메뉴 건너뛰기




Volumn 3, Issue 4, 2010, Pages 335-340

Late and very late drug-eluting stent malapposition serial 2-year quantitative IVUS analysis

Author keywords

Drug eluting stent; Late stent malapposition; Volumetric IVUS analysis

Indexed keywords

ACUTE HEART INFARCTION; ADULT; ARTICLE; CARDIAC PATIENT; CLINICAL ARTICLE; DISEASE ASSOCIATION; DRUG ELUTING STENT; ELASTICITY; ENDOPROSTHESIS LOOSENING; FEMALE; FOLLOW UP; HEART DEATH; HEART MUSCLE REVASCULARIZATION; HUMAN; IN-STENT RESTENOSIS; INTRAVASCULAR ULTRASOUND; MALE; NEOVASCULARIZATION (PATHOLOGY); PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; STENT MALAPPOSITION; STENT THROMBOSIS;

EID: 78650116798     PISSN: 19417640     EISSN: 19417632     Source Type: Journal    
DOI: 10.1161/CIRCINTERVENTIONS.109.916502     Document Type: Article
Times cited : (25)

References (14)
  • 2
    • 0038241919 scopus 로고    scopus 로고
    • Regional remodeling as the cause of late stent malapposition
    • Mintz GS, Shah VM, Weissman NJ. Regional remodeling as the cause of late stent malapposition. Circulation. 2003;107:2660-2663. (Pubitemid 36667237)
    • (2003) Circulation , vol.107 , Issue.21 , pp. 2660-2663
    • Mintz, G.S.1    Shah, V.M.2    Weissman, N.J.3
  • 3
    • 0036787737 scopus 로고    scopus 로고
    • Background incidence of late malapposition after bare-metal stent implantation
    • Shah VM, Mintz GS, Apple S, Weissman NJ. Background incidence of late malapposition after bare-metal stent implantation. Circulation. 2002; 106:1753-1755.
    • (2002) Circulation , vol.106 , pp. 1753-1755
    • Shah, V.M.1    Mintz, G.S.2    Apple, S.3    Weissman, N.J.4
  • 5
    • 0023740319 scopus 로고
    • Guidelines for percutaneous transluminal coronary angioplasty. A report of the american college of cardiology/american heart association task force on assessment of diagnostic and therapeutic cardiovascular procedures (Subcommittee on Percutaneous Transluminal Coronary Angioplasty)
    • Ryan TJ, Faxon DP, Gunnar RM, Kennedy JW, King SB III, Loop FD, Peterson KL, Reeves TJ, Williams DO, Winters WL Jr. Guidelines for percutaneous transluminal coronary angioplasty. A report of the American College of Cardiology/American Heart Association Task Force on Assessment of Diagnostic and Therapeutic Cardiovascular Procedures (Subcommittee on Percutaneous Transluminal Coronary Angioplasty). Circulation. 1988;78:486-502.
    • (1988) Circulation , vol.78 , pp. 486-502
    • Ryan, T.J.1    Faxon, D.P.2    Gunnar, R.M.3    Kennedy, J.W.4    King III, S.B.5    Loop, F.D.6    Peterson, K.L.7    Reeves, T.J.8    Williams, D.O.9    Winters Jr., W.L.10
  • 6
    • 19944369733 scopus 로고    scopus 로고
    • Quantitative assessment of angiographic restenosis after sirolimus-eluting stent implantation in native coronary arteries
    • DOI 10.1161/01.CIR.0000150331.14687.4B
    • Popma JJ, Leon MB, Moses JW, Holmes DR Jr, Cox N, Fitzpatrick M, Douglas J, Lambert C, Mooney M, Yakubov S, Kuntz RE; SIRIUS Investigators. Quantitative assessment of angiographic restenosis after sirolimuseluting stent implantation in native coronary arteries. Circulation. 2004;110: 3773-3780. (Pubitemid 40023975)
    • (2004) Circulation , vol.110 , Issue.25 , pp. 3773-3780
    • Popma, J.J.1    Leon, M.B.2    Moses, J.W.3    Holmes Jr., D.R.4    Cox, N.5    Fitzpatrick, M.6    Douglas, J.7    Lambert, C.8    Mooney, M.9    Yakubov, S.10    Kuntz, R.E.11
  • 12
    • 0345526804 scopus 로고    scopus 로고
    • Long-Term Follow-Up of Incomplete Stent Apposition in Patients Who Received Sirolimus-Eluting Stent for De Novo Coronary Lesions: An Intravascular Ultrasound Analysis
    • DOI 10.1161/01.CIR.0000103666.25660.77
    • Degertekin M, Serruys PW, Tanabe K, Lee CH, Sousa JE, Colombo A, Morice MC, Ligthart JM, de Feyter PJ. Long-term follow-up of incomplete stent apposition in patients who received sirolimus-eluting stent for de novo coronary lesions: An intravascular ultrasound analysis. Circulation. 2003;108:2747-2750. (Pubitemid 37498975)
    • (2003) Circulation , vol.108 , Issue.22 , pp. 2747-2750
    • Degertekin, M.1    Serruys, P.W.2    Tanabe, K.3    Lee, C.H.4    Sousa, J.E.5    Colombo, A.6    Morice, M.-C.7    Ligthart, J.M.R.8    De Feyter, P.J.9
  • 13
    • 33644877576 scopus 로고    scopus 로고
    • Peristent remodeling and neointimal suppression 2 years after polymer-based, paclitaxel-eluting stent implantation: Insights from serial intravascular ultrasound analysis in the TAXUS II study
    • DOI 10.1161/CIRCULATIONAHA.105.558601, PII 0000301720051220000011
    • Aoki J, Colombo A, Dudek D, Banning AP, Drzewiecki J, Zmudka K, Schiele F, Russell ME, Koglin J, Serruys PW; TAXUS II Study Group. Peristent remodeling and neointimal suppression 2 years after polymerbased, paclitaxel-eluting stent implantation: Insights from serial intravascular ultrasound analysis in the TAXUS II study. Circulation. 2005; 112:3876-3883. (Pubitemid 43739485)
    • (2005) Circulation , vol.112 , Issue.25 , pp. 3876-3883
    • Aoki, J.1    Colombo, A.2    Dudek, D.3    Banning, A.P.4    Drzewiecki, J.5    Zmudka, K.6    Schiele, F.7    Russell, M.E.8    Koglin, J.9    Serruys, P.W.10


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.