메뉴 건너뛰기




Volumn 348, Issue 16, 2003, Pages 1537-1545

A paclitaxel-eluting stent for the prevention of coronary restenosis

Author keywords

[No Author keywords available]

Indexed keywords

ABCIXIMAB; ACETYLSALICYLIC ACID; CILOSTAZOL; CLOPIDOGREL; HEPARIN; PACLITAXEL; RAPAMYCIN; TICLOPIDINE;

EID: 0037451926     PISSN: 00284793     EISSN: None     Source Type: Journal    
DOI: 10.1056/NEJMoa021007     Document Type: Article
Times cited : (435)

References (28)
  • 1
    • 0037116569 scopus 로고    scopus 로고
    • Coronary in-stent restenosis: Current status and future strategies
    • Lowe HC, Oesterle SN, Khachigian LM. Coronary in-stent restenosis: current status and future strategies. J Am Coll Cardiol 2002; 39:183-93.
    • (2002) J Am Coll Cardiol , vol.39 , pp. 183-193
    • Lowe, H.C.1    Oesterle, S.N.2    Khachigian, L.M.3
  • 2
    • 0029837889 scopus 로고    scopus 로고
    • Patterns and mechanisms of in-stent restenosis: A serial intravascular ultrasound study
    • Hoffmann R, Mintz GS, Dussaillant GR, et al. Patterns and mechanisms of in-stent restenosis: a serial intravascular ultrasound study. Circulation 1996;94:1247-54.
    • (1996) Circulation , vol.94 , pp. 1247-1254
    • Hoffmann, R.1    Mintz, G.S.2    Dussaillant, G.R.3
  • 3
    • 0029022299 scopus 로고
    • Prolonged proliferative response of smooth muscle cells after experimental intravascular stenting
    • Hanke H, Kamenz J, Hassenstein S, et al. Prolonged proliferative response of smooth muscle cells after experimental intravascular stenting. Eur Heart J 1995;16:785-93.
    • (1995) Eur Heart J , vol.16 , pp. 785-793
    • Hanke, H.1    Kamenz, J.2    Hassenstein, S.3
  • 4
    • 0033566761 scopus 로고    scopus 로고
    • Histopathologic comparison of human coronary in-stent and post-balloon angioplasty restenotic tissue
    • Moreno PR, Palacios IF, Leon MN, Rhodes J, Fuster V, Fallon JT. Histopathologic comparison of human coronary in-stent and post-balloon angioplasty restenotic tissue. Am J Cardiol 1999;84:462-6.
    • (1999) Am J Cardiol , vol.84 , pp. 462-466
    • Moreno, P.R.1    Palacios, I.F.2    Leon, M.N.3    Rhodes, J.4    Fuster, V.5    Fallon, J.T.6
  • 5
    • 0035422744 scopus 로고    scopus 로고
    • Extent and distribution of in-stent intimal hyperplasia and edge effect in a non-radiation stent population
    • Weissman NJ, Wilensky RL, Tanguay JF, et al. Extent and distribution of in-stent intimal hyperplasia and edge effect in a non-radiation stent population. Am J Cardiol 2001; 88:248-52.
    • (2001) Am J Cardiol , vol.88 , pp. 248-252
    • Weissman, N.J.1    Wilensky, R.L.2    Tanguay, J.F.3
  • 7
    • 0037030658 scopus 로고    scopus 로고
    • A randomized comparison of a sirolimuseluting stent with a standard stent for coronary revascularization
    • Morice M-C, Serruys PW, Sousa JE, et al. A randomized comparison of a sirolimuseluting stent with a standard stent for coronary revascularization. N Engl J Med 2002;346:1773-80.
    • (2002) N Engl J Med , vol.346 , pp. 1773-1780
    • Morice, M.-C.1    Serruys, P.W.2    Sousa, J.E.3
  • 8
    • 0035940374 scopus 로고    scopus 로고
    • Sustained suppression of neointimal proliferation by sirolimus-eluting stents: One-year angiographic and intravascular ultrasound follow-up
    • Sousa JE, Costa MA, Abizaid AC, et al. Sustained suppression of neointimal proliferation by sirolimus-eluting stents: one-year angiographic and intravascular ultrasound follow-up. Circulation 2001;104:2007-11.
    • (2001) Circulation , vol.104 , pp. 2007-2011
    • Sousa, J.E.1    Costa, M.A.2    Abizaid, A.C.3
  • 9
    • 0035176865 scopus 로고    scopus 로고
    • Coronary restenosis elimination with a sirolimus eluting stent: First European human experience with 6-month angiographic and intravascular ultrasound follow-up
    • Rensing BJ, Vos J, Smits PC, etal. Coronary restenosis elimination with a sirolimus eluting stent: first European human experience with 6-month angiographic and intravascular ultrasound follow-up. Eur Heart J 2001;22:2125-30.
    • (2001) Eur Heart J , vol.22 , pp. 2125-2130
    • Rensing, B.J.1    Vos, J.2    Smits, P.C.3
  • 10
    • 0018387446 scopus 로고
    • Promotion of microtubule assembly in vitro by Taxol
    • Shiff PB, Fant J, Horwitz SB. Promotion of microtubule assembly in vitro by Taxol. Nature 1979;277:665-7.
    • (1979) Nature , vol.277 , pp. 665-667
    • Shiff, P.B.1    Fant, J.2    Horwitz, S.B.3
  • 13
    • 84994521433 scopus 로고
    • Paclitaxel (Taxol)
    • Erratum, N Engl J Med 1995;333:75
    • Rowinsky EK, Donehower RC. Paclitaxel (Taxol). N Engl J Med 1995;332:1004-14. [Erratum, N Engl J Med 1995;333:75.]
    • (1995) N Engl J Med , vol.332 , pp. 1004-1014
    • Rowinsky, E.K.1    Donehower, R.C.2
  • 14
    • 0030840892 scopus 로고    scopus 로고
    • Paclitaxel inhibits arterial smooth muscle cell proliferation and migration in vitro and in vivo using local drug delivery
    • Axel DI, Kunert W, Göggelmann C, et al. Paclitaxel inhibits arterial smooth muscle cell proliferation and migration in vitro and in vivo using local drug delivery. Circulation 1997;96:636-45.
    • (1997) Circulation , vol.96 , pp. 636-645
    • Axel, D.I.1    Kunert, W.2    Göggelmann, C.3
  • 15
    • 14344268774 scopus 로고    scopus 로고
    • Paclitaxel stent coating inhibits neointimal hyperplasia at 4 weeks in a porcine model of coronary restenosis
    • Heldman AW, Cheng L, Jenkins GM, et al. Paclitaxel stent coating inhibits neointimal hyperplasia at 4 weeks in a porcine model of coronary restenosis. Circulation 2001;103:2289-95.
    • (2001) Circulation , vol.103 , pp. 2289-2295
    • Heldman, A.W.1    Cheng, L.2    Jenkins, G.M.3
  • 16
    • 0034081030 scopus 로고    scopus 로고
    • Local paclitaxel delivery for prevention of restenosis: Biological effects and efficacy in vivo
    • Herdeg C, Oberhoff M, Baumbach A, et al. Local paclitaxel delivery for prevention of restenosis: biological effects and efficacy in vivo. J Am Coll Cardiol 2000;35:1969-76.
    • (2000) J Am Coll Cardiol , vol.35 , pp. 1969-1976
    • Herdeg, C.1    Oberhoff, M.2    Baumbach, A.3
  • 17
    • 0028946606 scopus 로고
    • Taxol inhibits neointimal smooth muscle cell accumulation after angioplasty in the rat
    • Sollott SJ, Cheng L, Pauly KK, et al. Taxol inhibits neointimal smooth muscle cell accumulation after angioplasty in the rat. J Clin Invest 1995;95:1869-76.
    • (1995) J Clin Invest , vol.95 , pp. 1869-1876
    • Sollott, S.J.1    Cheng, L.2    Pauly, K.K.3
  • 18
    • 0032730697 scopus 로고    scopus 로고
    • Usefulness of cilostazol versus ticlopidine in coronary artery stenting
    • Yoon Y, Shim WH, Lee DH, et al. Usefulness of cilostazol versus ticlopidine in coronary artery stenting. Am J Cardiol 1999;84:1375-80.
    • (1999) Am J Cardiol , vol.84 , pp. 1375-1380
    • Yoon, Y.1    Shim, W.H.2    Lee, D.H.3
  • 19
    • 0032855354 scopus 로고    scopus 로고
    • Comparison of cilostazol versus ticlopidine therapy after stent implantation
    • Park SW, Lee CW, Kim HS, et al. Comparison of cilostazol versus ticlopidine therapy after stent implantation. Am J Cardiol 1999;84:511-4.
    • (1999) Am J Cardiol , vol.84 , pp. 511-514
    • Park, S.W.1    Lee, C.W.2    Kim, H.S.3
  • 20
    • 0342955606 scopus 로고    scopus 로고
    • Effects of cilostazol on angiographic restenosis after coronary stent placement
    • Park SW, Lee CW, Kim HS, et al. Effects of cilostazol on angiographic restenosis after coronary stent placement. Am J Cardiol 2000;86:499-503.
    • (2000) Am J Cardiol , vol.86 , pp. 499-503
    • Park, S.W.1    Lee, C.W.2    Kim, H.S.3
  • 21
    • 0026592026 scopus 로고
    • The importance of acute luminal diameter in determining restenosis after coronary atherectomy or stenting
    • Kuntz RE, Safian RD, Carrozza JP, Fishman RF, Mansour M, Baim DS. The importance of acute luminal diameter in determining restenosis after coronary atherectomy or stenting. Circulation 1992;86:1827-35.
    • (1992) Circulation , vol.86 , pp. 1827-1835
    • Kuntz, R.E.1    Safian, R.D.2    Carrozza, J.P.3    Fishman, R.F.4    Mansour, M.5    Baim, D.S.6
  • 23
    • 0034142223 scopus 로고    scopus 로고
    • Three-year clinical and angiographic follow-up after intracoronary radiation: Results of a randomized clinical trial
    • Teirstein PS, Massullo V, Jani S, et al. Three-year clinical and angiographic follow-up after intracoronary radiation: results of a randomized clinical trial. Circulation 2000;101:360-5.
    • (2000) Circulation , vol.101 , pp. 360-365
    • Teirstein, P.S.1    Massullo, V.2    Jani, S.3
  • 24
    • 0037173076 scopus 로고    scopus 로고
    • Long-term clinical and angiographic follow-up after coronary stent placement in native coronary arteries
    • Kimura T, Abe K, Shizuta S, et al. Long-term clinical and angiographic follow-up after coronary stent placement in native coronary arteries. Circulation 2002;105:2986-91.
    • (2002) Circulation , vol.105 , pp. 2986-2991
    • Kimura, T.1    Abe, K.2    Shizuta, S.3
  • 25
    • 0034896822 scopus 로고    scopus 로고
    • Long-term follow-up after deferring angioplasty in asymptomatic patients with moderate noncritical in-stent restenosis
    • Lee JH, Lee CW, Park SW, et al. Long-term follow-up after deferring angioplasty in asymptomatic patients with moderate noncritical in-stent restenosis. Clin Cardiol 2001;24:551-5.
    • (2001) Clin Cardiol , vol.24 , pp. 551-555
    • Lee, J.H.1    Lee, C.W.2    Park, S.W.3
  • 26
    • 0030877606 scopus 로고    scopus 로고
    • Late regression of the dilated site after coronary angioplasty: A 5-year quantitative angiographic study
    • Ormiston JA, Stewart FM, Roche AH, Webber BJ, Whitlock RM, Webster MW. Late regression of the dilated site after coronary angioplasty: a 5-year quantitative angiographic study. Circulation 1997;96:468-74.
    • (1997) Circulation , vol.96 , pp. 468-474
    • Ormiston, J.A.1    Stewart, F.M.2    Roche, A.H.3    Webber, B.J.4    Whitlock, R.M.5    Webster, M.W.6
  • 27
    • 0030064391 scopus 로고    scopus 로고
    • Late coronary artery stenosis regression within the Gianturco-Roubin intracoronary stent
    • Hermiller JB, Fry ET, Peters TF, et al. Late coronary artery stenosis regression within the Gianturco-Roubin intracoronary stent. Am J Cardiol 1996;77:247-51.
    • (1996) Am J Cardiol , vol.77 , pp. 247-251
    • Hermiller, J.B.1    Fry, E.T.2    Peters, T.F.3
  • 28
    • 0035943063 scopus 로고    scopus 로고
    • Pathological analysis of local delivery of paclitaxel via a polymer-coated stent
    • Farb A, Heller PF, Shroff S, et al. Pathological analysis of local delivery of paclitaxel via a polymer-coated stent. Circulation 2001;104:473-9.
    • (2001) Circulation , vol.104 , pp. 473-479
    • Farb, A.1    Heller, P.F.2    Shroff, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.