1
-
-
23644458446
-
The customised electronic nebuliser: A new category of liquid aerosol drug delivery systems
-
DOI 10.1517/17425247.2.2.377
-
M Knoch M Keller 2005 The customised electronic nebuliser: a new category of liquid aerosol drug delivery systems Expert Opin Drug Deliv 2 377 390 1:CAS:528:DC%2BD2MXjsFant78%3D 10.1517/17425247.2.2.377 16296761 (Pubitemid 41130890)
-
(2005)
Expert Opinion on Drug Delivery
, vol.2
, Issue.2
, pp. 377-390
-
-
Knoch, M.1
Keller, M.2
-
2
-
-
3042814562
-
Nanosuspensions: A promising drug delivery strategy
-
DOI 10.1211/0022357023691
-
VB Patravale AA Date RM Kulkarni 2004 Nanosuspensions: a promising drug delivery strategy J Pharm Pharmacol 56 827 840 1:CAS:528:DC%2BD2cXmtFGqtL8%3D 10.1211/0022357023691 15233860 (Pubitemid 38885975)
-
(2004)
Journal of Pharmacy and Pharmacology
, vol.56
, Issue.7
, pp. 827-840
-
-
Patravale, V.B.1
Date, A.A.2
Kulkarni, R.M.3
-
3
-
-
0001388749
-
Extrathoracic deposition of inhaled, coarse particles (4.5 μm) in children vs. adults
-
WD Bennet KL Zeman WC Kang MS Schechter 1997 Extrathoracic deposition of inhaled, coarse particles (4.5 μm) in children vs. adults Ann Occup Hyg 41 497 502
-
(1997)
Ann Occup Hyg
, vol.41
, pp. 497-502
-
-
Bennet, W.D.1
Zeman, K.L.2
Kang, W.C.3
Schechter, M.S.4
-
4
-
-
0033061674
-
The conventional ultrasonic nebulizer proved inefficient in nebulizing a suspension
-
1:STN:280:DyaK1MznvVKjtA%3D%3D 10.1089/jam.1999.12.47 10539706
-
K Nikander M Turpeinen P Wollmer 1999 The conventional ultrasonic nebulizer proved inefficient in nebulizing a suspension J Aerosol Med 12 47 53 1:STN:280:DyaK1MznvVKjtA%3D%3D 10.1089/jam.1999.12.47 10539706
-
(1999)
J Aerosol Med
, vol.12
, pp. 47-53
-
-
Nikander, K.1
Turpeinen, M.2
Wollmer, P.3
-
5
-
-
0034614208
-
Microemulsion-based media as novel drug delivery systems
-
1:CAS:528:DC%2BD3cXosFertb4%3D 10.1016/S0169-409X(00)00103-4 11104900
-
MJ Lawrence GD Rees 2000 Microemulsion-based media as novel drug delivery systems Adv Drug Deliv Rev 45 89 121 1:CAS:528:DC%2BD3cXosFertb4%3D 10.1016/S0169-409X(00)00103-4 11104900
-
(2000)
Adv Drug Deliv Rev
, vol.45
, pp. 89-121
-
-
Lawrence, M.J.1
Rees, G.D.2
-
6
-
-
0033430984
-
Microemulsions: An overview and pharmaceutical applications
-
1:CAS:528:DC%2BD3cXjs1SjsA%3D%3D 10635455
-
S Tenjarla 1999 Microemulsions: an overview and pharmaceutical applications Crit Rev Ther Drug Carrier Syst 16 461 521 1:CAS:528: DC%2BD3cXjs1SjsA%3D%3D 10635455
-
(1999)
Crit Rev Ther Drug Carrier Syst
, vol.16
, pp. 461-521
-
-
Tenjarla, S.1
-
7
-
-
0037240752
-
Water-in-fluorocarbon reverse emulsion as a pulmonary drug delivery system: Effect on the lung as modelled by a phospholipid monolayer. S.T.P
-
1:CAS:528:DC%2BD3sXjslSltro%3D
-
H Courrier MP Krafft S Nakamura O Shibata T Vandamme 2003 Water-in-fluorocarbon reverse emulsion as a pulmonary drug delivery system: effect on the lung as modelled by a phospholipid monolayer. S.T.P Pharma Pratiques 13 22 26 1:CAS:528:DC%2BD3sXjslSltro%3D
-
(2003)
Pharma Pratiques
, vol.13
, pp. 22-26
-
-
Courrier, H.1
Krafft, M.P.2
Nakamura, S.3
Shibata, O.4
Vandamme, T.5
-
8
-
-
12244300914
-
Formation of fluorinated nonionic surfactant microemulsions in hydrofluorocarbon 134a (HFC 134a)
-
DOI 10.1016/S0021-9797(02)00072-3
-
N Patel M Marlow MJ Lawrence 2003 Formation of non-ionic fluorinated surfactant microemulsions in hydrofluorocarbon 134a (HFC 134a) J Colloid Interface Sci 258 345 353 1:CAS:528:DC%2BD3sXhsFOns7w%3D 10.1016/S0021-9797(02) 00072-3 12618104 (Pubitemid 36293366)
-
(2003)
Journal of Colloid and Interface Science
, vol.258
, Issue.2
, pp. 345-353
-
-
Patel, N.1
Marlow, M.2
Lawrence, M.J.3
-
9
-
-
12244297092
-
Fluorinated ionic surfactant microemulsions in hydrofluorocarbon 134a (HFC 134a)
-
DOI 10.1016/S0021-9797(02)00071-1
-
N Patel M Marlow MJ Lawrence 2003 Fluorinated ionic surfactant microemulsions in hydrofluorocarbon 134a (HFC 134a) J Colloid Interface Sci 258 354 362 1:CAS:528:DC%2BD3sXhsFOns7o%3D 10.1016/S0021-9797(02)00071-1 12618105 (Pubitemid 36293367)
-
(2003)
Journal of Colloid and Interface Science
, vol.258
, Issue.2
, pp. 354-362
-
-
Patel, N.1
Marlow, M.2
Lawrence, M.J.3
-
10
-
-
23144449960
-
Aerosol generation by metered-dose inhalers containing dimethyl ether/propane inverse microemulsions
-
10.1208/pt040458
-
ML Sommerville AJ Hickey 2003 Aerosol generation by metered-dose inhalers containing dimethyl ether/propane inverse microemulsions AAPS PharmSciTech 4 455 461 10.1208/pt040458
-
(2003)
AAPS PharmSciTech
, vol.4
, pp. 455-461
-
-
Sommerville, M.L.1
Hickey, A.J.2
-
11
-
-
0036359928
-
Lecithin microemulsions in dimethyl ether and propane for the generation of pharmaceutical aerosols containing polar solutes
-
DOI 10.1081/PDT-120005724
-
ML Sommerville CS Johnson JB Cain F Rypacek AJ Hickey 2002 Lecithin microemulsions in dimethyl ether and propane for the generation of pharmaceutical aerosols containing polar solutes Pharm Dev Technol 7 273 288 1:CAS:528:DC%2BD38XmvFOns70%3D 10.1081/PDT-120005724 12229259 (Pubitemid 34983119)
-
(2002)
Pharmaceutical Development and Technology
, vol.7
, Issue.3
, pp. 273-288
-
-
Sommerville, M.L.1
Johnson, C.S.2
Cain, J.B.3
Rypacek, F.4
Hickey, A.J.5
-
12
-
-
48849091581
-
Determination of factors controlling the particle size in nanoemulsions using artificial neural networks
-
1:CAS:528:DC%2BD1cXpvF2qs74%3D 10.1016/j.ejps.2008.06.002 18617002
-
A Amani P York H Chrystyn BJ Clark DQ Do 2008 Determination of factors controlling the particle size in nanoemulsions using artificial neural networks Eur J Pharm Sci 35 42 51 1:CAS:528:DC%2BD1cXpvF2qs74%3D 10.1016/j.ejps.2008.06. 002 18617002
-
(2008)
Eur J Pharm Sci
, vol.35
, pp. 42-51
-
-
Amani, A.1
York, P.2
Chrystyn, H.3
Clark, B.J.4
Do, D.Q.5
-
13
-
-
11844261468
-
In vitro comparison of nebulised budesonide (Pulmicort Respules®) and beclomethasone dipropionate (Clenil® per Aerosol)
-
DOI 10.1016/j.pupt.2004.10.004, PII S1094553904001348
-
A Vaghi E Berg S Liljedahl JO Scensson 2005 In vitro comparison of nebulised budesonide (Pulmicort Respules®) and beclomethasone dipropionate (Clenil® per Aerosol) Pulm Pharmacol 18 151 153 1:CAS:528: DC%2BD2MXis1Sktw%3D%3D 10.1016/j.pupt.2004.10.004 (Pubitemid 40092666)
-
(2005)
Pulmonary Pharmacology and Therapeutics
, vol.18
, Issue.2
, pp. 151-153
-
-
Vaghi, A.1
Berg, E.2
Liljedahl, S.3
Svensson, J.O.4
-
15
-
-
0036360175
-
An investigation of in vitro/in vivo correlation for salbutamol nebulized by eight systems
-
1:CAS:528:DC%2BD38XnsVSlt7Y%3D 10.1089/089426802760292591 12396413
-
VL Silkstone JH Dennis CA Pieron H Chrystyn 2002 An investigation of in vitro/in vivo correlation for salbutamol nebulized by eight systems J Aerosol Med 15 251 259 1:CAS:528:DC%2BD38XnsVSlt7Y%3D 10.1089/089426802760292591 12396413
-
(2002)
J Aerosol Med
, vol.15
, pp. 251-259
-
-
Silkstone, V.L.1
Dennis, J.H.2
Pieron, C.A.3
Chrystyn, H.4
-
16
-
-
78649903805
-
High performance liquid chromatography assay method for simultaneous quantitation of formoterol and the two epimers of budesonide
-
M Almeziny BJ Clark 2007 High performance liquid chromatography assay method for simultaneous quantitation of formoterol and the two epimers of budesonide J Pharm Pharmacol 59 Suppl. 1 76
-
(2007)
J Pharm Pharmacol
, vol.59
, Issue.SUPPL. 1
, pp. 76
-
-
Almeziny, M.1
Clark, B.J.2
-
17
-
-
73449096131
-
In vitro delivery of budesonide from 30 jet nebulizer/compressor combinations using infant and child breathing patterns
-
19961633
-
EB Berg RJ Picard 2009 In vitro delivery of budesonide from 30 jet nebulizer/compressor combinations using infant and child breathing patterns Respir Care 54 1671 1678 19961633
-
(2009)
Respir Care
, vol.54
, pp. 1671-1678
-
-
Berg, E.B.1
Picard, R.J.2
-
18
-
-
75749156655
-
Evaluation of supercritical fluid engineered budesonide powder for respiratory delivery using nebulisers
-
1:CAS:528:DC%2BC3cXitFGqsrs%3D 10.1211/jpp.61.12.0006 19958584
-
A Amani H Chrystyn BJ Clark ME Abdelrahim P York 2009 Evaluation of supercritical fluid engineered budesonide powder for respiratory delivery using nebulisers J Pharm Pharmacol 61 1625 1630 1:CAS:528:DC%2BC3cXitFGqsrs%3D 10.1211/jpp.61.12.0006 19958584
-
(2009)
J Pharm Pharmacol
, vol.61
, pp. 1625-1630
-
-
Amani, A.1
Chrystyn, H.2
Clark, B.J.3
Abdelrahim, M.E.4
York, P.5
-
19
-
-
0030988266
-
Selecting and using nebuliser equipment
-
10.1136/thx.52.2008.S92 9155861
-
AH Kendrick EC Smith RS Wilson 1997 Selecting and using nebuliser equipment Thorax 52 2 S92 S101 10.1136/thx.52.2008.S92 9155861
-
(1997)
Thorax
, vol.52
, Issue.2
-
-
Kendrick, A.H.1
Smith, E.C.2
Wilson, R.S.3
-
22
-
-
0028318831
-
Effect of tidal volume on the output and particle size distribution of hypertonic saline from an ultrasonic nebulizer
-
1:STN:280:DyaK2czis12isA%3D%3D 8050559
-
J Riedler CF Robertson 1994 Effect of tidal volume on the output and particle size distribution of hypertonic saline from an ultrasonic nebulizer Eur Respir J 7 998 1002 1:STN:280:DyaK2czis12isA%3D%3D 8050559
-
(1994)
Eur Respir J
, vol.7
, pp. 998-1002
-
-
Riedler, J.1
Robertson, C.F.2
-
23
-
-
65349131457
-
Aerodynamic characteristics of nebulised terbutaline sulphate using the next generation impactor (NGI) and CEN method
-
M Abdelrahim H Chrsytyn 2008 Aerodynamic characteristics of nebulised terbutaline sulphate using the next generation impactor (NGI) and CEN method J Aerosol Med Pulm Drug Deliv 22 19 28
-
(2008)
J Aerosol Med Pulm Drug Deliv
, vol.22
, pp. 19-28
-
-
Abdelrahim, M.1
Chrsytyn, H.2
|