-
1
-
-
37349035313
-
Late coronary stent thrombosis
-
S. Windecker, and B. Meier Late coronary stent thrombosis Circulation 116 2007 952 965
-
(2007)
Circulation
, vol.116
, pp. 952-965
-
-
Windecker, S.1
Meier, B.2
-
2
-
-
10744229988
-
Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: Should we be cautious?
-
R. Virmani, G. Guagliumi, and A. Farb Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious? Circulation 109 2004 701 705
-
(2004)
Circulation
, vol.109
, pp. 701-705
-
-
Virmani, R.1
Guagliumi, G.2
Farb, A.3
-
3
-
-
4644312963
-
Drug-eluting stents: Caution and concerns for long-term outcome
-
R. Virmani, A. Farb, G. Guagliumi, and F.D. Kolodgie Drug-eluting stents: caution and concerns for long-term outcome Coron Art Dis 15 2004 313 318
-
(2004)
Coron Art Dis
, vol.15
, pp. 313-318
-
-
Virmani, R.1
Farb, A.2
Guagliumi, G.3
Kolodgie, F.D.4
-
4
-
-
29344432871
-
Hypersensitivity cases associated with drug-eluting coronary stents: A review of available cases from the Research on Adverse Drug Events and Reports (RADAR) project
-
J.R. Nebecker, R. Virmani, and C.L. Bennett Hypersensitivity cases associated with drug-eluting coronary stents: a review of available cases from the Research on Adverse Drug Events and Reports (RADAR) project J Am Coll Cardiol 47 2006 175 181
-
(2006)
J Am Coll Cardiol
, vol.47
, pp. 175-181
-
-
Nebecker, J.R.1
Virmani, R.2
Bennett, C.L.3
-
5
-
-
68249122647
-
Correlation of intravascular ultrasound findings with histopathogical analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis
-
S. Cook, E. Ladich, and G. Nakazawa Correlation of intravascular ultrasound findings with histopathogical analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis Circulation 120 2009 391 399
-
(2009)
Circulation
, vol.120
, pp. 391-399
-
-
Cook, S.1
Ladich, E.2
Nakazawa, G.3
-
6
-
-
0034597889
-
Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis
-
R. Köster, D. Vieluf, and M. Kiehn Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis Lancet 356 2000 1895 1897
-
(2000)
Lancet
, vol.356
, pp. 1895-1897
-
-
Köster, R.1
Vieluf, D.2
Kiehn, M.3
-
7
-
-
25644451995
-
The impact of metallic allergy on stent implantation: Metal allergy and recurrence of in-stent restenosis
-
R. Iijima, Y. Ikari, and E. Amiya The impact of metallic allergy on stent implantation: metal allergy and recurrence of in-stent restenosis Int J Cardiol 104 2005 319 325
-
(2005)
Int J Cardiol
, vol.104
, pp. 319-325
-
-
Iijima, R.1
Ikari, Y.2
Amiya, E.3
-
8
-
-
67650673809
-
Drug-eluting stent thrombosis: The Kounis hypersensitivity-associated acute coronary syndrome revisited
-
J.P. Chen, D. Hou, L. Pendyala, J.A. Goudevenos, and N.G. Kounis Drug-eluting stent thrombosis: the Kounis hypersensitivity-associated acute coronary syndrome revisited JACC Cardiovasc Interv 2 2009 583 593
-
(2009)
JACC Cardiovasc Interv
, vol.2
, pp. 583-593
-
-
Chen, J.P.1
Hou, D.2
Pendyala, L.3
Goudevenos, J.A.4
Kounis, N.G.5
-
9
-
-
34247558672
-
Clinical end points in coronary stent trials
-
D.E. Cutlip, S. Windecker, and R. Mehran Clinical end points in coronary stent trials Circulation 115 2007 2344 2351
-
(2007)
Circulation
, vol.115
, pp. 2344-2351
-
-
Cutlip, D.E.1
Windecker, S.2
Mehran, R.3
-
11
-
-
77049102900
-
Metal allergy - A review on exposures, penetration, genetics, prevalence, and clinical implications
-
J. Thyssen, and T. Menné Metal allergy - a review on exposures, penetration, genetics, prevalence, and clinical implications Chem Res Toxicol 23 2010 309 318
-
(2010)
Chem Res Toxicol
, vol.23
, pp. 309-318
-
-
Thyssen, J.1
Menné, T.2
-
12
-
-
77952744608
-
2-year clinical and angiographic outcomes from a randomized trial of polymer-free dual drug-eluting stents versus polymer-based Cypher and Endeavour, drug-eluting stents
-
R.A. Byrne, A. Kastrati, and K. Tiroch 2-year clinical and angiographic outcomes from a randomized trial of polymer-free dual drug-eluting stents versus polymer-based Cypher and Endeavour, drug-eluting stents J Am Coll Cardiol 55 2010 2536 2543
-
(2010)
J Am Coll Cardiol
, vol.55
, pp. 2536-2543
-
-
Byrne, R.A.1
Kastrati, A.2
Tiroch, K.3
-
13
-
-
57549110416
-
Ethical authorship and publishing
-
A.J. Coats Ethical authorship and publishing Int J Cardiol 131 2009 149 150
-
(2009)
Int J Cardiol
, vol.131
, pp. 149-150
-
-
Coats, A.J.1
|