메뉴 건너뛰기




Volumn 90, Issue 6, 2010, Pages 2087-2088

Metal allergy, atrial septal occluder devices and the risk of kounis syndrome

Author keywords

[No Author keywords available]

Indexed keywords

ANTIARRHYTHMIC AGENT; ARACHIDONIC ACID; CHEMOKINE; CLOPIDOGREL; CYTOKINE; HISTAMINE; NEUTRAL PROTEINASE; NICKEL; PREDNISONE; THROMBOCYTE ACTIVATING FACTOR;

EID: 78649400082     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.athoracsur.2010.04.076     Document Type: Letter
Times cited : (4)

References (8)
  • 1
    • 71649112723 scopus 로고    scopus 로고
    • Metal allergy to Amplatzer occluder device presented as severe bronchospasm
    • R.A. Khodaverdian, and K.W. Jones Metal allergy to Amplatzer occluder device presented as severe bronchospasm Ann Thorac Surg 88 2009 2021 2022
    • (2009) Ann Thorac Surg , vol.88 , pp. 2021-2022
    • Khodaverdian, R.A.1    Jones, K.W.2
  • 2
    • 77649259509 scopus 로고    scopus 로고
    • Nickel allergy, amplatzer atrial septal occluder device, and the risk of Kounis syndrome
    • G. Almpanis, G. Tsigkas, G. Kounis, and N. Kounis Nickel allergy, amplatzer atrial septal occluder device, and the risk of Kounis syndrome Clin Cardiol 33 2010 117
    • (2010) Clin Cardiol , vol.33 , pp. 117
    • Almpanis, G.1    Tsigkas, G.2    Kounis, G.3    Kounis, N.4
  • 3
    • 36348952103 scopus 로고    scopus 로고
    • Nickel allergy in interatrial shunt devicebased closure patients
    • G. Rigatelli, P. Cardaioli, and M. Giordan Nickel allergy in interatrial shunt devicebased closure patients Congenit Heart Dis 2 2007 416 420
    • (2007) Congenit Heart Dis , vol.2 , pp. 416-420
    • Rigatelli, G.1    Cardaioli, P.2    Giordan, M.3
  • 4
    • 33644926112 scopus 로고    scopus 로고
    • Adverse events associated with nickel allergy in patients undergoing percutaneous atrial septal defect or patent foramen ovale closure
    • B. Wertman, B. Azarbal, M. Riedl, and J. Tobis Adverse events associated with nickel allergy in patients undergoing percutaneous atrial septal defect or patent foramen ovale closure J Am Coll Cardiol 47 2006 1226 1227
    • (2006) J Am Coll Cardiol , vol.47 , pp. 1226-1227
    • Wertman, B.1    Azarbal, B.2    Riedl, M.3    Tobis, J.4
  • 5
    • 33646554451 scopus 로고    scopus 로고
    • Kounis syndrome (Allergic angina and allergic myocatial infarction): A natural paradigm?
    • N.G. Kounis Kounis syndrome (Allergic angina and allergic myocatial infarction): a natural paradigm? Int J Cardiol 110 2006 7 14
    • (2006) Int J Cardiol , vol.110 , pp. 7-14
    • Kounis, N.G.1
  • 6
    • 33746788086 scopus 로고    scopus 로고
    • The most frequent allergens in allergic contact dermatitis
    • T. Oppei, and A. Schnuch The most frequent allergens in allergic contact dermatitis Dtsch Med Wochennschr 131 2006 1584 1589
    • (2006) Dtsch Med Wochennschr , vol.131 , pp. 1584-1589
    • Oppei, T.1    Schnuch, A.2
  • 7
    • 0344211507 scopus 로고    scopus 로고
    • Evaluation of metal allergies in patients with coronary stents
    • U. Hillen, M. Haude, R. Erbel, and M. Goos Evaluation of metal allergies in patients with coronary stents Contact Dermat 47 2002 353 356
    • (2002) Contact Dermat , vol.47 , pp. 353-356
    • Hillen, U.1    Haude, M.2    Erbel, R.3    Goos, M.4
  • 8
    • 73949122498 scopus 로고    scopus 로고
    • Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice (COMPARE): A randomised trial
    • E. Kedhi, K.S. Joesoef, and E. McFadden Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice (COMPARE): a randomised trial Lancet 375 2010 201 209
    • (2010) Lancet , vol.375 , pp. 201-209
    • Kedhi, E.1    Joesoef, K.S.2    McFadden, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.