메뉴 건너뛰기




Volumn , Issue , 2010, Pages

Detection of minor winding deformation fault in high frequency range for power transformer

Author keywords

Distortion fault; Frequency response analysis; Transformer winding

Indexed keywords

DISTORTION FAULT; DISTRIBUTED-PARAMETER MODEL; FAULT ANALYSIS; FREQUENCY RANGES; FREQUENCY RESPONSE ANALYSIS; HIGH FREQUENCY; QUANTITATIVE ANALYSIS; SIMULATION DATA; STATISTICAL INDICATORS; WINDING DEFORMATIONS;

EID: 78649567026     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PES.2010.5589573     Document Type: Conference Paper
Times cited : (30)

References (14)
  • 1
    • 0018038144 scopus 로고
    • Transformer diagnostic testing by frequency response analysis
    • November-December
    • E.P. Dick and C.C Erven, Transformer diagnostic testing by frequency response analysis, IEEE Trans. on Power Apparatus and Systems, PAS-97, Vol. 6, pp.2144-2150, November-December, 1978.
    • (1978) IEEE Trans. on Power Apparatus and Systems, PAS-97 , vol.6 , pp. 2144-2150
    • Dick, E.P.1    Erven, C.C.2
  • 2
    • 0037396221 scopus 로고    scopus 로고
    • Transfer function method to diagnose axial displacement and radial deformation of transformer windings
    • E. Rahimpour, J. Christian, K. Feser and H. Mohseni, Transfer function method to diagnose axial displacement and radial deformation of transformer windings, IEEE Transactions on Power Delivery, Vol. 18, No. 2, pp.493-505, 2003.
    • (2003) IEEE Transactions on Power Delivery , vol.18 , Issue.2 , pp. 493-505
    • Rahimpour, E.1    Christian, J.2    Feser, K.3    Mohseni, H.4
  • 5
    • 23944492606 scopus 로고    scopus 로고
    • Improved detection of power transformer winding movement by extending the FRA high frequency range
    • M. Wang, A. Vandermaar, and K.D. Srivastava, Improved detection of power transformer winding movement by extending the FRA high frequency range, IEEE Trans. On Power Delivery, Vol. 20, No. 3, pp.1930-1938, 2005.
    • (2005) IEEE Trans. On Power Delivery , vol.20 , Issue.3 , pp. 1930-1938
    • Wang, M.1    Vandermaar, A.2    Srivastava, K.D.3
  • 6
    • 67349286978 scopus 로고    scopus 로고
    • A novel hybrid winding model of disc-type power transformers for frequency response analysis
    • April
    • A. Shintemirov, W.H. Tang and Q.H. Wu, A novel hybrid winding model of disc-type power transformers for frequency response analysis, IEEE Transactions on Power Delivery, Vol. 24, No. 2, pp.730-739, April 2009.
    • (2009) IEEE Transactions on Power Delivery , vol.24 , Issue.2 , pp. 730-739
    • Shintemirov, A.1    Tang, W.H.2    Wu, Q.H.3
  • 7
    • 0024626321 scopus 로고
    • A computer model for calculating steep-front surge distribution in mashine windings
    • March
    • J.L. Guardado and K.J. Cornick, A computer model for calculating steep-front surge distribution in mashine windings, IEEE Trans. Energy Convers., Vol. 4, No. 1, pp.95C101, March 1989.
    • (1989) IEEE Trans. Energy Convers. , vol.4 , Issue.1
    • Guardado, J.L.1    Cornick, K.J.2
  • 8
    • 0037667689 scopus 로고    scopus 로고
    • Diagnosing transformer faults using frequency responce analysis
    • S. A. Ryder. Diagnosing transformer faults using frequency responce analysis. IEEE Electrical Insulation Magazine, Vol. 19, No. 2, pp.16-22, 2003.
    • (2003) IEEE Electrical Insulation Magazine , vol.19 , Issue.2 , pp. 16-22
    • Ryder, S.A.1
  • 9
    • 77953343319 scopus 로고    scopus 로고
    • Transformer sweep frequency response analysis (SFRA)
    • October
    • G. M. Kennedy, A. J. McGrail, and J. A. Lapworth. Transformer sweep frequency response analysis (SFRA). Energize, (October):28-33, 2007.
    • (2007) Energize , pp. 28-33
    • Kennedy, G.M.1    McGrail, A.J.2    Lapworth, J.A.3
  • 11
    • 33748463297 scopus 로고    scopus 로고
    • Application of articial neural network to the detection of the transformer winding deformation
    • London, August
    • D. K. Xu, C. Z. Fu, and Y. M. Li. Application of articial neural network to the detection of the transformer winding deformation. In Eleventh International Symposium on High Voltage Engineering, 1999, Vol. 5, pp.220-223, London, August 1999.
    • (1999) Eleventh International Symposium on High Voltage Engineering, 1999 , vol.5 , pp. 220-223
    • Xu, D.K.1    Fu, C.Z.2    Li, Y.M.3
  • 12
    • 12544255076 scopus 로고    scopus 로고
    • Fault diagnosis of a power transformer using an improved frequency response analysis
    • J. W. Kim, B. Park, S. C. Jeong, S. W. Kim, and P. Park. Fault diagnosis of a power transformer using an improved frequency response analysis. IEEE Transactions on Power Delivery, Vol. 20, No.1, pp.169-178, 2005.
    • (2005) IEEE Transactions on Power Delivery , vol.20 , Issue.1 , pp. 169-178
    • Kim, J.W.1    Park, B.2    Jeong, S.C.3    Kim, S.W.4    Park, P.5
  • 14
    • 5044247505 scopus 로고    scopus 로고
    • Transformer winding movement monitoring in service - Key factors affecting fra measurements
    • M. Wang, A. J. Vandermaar, and K. D. Srivastava. Transformer winding movement monitoring in service - key factors affecting fra measurements. IEEE Electrical Insulation Magazine, Vol. 20, No.5, pp.5-12, 2004.
    • (2004) IEEE Electrical Insulation Magazine , vol.20 , Issue.5 , pp. 5-12
    • Wang, M.1    Vandermaar, A.J.2    Srivastava, K.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.