Volumn 42, Issue 3, 2010, Pages 212-218

Monitoring microemboli during cardiopulmonary bypass with the EDAC® quantifier

Author keywords

Cardiopulmonary bypass; Cerebral protection; Gaseous microemboli; Ultrasound

Indexed keywords

ADULT; AGED; AIR EMBOLISM; ARTICLE; BYPASS SURGERY; CARDIOPULMONARY BYPASS; CLINICAL ARTICLE; CORONARY ARTERY BYPASS GRAFT; DEVICE; DEVICE REMOVAL; FEMALE; HEART VALVE REPLACEMENT; HUMAN; IN VITRO STUDY; INCIDENCE; MALE; MICROEMBOLISM; SENSITIVITY AND SPECIFICITY;

EID: 78649408570     PISSN: 00221058     EISSN: 29698960     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (15)

References (17)
  • 1
    • 0036198227 scopus 로고    scopus 로고
    • The pathophysiology of cerebral arterial gas embolism
    • Mitchell S, Gorman D. The pathophysiology of cerebral arterial gas embolism. J Extra Corpor Technol. 2002;34:18-23. (Pubitemid 34211777)
    • (2002) Journal of Extra-Corporeal Technology , vol.34 , Issue.1 , pp. 18-23
    • Mitchell, S.1    Gorman, D.2
  • 2
    • 2342606061 scopus 로고    scopus 로고
    • Bubbles and bypass: An update
    • Kurusz M, Butler BD. Bubbles and bypass: An update. Perfusion. 2004;19:S49-55.
    • (2004) Perfusion , vol.19
    • Kurusz, M.1    Butler, B.D.2
  • 3
    • 0028223873 scopus 로고
    • Gross air handling characteristics of membrane oxygenators: An in vitro study
    • Courtney PH, Han YQ, Warren ET, Heath BJ. Gross air handling characteristics of membrane oxygenators: An in vitro study. J Extra Corpor Technol. 1994;26:6-12.
    • (1994) J Extra Corpor Technol , vol.26 , pp. 6-12
    • Courtney, P.H.1    Han, Y.Q.2    Warren, E.T.3    Heath, B.J.4
  • 4
    • 11444268980 scopus 로고    scopus 로고
    • The effectiveness of low-prime cardiopulmonary bypass circuits at removing gaseous emboli
    • Norman MJ, Sistino SS, Acsell JR. The effectiveness of low-prime cardiopulmonary bypass circuits at removing gaseous emboli. J Extra Corpor Technol. 2004;36:336-42.
    • (2004) J Extra Corpor Technol , vol.36 , pp. 336-342
    • Norman, M.J.1    Sistino, S.S.2    Acsell, J.R.3
  • 5
    • 0036898954 scopus 로고    scopus 로고
    • Does vacuum-assisted venous drainage increase gaseous microemboli during cardiopulmonary bypass?
    • Jones TJ, Deal DD, Vemon JC, Blackburn N, Stump DA. Does vacuum-assisted venous drainage increase gaseous microemboli during cardiopulmonary bypass? Ann Thorac Surg. 2002;74:2132-7.
    • (2002) Ann Thorac Surg , vol.74 , pp. 2132-2137
    • Jones, T.J.1    Deal, D.D.2    Vemon, J.C.3    Blackburn, N.4    Stump, D.A.5
  • 6
    • 39049184851 scopus 로고    scopus 로고
    • In vitro evaluation of the air separation ability of four cardiovascular manufacturer extracorporeal circuit designs
    • Dickinson TA, Riley JB, Crowley JC, Zabetakis PM. In vitro evaluation of the air separation ability of four cardiovascular manufacturer extracorporeal circuit designs. J Extra Corpor Technol. 2006;38:206-13.
    • (2006) J Extra Corpor Technol , vol.38 , pp. 206-213
    • Dickinson, T.A.1    Riley, J.B.2    Crowley, J.C.3    Zabetakis, P.M.4
  • 8
    • 0031959820 scopus 로고    scopus 로고
    • Brain damage during cardiopulmonary bypass
    • Taylor KM. Brain damage during cardiopulmonary bypass. Ann Thorac Surg. 1998;65:S20-6.
    • (1998) Ann Thorac Surg , vol.65
    • Taylor, K.M.1
  • 9
    • 0032722193 scopus 로고    scopus 로고
    • Venous air in the bypass circuit: A source of arterial line emboli exacerbated by vacuum-assisted drainage
    • Wilcox TW, Mitchell SJ, Gorman DF. Venous air in the bypass circuit: A source of arterial line emboli exacerbated by vacuum-assisted drainage. Ann Thorac Surg. 1999;68:1285-9.
    • (1999) Ann Thorac Surg , vol.68 , pp. 1285-1289
    • Wilcox, T.W.1    Mitchell, S.J.2    Gorman, D.F.3
  • 11
    • 0035323936 scopus 로고    scopus 로고
    • Neuropsychologic impairment after coronary bypass surgery: Effect of gaseous microemboli during perfusionist interventions
    • Borger MA, Peniston CM, Weisel RD, Vasiliou M, Green REA, Feindel CM. Neuropsychologic impairment after coronary bypass surgery: Effect of gaseous microemboli during perfusionist interventions. J Thorac Cardiovasc Surg. 2001;121:743-9.
    • (2001) J Thorac Cardiovasc Surg , vol.121 , pp. 743-749
    • Borger, M.A.1    Peniston, C.M.2    Weisel, R.D.3    Vasiliou, M.4    Green, R.E.A.5    Feindel, C.M.6
  • 12
    • 50649090694 scopus 로고    scopus 로고
    • Microemboli detection on extracorporeal bypass circuits
    • Review
    • Lynch JE, Riley JB. Microemboli detection on extracorporeal bypass circuits. Perfusion. 2008;23:23-32. Review.
    • (2008) Perfusion , vol.23 , pp. 23-32
    • Lynch, J.E.1    Riley, J.B.2
  • 15
  • 16
    • 41949116693 scopus 로고    scopus 로고
    • Arterial line filters ranked for gaseous micro-emboli separation performance: An in-vitro study
    • Riley JB. Arterial line filters ranked for gaseous micro-emboli separation performance: An in-vitro study. J Extra Corpor Technol. 2008;40:21-6.
    • (2008) J Extra Corpor Technol , vol.40 , pp. 21-26
    • Riley, J.B.1
  • 17
    • 64849099938 scopus 로고    scopus 로고
    • Emboli occurrence during coronary artery bypass surgery: The influence of a new method of perfusionist blood sampling
    • Sauren LD, Mooren EJ, Severdija EE, Weerwind PW, Maessen JG. Emboli occurrence during coronary artery bypass surgery: The influence of a new method of perfusionist blood sampling. Perfusion. 2008;23:261-5.
    • (2008) Perfusion , vol.23 , pp. 261-265
    • Sauren, L.D.1    Mooren, E.J.2    Severdija, E.E.3    Weerwind, P.W.4    Maessen, J.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.