메뉴 건너뛰기




Volumn 114, Issue 48, 2010, Pages 20885-20895

The determination of the location of contact electrification-induced discharge events

Author keywords

[No Author keywords available]

Indexed keywords

CIRCULAR PATHS; CONTACT ELECTRIFICATION; ELECTRICAL DISCHARGES; MULTIPLE ELECTRODES; ORGANIC INSULATORS; REAL TIME; RELATIVE AMPLITUDE; RELATIVE POSITIONS; ROLLING SPHERES; STEEL SPHERES;

EID: 78650097662     PISSN: 19327447     EISSN: 19327455     Source Type: Journal    
DOI: 10.1021/jp107883u     Document Type: Article
Times cited : (13)

References (63)
  • 5
    • 85046386185 scopus 로고
    • Shaw, P. E. Nature 1926, 118, 659-660.
    • (1926) Nature , vol.118 , pp. 659-660
    • Shaw, P.E.1
  • 15
  • 20
    • 34250846535 scopus 로고    scopus 로고
    • Schein, L. B. Science 2007, 316, 1572-1573.
    • (2007) Science , vol.316 , pp. 1572-1573
    • Schein, L.B.1
  • 23
    • 0003746199 scopus 로고
    • Harvey, N. E. Science 1939, 89, 460-461.
    • (1939) Science , vol.89 , pp. 460-461
    • Harvey, N.E.1
  • 28
  • 33
    • 78650127746 scopus 로고    scopus 로고
    • The dielectric strength of an insulating material (or medium) is the maximum electric field strength that it can intrinsically withstand without breaking down. For air at 1 atm of pressure, the dielectric strength is ∼30 kV/cm
    • The dielectric strength of an insulating material (or medium) is the maximum electric field strength that it can intrinsically withstand without breaking down. For air at 1 atm of pressure, the dielectric strength is ∼30 kV/cm.
  • 36
    • 78650091837 scopus 로고
    • The ESD control process is a tool for managing quality
    • Brown, L.; Burns, D. The ESD Control Process is a Tool for Managing Quality. Electron. Packag. Prod. 1990, 50-53.
    • (1990) Electron. Packag. Prod. , pp. 50-53
    • Brown, L.1    Burns, D.2
  • 46
    • 78650104460 scopus 로고    scopus 로고
    • Alternatively, when the sphere charges negative and the surface charges positive, the valleys become plateaus and the peaks point down
    • Alternatively, when the sphere charges negative and the surface charges positive, the valleys become plateaus and the peaks point down.
  • 47
    • 78650123751 scopus 로고    scopus 로고
    • For example, a steel sphere (d = 3.2 mm) rolling on an airplasma - treated poly(styrene) Petri dish makes a circular path with a circumference of 15 cm. A 1.0 cm-wide (0.4 rad) electrode sensed 90-100% of the charge on the sphere for 0.4 rad (∼7%) of the circular path (Zone O). The electrode sensed 10-90% of the charge on the sphere for 1.3 rad (∼20%) of the circular path (Zones B and A); the electrode did not sense charge on the sphere for 4.6 rad (∼73%) of the circular path (Zone F)
    • For example, a steel sphere (d = 3.2 mm) rolling on an airplasma - treated poly(styrene) Petri dish makes a circular path with a circumference of 15 cm. A 1.0 cm-wide (0.4 rad) electrode sensed 90-100% of the charge on the sphere for 0.4 rad (∼7%) of the circular path (Zone O). The electrode sensed 10-90% of the charge on the sphere for 1.3 rad (∼20%) of the circular path (Zones B and A); the electrode did not sense charge on the sphere for 4.6 rad (∼73%) of the circular path (Zone F).
  • 52
    • 78650158540 scopus 로고    scopus 로고
    • The rate of charging, and, therefore, the number of discharges, on untreated PS dishes was too low to obtain statistically significant data
    • The rate of charging, and, therefore, the number of discharges, on untreated PS dishes was too low to obtain statistically significant data.
  • 54
    • 78650101830 scopus 로고    scopus 로고
    • min values are ±10 pC. Overall, the error in determining the total discharge is ca. ±40 pC, and for an average discharge of 1200 pC, this error represents approximately ±5%
    • min values are ±10 pC. Overall, the error in determining the total discharge is ca. ±40 pC, and for an average discharge of 1200 pC, this error represents approximately ±5%.
  • 55
    • 78650166743 scopus 로고    scopus 로고
    • The contributions of the baseline disruption to the total discharge in these examples are negligible
    • The contributions of the baseline disruption to the total discharge in these examples are negligible.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.