur for SUV quantification of solitary pulmonary nodules in FDG PET/CT
    • ZZZZZZ 0938-7994. 10.1007/s00330-010-1747-1
    • I. Apostolova, " Combined correction of recovery effect and motion blur for SUV quantification of solitary pulmonary nodules in FDG PET/CT.," Eur. Radiol. ZZZZZZ 0938-7994 20, 1868-1877 (2010). 10.1007/s00330-010-1747-1
    • (2010) Eur. Radiol. , vol.20 , pp. 1868-1877
    • Apostolova, I.1
  • 22
    • 85167028049 scopus 로고    scopus 로고
    • Performance evaluation of a combined motion blur and partial volume correction approach
    • JNMEAQ 0161-5505 ().
    • G. Chang, T. Chang, J. W. Clark, and O. R. Mawlawi, " Performance evaluation of a combined motion blur and partial volume correction approach.," J. Nucl. Med. JNMEAQ 0161-5505 51 (2), 255P (2010).
    • (2010) J. Nucl. Med. , vol.51 , Issue.2
    • Chang, G.1    Chang, T.2    Clark, J.W.3    Mawlawi, O.R.4
  • 23
    • 0036454017 scopus 로고    scopus 로고
    • Use of a corrected standardized uptake value based on the lesion size on CT permits accurate characterization of lung nodules on FDG-PET
    • EJNMA6 1619-7070 (). 10.1007/s00259-002-0924-0
    • M. Hickeson, M. Yun, A. Matthies, H. Zhuang, L. E. Adam, L. Lacorte, and A. Alavi, " Use of a corrected standardized uptake value based on the lesion size on CT permits accurate characterization of lung nodules on FDG-PET.," Eur. J. Nucl. Med. Mol. Imaging EJNMA6 1619-7070 29 (12), 1639-1647 (2002). 10.1007/s00259-002-0924-0
    • (2002) Eur. J. Nucl. Med. Mol. Imaging , vol.29 , Issue.12 , pp. 1639-1647
    • Hickeson, M.1    Yun, M.2    Matthies, A.3    Zhuang, H.4    Adam, L.E.5    Lacorte, L.6    Alavi, A.7
  • 24
    • 33749410633 scopus 로고    scopus 로고
    • Deblurring of breathing motion artifacts in thoracic PET images by deconvolution methods
    • DOI 10.1118/1.2336500
    • I. E. Naqa, D. A. Low, J. D. Bradley, M. Vicic, and J. O. Deasy, " Deblurring of breathing motion artifacts in thoracic PET images by deconvolution methods.," Med. Phys. MPHYA6 0094-2405 33 (10), 3587-3600 (2006). 10.1118/1.2336500 (Pubitemid 44505085)
    • (2006) Medical Physics , vol.33 , Issue.10 , pp. 3587-3600
    • El Naqa, I.1    Low, D.A.2    Bradley, J.D.3    Vicic, M.4    Deasy, J.O.5
  • 25
    • 0025434487 scopus 로고
    • Image identification and image restoration based on the expectation-maximization algorithm
    • OPEGAR 0091-3286. 10.1117/12.55612
    • A. K. Katsaggelos and K. T. Lay, " Image identification and image restoration based on the expectation-maximization algorithm.," Opt. Eng. (Bellingham) OPEGAR 0091-3286 29, 436-445 (1990). 10.1117/12.55612
    • (1990) Opt. Eng. (Bellingham) , vol.29 , pp. 436-445
    • Katsaggelos, A.K.1    Lay, K.T.2
  • 26
    • 68249153258 scopus 로고    scopus 로고
    • A practical, automated quality assurance method for measuring spatial resolution in PET
    • JNMEAQ 0161-5505. 10.2967/jnumed.108.060079
    • M. A. Lodge, A. Rahmim, and R. L. Wahl, " A practical, automated quality assurance method for measuring spatial resolution in PET.," J. Nucl. Med. JNMEAQ 0161-5505 50, 1307-1314 (2009). 10.2967/jnumed.108.060079
    • (2009) J. Nucl. Med. , vol.50 , pp. 1307-1314
    • Lodge, M.A.1    Rahmim, A.2    Wahl, R.L.3
  • 27
    • 25644456180 scopus 로고    scopus 로고
    • The application of the sinusoidal model to lung cancer patient respiratory motion
    • DOI 10.1118/1.2001220
    • R. George, S. S. Vedam, T. D. Chung, V. Ramakrishnan, and P. J. Keall, " The application of sinusoidal model to lung cancer patient respiratory motion.," Med. Phys. MPHYA6 0094-2405 32 (9), 2850-2861 (2005). 10.1118/1.2001220 (Pubitemid 41384082)
    • (2005) Medical Physics , vol.32 , Issue.9 , pp. 2850-2861
    • George, R.1    Vedam, S.S.2    Chung, T.D.3    Ramakrishnan, V.4    Keall, P.J.5
  • 28
    • 45849135565 scopus 로고    scopus 로고
    • Performance evaluation of an integrated PET/CT scanner: Discovery STE
    • JNMEAQ 0161-5505.
    • P. E. Kinahan, " Performance evaluation of an integrated PET/CT scanner: Discovery STE.," J. Nucl. Med. JNMEAQ 0161-5505 47, 392P (2006).
    • (2006) J. Nucl. Med. , vol.47
    • Kinahan, P.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.