메뉴 건너뛰기




Volumn 50, Issue 8, 2009, Pages 1307-1314

A practical, automated quality assurance method for measuring spatial resolution in PET

Author keywords

Multicenter trials; PET; Quality assurance; Spatial resolution

Indexed keywords

GERMANIUM; GERMANIUM 68; UNCLASSIFIED DRUG;

EID: 68249153258     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: 10.2967/jnumed.108.060079     Document Type: Article
Times cited : (26)

References (16)
  • 1
    • 52949123173 scopus 로고    scopus 로고
    • The American College of Radiology Imaging Network: Clinical trials of diagnostic imaging and image-guided treatment
    • Hillman BJ, Gatsonis C. The American College of Radiology Imaging Network: clinical trials of diagnostic imaging and image-guided treatment. Semin Oncol. 2008;35:460-469.
    • (2008) Semin Oncol , vol.35 , pp. 460-469
    • Hillman, B.J.1    Gatsonis, C.2
  • 2
    • 68249160437 scopus 로고    scopus 로고
    • Quantification of PET and SPECT biomarkers [abstract]
    • Saffer J. Quantification of PET and SPECT biomarkers [abstract]. Med Phys. 2007;34:2556.
    • (2007) Med Phys , vol.34 , pp. 2556
    • Saffer, J.1
  • 3
    • 0003710941 scopus 로고    scopus 로고
    • National Electrical Manufacturers Association, NEMA Standards Publication NU 2-2001. Rosslyn, VA: National Electrical Manufacturers Association;
    • National Electrical Manufacturers Association. Performance Measurements of Positron Emission Tomographs. NEMA Standards Publication NU 2-2001. Rosslyn, VA: National Electrical Manufacturers Association; 2001.
    • (2001) Performance Measurements of Positron Emission Tomographs
  • 5
    • 34247204476 scopus 로고    scopus 로고
    • NEMA NU 2-2001 performance measurements of an LYSO-based PET/CT system in 2D and 3D acquisition modes
    • Kemp BJ, Kim C, Williams JJ, Ganin A, Lowe VJ. NEMA NU 2-2001 performance measurements of an LYSO-based PET/CT system in 2D and 3D acquisition modes. J Nucl Med. 2006;47:1960-1967.
    • (2006) J Nucl Med , vol.47 , pp. 1960-1967
    • Kemp, B.J.1    Kim, C.2    Williams, J.J.3    Ganin, A.4    Lowe, V.J.5
  • 6
    • 0036464422 scopus 로고    scopus 로고
    • The ECAT HRRT: Performance and first clinical application of the new high resolution research tomograph
    • Wienhard K, Schmand M, Casey ME, et al. The ECAT HRRT: performance and first clinical application of the new high resolution research tomograph. IEEE Trans Nucl Sci. 2002;49:104-110.
    • (2002) IEEE Trans Nucl Sci , vol.49 , pp. 104-110
    • Wienhard, K.1    Schmand, M.2    Casey, M.E.3
  • 8
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging. 1994;13:601-609.
    • (1994) IEEE Trans Med Imaging , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 9
    • 0024610693 scopus 로고
    • Analytic 3D image reconstruction using all detected events
    • Kinahan PE, Rogers JG. Analytic 3D image reconstruction using all detected events. IEEE Trans Nucl Sci. 1989;36:964-968.
    • (1989) IEEE Trans Nucl Sci , vol.36 , pp. 964-968
    • Kinahan, P.E.1    Rogers, J.G.2
  • 10
    • 1342311018 scopus 로고    scopus 로고
    • Prospective multicenter study of axillary nodal staging by positron emission tomography in breast cancer: A report of the staging breast cancer with PET Study Group
    • Wahl RL, Siegel BA, Coleman RE, et al. Prospective multicenter study of axillary nodal staging by positron emission tomography in breast cancer: a report of the staging breast cancer with PET Study Group. J Clin Oncol. 2004;22:277-285.
    • (2004) J Clin Oncol , vol.22 , pp. 277-285
    • Wahl, R.L.1    Siegel, B.A.2    Coleman, R.E.3
  • 12
    • 0017066097 scopus 로고
    • The line spread function and modulation transfer function of a computed tomographic scanner
    • Judy PF. The line spread function and modulation transfer function of a computed tomographic scanner. Med Phys. 1976;3:233-236.
    • (1976) Med Phys , vol.3 , pp. 233-236
    • Judy, P.F.1
  • 13
    • 0020644666 scopus 로고
    • Gamma camera MTFs from edge response function measurements
    • Logan KW, Hickey KA. Gamma camera MTFs from edge response function measurements. Med Phys. 1983;10:361-364.
    • (1983) Med Phys , vol.10 , pp. 361-364
    • Logan, K.W.1    Hickey, K.A.2
  • 15
    • 22544484195 scopus 로고    scopus 로고
    • A dual modality approach to quantitative quality control in emission tomography
    • Thomas MDR, Bailey DL, Livieratos L. A dual modality approach to quantitative quality control in emission tomography. Phys Med Biol. 2005;50:N187-N194.
    • (2005) Phys Med Biol , vol.50
    • Thomas, M.D.R.1    Bailey, D.L.2    Livieratos, L.3
  • 16
    • 0027398350 scopus 로고
    • The convergence of object dependent resolution in maximum likelihood based tomographic image reconstruction
    • Liow J-S, Strother SC. The convergence of object dependent resolution in maximum likelihood based tomographic image reconstruction. Phys Med Biol. 1993;38:55-70.
    • (1993) Phys Med Biol , vol.38 , pp. 55-70
    • Liow, J.-S.1    Strother, S.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.