메뉴 건너뛰기




Volumn 99, Issue 6, 2010, Pages 806-810

Thermal response of tissues to millimeter waves: Implications for setting exposure guidelines

Author keywords

exposure; microwaves; radiofrequency; standards

Indexed keywords

ARTICLE; BIOLOGICAL MODEL; BODY TEMPERATURE; HUMAN; INTERNATIONAL COOPERATION; MICROWAVE RADIATION; PRACTICE GUIDELINE; RADIATION EXPOSURE; RADIATION INJURY; RADIATION PROTECTION; RISK ASSESSMENT; STANDARD; TISSUE DISTRIBUTION;

EID: 78649542259     PISSN: 00179078     EISSN: None     Source Type: Journal    
DOI: 10.1097/HP.0b013e3181db29e6     Document Type: Article
Times cited : (8)

References (16)
  • 1
    • 58649098189 scopus 로고    scopus 로고
    • Influence of blood flow and millimeter wave exposure on skin temperature in different thermal models
    • Alekseev SI, Ziskin MC. Influence of blood flow and millimeter wave exposure on skin temperature in different thermal models. Bioelectromagnetics 30:52-58; 2009.
    • (2009) Bioelectromagnetics , vol.30 , pp. 52-58
    • Alekseev, S.I.1    Ziskin, M.C.2
  • 2
    • 78649533131 scopus 로고    scopus 로고
    • ANSI. American National Standard for the safe use of lasers. New York: American National Standards Institute; Z136.1-2000
    • ANSI. American National Standard for the safe use of lasers. New York: American National Standards Institute; Z136.1-2000;2000.
    • (2000)
  • 3
    • 44649184232 scopus 로고    scopus 로고
    • Calculating the optimum temperature for serving hot beverages
    • Brown F, Diller KR. Calculating the optimum temperature for serving hot beverages. Burns 34:648-654; 2008.
    • (2008) Burns , vol.34 , pp. 648-654
    • Brown, F.1    Diller, K.R.2
  • 6
    • 0038103472 scopus 로고    scopus 로고
    • Thermal modeling of millimeter wave damage to the primate cornea at 35 GHz and 94 GHz
    • Foster KR, D'Andrea JA, Chalfin S, Hatcher DJ. Thermal modeling of millimeter wave damage to the primate cornea at 35 GHz and 94 GHz. Health Phys 84:764-769; 2003.
    • (2003) Health Phys. , vol.84 , pp. 764-769
    • Foster, K.R.1    D'Andrea, J.A.2    Chalfin, S.3    Hatcher, D.J.4
  • 7
    • 0029909341 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz
    • DOI 10.1088/0031-9155/41/11/002
    • Gabriel S, Lau SRW, Gabriel C. The dielectric properties of biological tissues. 2. Measurements in the frequency range 10 Hz to 20 GHz. Phys Med Biol 41:2251-2269;1996. (Pubitemid 26376902)
    • (1996) Physics in Medicine and Biology , vol.41 , Issue.11 , pp. 2251-2269
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3
  • 8
    • 0022665435 scopus 로고
    • Absorption of millimeter waves by human beings and its biological implications
    • Gandhi OP, Riazi A. Absorption of millimeter waves by human beings and its biological implications. IEEE Trans Micr Th Tech 34:228-235; 1986.
    • (1986) IEEE Trans Micr Th Tech , vol.34 , pp. 228-235
    • Gandhi, O.P.1    Riazi, A.2
  • 9
    • 84984821750 scopus 로고
    • Studies of thermal injury. 5. The predictability and the significance of thermally induced rate processes leading to irreversible epidermal injury
    • Henriques FC. Studies of thermal injury. 5. The predictability and the significance of thermally induced rate processes leading to irreversible epidermal injury. Arch Path 43:489-502; 1947.
    • (1947) Arch. Path , vol.43 , pp. 489-502
    • Henriques, F.C.1
  • 10
    • 0343375204 scopus 로고    scopus 로고
    • International Commission on Non-Ionizing Radiation Protection. Guidelines for limiting exposure to time-varying electric, magnetic and electromagnetic fields up to 300 GHz
    • International Commission on Non-Ionizing Radiation Protection. Guidelines for limiting exposure to time-varying electric, magnetic and electromagnetic fields (up to 300 GHz). Health Phys 74:494-522; 1998.
    • (1998) Health Phys. , vol.74 , pp. 494-522
  • 11
    • 78649603651 scopus 로고    scopus 로고
    • IEEE. IEEE Standard for safety levels with respect to human exposure to radio frequency electromagnetic fields, 3 kHz to 300 GHz. Piscataway, NJ: Institute of Electrical and Electronic Engineers; C95.1-2005
    • IEEE. IEEE Standard for safety levels with respect to human exposure to radio frequency electromagnetic fields, 3 kHz to 300 GHz. Piscataway, NJ: Institute of Electrical and Electronic Engineers; C95.1-2005;2005.
    • (2005)
  • 12
    • 0008649908 scopus 로고    scopus 로고
    • Safety and environmental issues
    • Golio M, Golio J, eds, Boca Raton, FL: CRC Press;, 21-1-21-21
    • Osepchuk JM, Petersen RC. Safety and environmental issues. In: Golio M, Golio J, eds. The RF and microwave handbook. Boca Raton, FL: CRC Press; 2008:21-1-21-21.
    • (2008) The RF and Microwave Handbook
    • Osepchuk, J.M.1    Petersen, R.C.2
  • 13
    • 38049174740 scopus 로고    scopus 로고
    • Heat analysis of biological tissue exposed to microwave by using thermal wave model of bio-heat transfer
    • Ozen S, Helhel S, Cerezci O. Heat analysis of biological tissue exposed to microwave by using thermal wave model of bio-heat transfer. Burns 34:45-49; 2008.
    • (2008) Burns , vol.34 , pp. 45-49
    • Ozen, S.1    Helhel, S.2    Cerezci, O.3
  • 14
    • 84888360034 scopus 로고
    • Analysis of tissue and arterial blood temperature in resting forearm
    • Pennes HH. Analysis of tissue and arterial blood temperature in resting forearm. J Appl Physiol 1:93-122; 1948.
    • (1948) J. Appl. Physiol. , vol.1 , pp. 93-122
    • Pennes, H.H.1
  • 15
    • 0030627330 scopus 로고    scopus 로고
    • A thermal model for human thresholds of microwave-evoked warmth sensations
    • Riu PJ, Foster KR, Blick DW, Adair ER. A thermal model for human thresholds of microwave-evoked warmth sensations. Bioelectromagnetics 18:578-583; 1997.
    • (1997) Bioelectromagnetics , vol.18 , pp. 578-583
    • Riu, P.J.1    Foster, K.R.2    Blick, D.W.3    Adair, E.R.4
  • 16
    • 0033960576 scopus 로고    scopus 로고
    • Heating and pain sensations produced in human skin by millimeter waves: Validation of a simple thermal model
    • Walters TJ, Blick DW, Johnson LR, Adair ER, Foster KR. Heating and pain sensations produced in human skin by millimeter waves: validation of a simple thermal model. Health Phys 78:259-267; 2000.
    • (2000) Health Phys. , vol.78 , pp. 259-267
    • Walters, T.J.1    Blick, D.W.2    Johnson, L.R.3    Adair, E.R.4    Foster, K.R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.