메뉴 건너뛰기




Volumn 26, Issue 1, 2011, Pages 41-44

Uncemented Tibial Fixation Total Knee Arthroplasty

Author keywords

Primary knee arthroplasty; Tibial base plate; Uncemented

Indexed keywords

BONE CEMENT; HYDROXYAPATITE; POLYETHYLENE;

EID: 78650033892     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2009.12.008     Document Type: Article
Times cited : (35)

References (9)
  • 1
    • 0024950083 scopus 로고
    • Rationale of the Knee Society clinical rating system
    • Insall J.N., Dorr L.D., Scott R.D., et al. Rationale of the Knee Society clinical rating system. Clin Orthop 1989, 13.
    • (1989) Clin Orthop , pp. 13
    • Insall, J.N.1    Dorr, L.D.2    Scott, R.D.3
  • 2
    • 0024950156 scopus 로고
    • The Knee Society total knee arthroplasty radiographic evaluation and scoring system
    • Ewald F.C. The Knee Society total knee arthroplasty radiographic evaluation and scoring system. Clin Orthop Relat Res 1989, 248:9.
    • (1989) Clin Orthop Relat Res , vol.248 , pp. 9
    • Ewald, F.C.1
  • 3
    • 0035208810 scopus 로고    scopus 로고
    • Low contact stress mobile bearing total knee arthroplasty: results at 5 to 13 years
    • Hartford J.M., Hunt T., Kaufer H. Low contact stress mobile bearing total knee arthroplasty: results at 5 to 13 years. J Arthroplasty 2001, 16:977.
    • (2001) J Arthroplasty , vol.16 , pp. 977
    • Hartford, J.M.1    Hunt, T.2    Kaufer, H.3
  • 4
    • 0035408241 scopus 로고    scopus 로고
    • Ten- to 14-year clinical follow-up of the cementless Natural Knee system
    • Hofmann A.A., Evanich J.D., Ferguson R.P., et al. Ten- to 14-year clinical follow-up of the cementless Natural Knee system. Clin Orthop Relat Res 2001, 85.
    • (2001) Clin Orthop Relat Res , pp. 85
    • Hofmann, A.A.1    Evanich, J.D.2    Ferguson, R.P.3
  • 5
    • 0035407026 scopus 로고    scopus 로고
    • Long-term follow-up of the bone-ingrowth Ortholoc knee system without a metal-backed patella
    • Whiteside L.A. Long-term follow-up of the bone-ingrowth Ortholoc knee system without a metal-backed patella. Clin Orthop 2001, 77.
    • (2001) Clin Orthop , pp. 77
    • Whiteside, L.A.1
  • 6
    • 5344246581 scopus 로고    scopus 로고
    • Uncemented rotating-platform total knee replacement: a five- to twelve-year follow-up study
    • American volume
    • Sorrells R.B., Voorhorst P.E., Murphy J.A., et al. Uncemented rotating-platform total knee replacement: a five- to twelve-year follow-up study. J Bone Joint Surg 2004, 86-A:2156. American volume.
    • (2004) J Bone Joint Surg , pp. 2156
    • Sorrells, R.B.1    Voorhorst, P.E.2    Murphy, J.A.3
  • 7
    • 33644751701 scopus 로고    scopus 로고
    • Tibial fixation without screws in cementless total knee arthroplasty
    • Cooke C., Walter W., Zicat B. Tibial fixation without screws in cementless total knee arthroplasty. J Arthroplasty 2006, 21.
    • (2006) J Arthroplasty , vol.21
    • Cooke, C.1    Walter, W.2    Zicat, B.3
  • 8
    • 78650006155 scopus 로고    scopus 로고
    • National Joint Replacement Registry-Australia
    • page-138/tables-KT20, KT21/figure-KT14
    • National Joint Replacement Registry-Australia 2008, page-138/tables-KT20, KT21/figure-KT14.
    • (2008)
  • 9
    • 23644450950 scopus 로고    scopus 로고
    • Prospective analysis of 1000 patients with hydroxyapatite-coated total knee replacements
    • Cross M.J., Parish E.N. Prospective analysis of 1000 patients with hydroxyapatite-coated total knee replacements. J Bone Joint Surg Br 2005, 87-B:1073.
    • (2005) J Bone Joint Surg Br , pp. 1073
    • Cross, M.J.1    Parish, E.N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.