메뉴 건너뛰기




Volumn 34, Issue 11, 2010, Pages 1039-1044

Filament support spindle for an intravascular cavopulmonary assist device

Author keywords

Artificial right ventricle; Cavopulmonary assist device; Fontan completion; Heart pump; Intravascular blood pump; Mechanical cavopulmonary assist; Pediatric circulatory support; Single ventricle physiology; Ventricular assist device

Indexed keywords

ARTIFICIAL HEART; BLOOD VESSELS; COMPUTATIONAL FLUID DYNAMICS; LEFT VENTRICULAR ASSIST DEVICES; PUMPS;

EID: 78649557585     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2010.01139.x     Document Type: Article
Times cited : (4)

References (12)
  • 1
    • 55949089133 scopus 로고    scopus 로고
    • Pediatric circulatory support systems: current strategies and future directions. Biventricular and univentricular mechanical assistance
    • Throckmorton AL, Chopski SG. Pediatric circulatory support systems: current strategies and future directions. Biventricular and univentricular mechanical assistance. ASAIO J 2008;54:491-7.
    • (2008) ASAIO J , vol.54 , pp. 491-497
    • Throckmorton, A.L.1    Chopski, S.G.2
  • 2
    • 37349037210 scopus 로고    scopus 로고
    • Long-term survival, modes of death, and predictors of mortality in patients with Fontan surgery
    • Khairy P, Fernandez SM, Mayer JE, et al. Long-term survival, modes of death, and predictors of mortality in patients with Fontan surgery. Circulation 2008;117:85-92.
    • (2008) Circulation , vol.117 , pp. 85-92
    • Khairy, P.1    Fernandez, S.M.2    Mayer, J.E.3
  • 3
    • 17444368111 scopus 로고    scopus 로고
    • Physics-driven CFD modeling of complex anatomical cardiovascular flows-a TCPC case study
    • Pekkan K, De Zélicourt D, Ge L, et-al. Physics-driven CFD modeling of complex anatomical cardiovascular flows-a TCPC case study. Ann Biomed Eng 2005;33:284-300.
    • (2005) Ann Biomed Eng , vol.33 , pp. 284-300
    • Pekkan, K.1    De Zélicourt, D.2    Ge, L.3
  • 4
    • 0029932469 scopus 로고    scopus 로고
    • Use of computational fluid dynamics in the design of surgical procedures: application to the study of competitive flows in the cavopulmonary connections
    • De Leval MR, Dubini G, Migiliavacca F, et-al. Use of computational fluid dynamics in the design of surgical procedures: application to the study of competitive flows in the cavopulmonary connections. J Thorac Cardiovasc Surg 1996;111:502-11.
    • (1996) J Thorac Cardiovasc Surg , vol.111 , pp. 502-511
    • De Leval, M.R.1    Dubini, G.2    Migiliavacca, F.3
  • 5
    • 0030866886 scopus 로고    scopus 로고
    • Fontan operation in five hundred consecutive patients: factors influencing early and late outcome
    • Gentles TL, Mayer JE, Gauvreau K, et-al. Fontan operation in five hundred consecutive patients: factors influencing early and late outcome. J Thorac Cardiovasc Surg 1997;114:376-91.
    • (1997) J Thorac Cardiovasc Surg , vol.114 , pp. 376-391
    • Gentles, T.L.1    Mayer, J.E.2    Gauvreau, K.3
  • 6
    • 70450267398 scopus 로고    scopus 로고
    • Intravascular mechanical cavopulmonary assistance for patients with failing Fontan physiology
    • Bhavsar SS, Kapadia JY, Chopski SG, Throckmorton AL. Intravascular mechanical cavopulmonary assistance for patients with failing Fontan physiology. Artif Organs 2009;33:977-87.
    • (2009) Artif Organs , vol.33 , pp. 977-987
    • Bhavsar, S.S.1    Kapadia, J.Y.2    Chopski, S.G.3    Throckmorton, A.L.4
  • 8
    • 0019186014 scopus 로고
    • A Couette viscometer for short time shearing in blood
    • Heuser G, Opitz R. A Couette viscometer for short time shearing in blood. Biorheology 1980;17:17-24.
    • (1980) Biorheology , vol.17 , pp. 17-24
    • Heuser, G.1    Opitz, R.2
  • 9
    • 36549056164 scopus 로고    scopus 로고
    • Numerical design and experimental hydraulic testing of an axial flow VAD for infants and children
    • Throckmorton AL, Untaroiu A, Allaire PE, et-al. Numerical design and experimental hydraulic testing of an axial flow VAD for infants and children. ASAIO J 2007;53:754-61.
    • (2007) ASAIO J , vol.53 , pp. 754-761
    • Throckmorton, A.L.1    Untaroiu, A.2    Allaire, P.E.3
  • 11
    • 78649571989 scopus 로고    scopus 로고
    • Cavopulmonary assist using a percutaneous, bi-conical, single impeller pump: a new spin for Fontan circulatory support. 89th Annual Meeting of the American Association for Thoracic Surgery, in Boston, MA, USA, May 9-13
    • Rodefeld MD, Coats B, Fisher T, Brown J, Frankel SH. Cavopulmonary assist using a percutaneous, bi-conical, single impeller pump: a new spin for Fontan circulatory support. 89th Annual Meeting of the American Association for Thoracic Surgery, in Boston, MA, USA, May 9-13, 2009.
    • (2009)
    • Rodefeld, M.D.1    Coats, B.2    Fisher, T.3    Brown, J.4    Frankel, S.H.5
  • 12
    • 67649807385 scopus 로고    scopus 로고
    • An artificial right ventricle for failing Fontan: in vitro and computational study
    • Lacour-Gayet FG, Lanning CJ, Stoica S, et-al. An artificial right ventricle for failing Fontan: in vitro and computational study. Ann Thorac Surg 2009;88:170-6.
    • (2009) Ann Thorac Surg , vol.88 , pp. 170-176
    • Lacour-Gayet, F.G.1    Lanning, C.J.2    Stoica, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.