메뉴 건너뛰기




Volumn 160, Issue 5, 2010, Pages 862-869

Early hemodynamic and neurohormonal response after transcatheter aortic valve implantation

Author keywords

[No Author keywords available]

Indexed keywords

AMINO TERMINAL PRO BRAIN NATRIURETIC PEPTIDE;

EID: 78649376716     PISSN: 00028703     EISSN: 10976744     Source Type: Journal    
DOI: 10.1016/j.ahj.2010.07.017     Document Type: Article
Times cited : (28)

References (26)
  • 1
    • 33847134400 scopus 로고    scopus 로고
    • Guidelines on the management of valvular heart disease: The Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology
    • Vahanian A., Baumgartner H., and Bax J. Guidelines on the management of valvular heart disease: The Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology Eur Heart J 28 2007 230 268
    • (2007) Eur Heart J , vol.28 , pp. 230-268
    • Vahanian, A.1    Baumgartner, H.2    Bax, J.3
  • 2
    • 67650562309 scopus 로고    scopus 로고
    • Transcatheter aortic valve replacement: A potential option for the nonsurgical patient
    • Patel J.H., Mathew S.T., and Hennebry T.A. Transcatheter aortic valve replacement: a potential option for the nonsurgical patient Clin Cardiol 32 2009 296 301
    • (2009) Clin Cardiol , vol.32 , pp. 296-301
    • Patel, J.H.1    Mathew, S.T.2    Hennebry, T.A.3
  • 3
    • 0031093725 scopus 로고    scopus 로고
    • Plasma levels of brain and atrial natriuretic peptides elevate in proportion to left ventricular end-systolic wall stress in patients with aortic stenosis
    • Ikeda T., Matsuda K., and Itoh H. Plasma levels of brain and atrial natriuretic peptides elevate in proportion to left ventricular end-systolic wall stress in patients with aortic stenosis Am Heart J 133 1997 307 314
    • (1997) Am Heart J , vol.133 , pp. 307-314
    • Ikeda, T.1    Matsuda, K.2    Itoh, H.3
  • 4
    • 33750334589 scopus 로고    scopus 로고
    • Prognostic value of N-terminal pro-B-type natriuretic peptide for conservatively and surgically treated patients with aortic valve stenosis
    • Weber M., Hausen M., and Arnold R. Prognostic value of N-terminal pro-B-type natriuretic peptide for conservatively and surgically treated patients with aortic valve stenosis Heart 92 2006 1639 1644
    • (2006) Heart , vol.92 , pp. 1639-1644
    • Weber, M.1    Hausen, M.2    Arnold, R.3
  • 5
    • 0036201748 scopus 로고    scopus 로고
    • The effect of aortic valve replacement on N-terminal natriuretic propeptides in patients with aortic stenosis
    • Qi W., Mathisen P., and Kjekshus J. The effect of aortic valve replacement on N-terminal natriuretic propeptides in patients with aortic stenosis Clin Cardiol 25 2002 174 180
    • (2002) Clin Cardiol , vol.25 , pp. 174-180
    • Qi, W.1    Mathisen, P.2    Kjekshus, J.3
  • 6
    • 0037446572 scopus 로고    scopus 로고
    • Increased plasma natriuretic peptide levels reflect symptom onset in aortic stenosis
    • Gerber I.L., Stewart R.A., and Legget M.E. Increased plasma natriuretic peptide levels reflect symptom onset in aortic stenosis Circulation 107 2003 1884 1890
    • (2003) Circulation , vol.107 , pp. 1884-1890
    • Gerber, I.L.1    Stewart, R.A.2    Legget, M.E.3
  • 7
    • 0034812918 scopus 로고    scopus 로고
    • Natriuretic peptides in patients with aortic stenosis
    • Qi W., Mathisen P., and Kjekshus J. Natriuretic peptides in patients with aortic stenosis Am Heart J 142 2001 725 732
    • (2001) Am Heart J , vol.142 , pp. 725-732
    • Qi, W.1    Mathisen, P.2    Kjekshus, J.3
  • 8
    • 34250815116 scopus 로고    scopus 로고
    • Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: Device success and 30-day clinical outcome
    • Grube E., Schuler G., and Buellesfeld L. Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome J Am Coll Cardiol 50 2007 69 76
    • (2007) J Am Coll Cardiol , vol.50 , pp. 69-76
    • Grube, E.1    Schuler, G.2    Buellesfeld, L.3
  • 9
    • 75349102866 scopus 로고    scopus 로고
    • Adherence to patient selection criteria in patients undergoing transcatheter aortic valve implantation with the 18F CoreValve ReValving System
    • Piazza N., Otten A., and Schultz C. Adherence to patient selection criteria in patients undergoing transcatheter aortic valve implantation with the 18F CoreValve ReValving System Heart 96 2010 19 26
    • (2010) Heart , vol.96 , pp. 19-26
    • Piazza, N.1    Otten, A.2    Schultz, C.3
  • 10
    • 44949195501 scopus 로고    scopus 로고
    • True percutaneous implantation of the CoreValve aortic valve prosthesis by the combined use of ultrasound guided vascular access, Prostar(R) XL and the TandemHeart(R)
    • de Jaegere P., van Dijk L.C., and Laborde J.C. True percutaneous implantation of the CoreValve aortic valve prosthesis by the combined use of ultrasound guided vascular access, Prostar(R) XL and the TandemHeart(R) EuroIntervention 2 2007 500 505
    • (2007) EuroIntervention , vol.2 , pp. 500-505
    • De Jaegere, P.1    Van Dijk, L.C.2    Laborde, J.C.3
  • 11
    • 0022649162 scopus 로고
    • Determination of the stenotic aortic valve area in adults using Doppler echocardiography
    • Otto C.M., Pearlman A.S., and Comess K.A. Determination of the stenotic aortic valve area in adults using Doppler echocardiography J Am Coll Cardiol 7 1986 509 517
    • (1986) J Am Coll Cardiol , vol.7 , pp. 509-517
    • Otto, C.M.1    Pearlman, A.S.2    Comess, K.A.3
  • 12
    • 0022588019 scopus 로고
    • Echocardiographic assessment of left ventricular hypertrophy: Comparison to necropsy findings
    • Devereux R.B., Alonso D.R., and Lutas E.M. Echocardiographic assessment of left ventricular hypertrophy: comparison to necropsy findings Am J Cardiol 57 1986 450 458
    • (1986) Am J Cardiol , vol.57 , pp. 450-458
    • Devereux, R.B.1    Alonso, D.R.2    Lutas, E.M.3
  • 13
    • 0142008980 scopus 로고    scopus 로고
    • Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography
    • Zoghbi W.A., Enriquez-Sarano M., and Foster E. Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography J Am Soc Echocardiogr 16 2003 777 802
    • (2003) J Am Soc Echocardiogr , vol.16 , pp. 777-802
    • Zoghbi, W.A.1    Enriquez-Sarano, M.2    Foster, E.3
  • 14
    • 0032019301 scopus 로고    scopus 로고
    • Valve prosthesis-patient mismatch: An update
    • Rahimtoola S.H. Valve prosthesis-patient mismatch: an update J Heart Valve Dis 7 1998 207 210
    • (1998) J Heart Valve Dis , vol.7 , pp. 207-210
    • Rahimtoola, S.H.1
  • 15
    • 0032801163 scopus 로고    scopus 로고
    • European System for Cardiac Operative Risk Evaluation (EuroSCORE)
    • Nashef S.A., Roques F., and Michel P. European System for Cardiac Operative Risk Evaluation (EuroSCORE) Eur J Cardiothorac Surg 16 1999 9 13
    • (1999) Eur J Cardiothorac Surg , vol.16 , pp. 9-13
    • Nashef, S.A.1    Roques, F.2    Michel, P.3
  • 16
    • 59049100066 scopus 로고    scopus 로고
    • Early echocardiographic evaluation following percutaneous implantation with the self-expanding CoreValve ReValving System aortic valve bioprosthesis
    • De Jaegere P.P., Piazza N., and Galema T.W. Early echocardiographic evaluation following percutaneous implantation with the self-expanding CoreValve ReValving System aortic valve bioprosthesis EuroIntervention 4 2008 351 357
    • (2008) EuroIntervention , vol.4 , pp. 351-357
    • De Jaegere, P.P.1    Piazza, N.2    Galema, T.W.3
  • 17
    • 0141989867 scopus 로고    scopus 로고
    • The Sorin pericardial bioprosthesis-a stentless aortic valve with very good hemodynamic performance
    • Gegouskov V.A., Eckstein F.S., and Kipfer B. The Sorin pericardial bioprosthesis-a stentless aortic valve with very good hemodynamic performance Swiss Surg 9 2003 247 252
    • (2003) Swiss Surg , vol.9 , pp. 247-252
    • Gegouskov, V.A.1    Eckstein, F.S.2    Kipfer, B.3
  • 18
    • 65149088915 scopus 로고    scopus 로고
    • Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis
    • Clavel M.A., Webb J.G., and Pibarot P. Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis J Am Coll Cardiol 53 2009 1883 1891
    • (2009) J Am Coll Cardiol , vol.53 , pp. 1883-1891
    • Clavel, M.A.1    Webb, J.G.2    Pibarot, P.3
  • 19
    • 33745042199 scopus 로고    scopus 로고
    • Is severe valve prosthesis-patient mismatch (VP-PM) associated with a higher mortality?
    • Rahimtoola S.H. Is severe valve prosthesis-patient mismatch (VP-PM) associated with a higher mortality? Eur J Cardiothorac Surg 30 2006 1
    • (2006) Eur J Cardiothorac Surg , vol.30 , pp. 1
    • Rahimtoola, S.H.1
  • 20
    • 55849132881 scopus 로고    scopus 로고
    • Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) CoreValve ReValving System: Results from the multicentre, expanded evaluation registry 1-year following CE mark approval
    • Piazza N., Grube E., and Gerckens U. Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) CoreValve ReValving System: results from the multicentre, expanded evaluation registry 1-year following CE mark approval EuroIntervention 4 2008 242 249
    • (2008) EuroIntervention , vol.4 , pp. 242-249
    • Piazza, N.1    Grube, E.2    Gerckens, U.3
  • 21
    • 0032790897 scopus 로고    scopus 로고
    • Natural history of early aortic paraprosthetic regurgitation: A five-year follow-up
    • Rallidis L.S., Moyssakis I.E., and Ikonomidis I. Natural history of early aortic paraprosthetic regurgitation: a five-year follow-up Am Heart J 138 1999 351 357
    • (1999) Am Heart J , vol.138 , pp. 351-357
    • Rallidis, L.S.1    Moyssakis, I.E.2    Ikonomidis, I.3
  • 22
    • 45549095219 scopus 로고    scopus 로고
    • Incidence, associated factors and evolution of non-severe functional mitral regurgitation in patients with severe aortic stenosis undergoing aortic valve replacement
    • Caballero-Borrego J., Gomez-Doblas J.J., and Cabrera-Bueno F. Incidence, associated factors and evolution of non-severe functional mitral regurgitation in patients with severe aortic stenosis undergoing aortic valve replacement Eur J Cardiothorac Surg 34 2008 62 66
    • (2008) Eur J Cardiothorac Surg , vol.34 , pp. 62-66
    • Caballero-Borrego, J.1    Gomez-Doblas, J.J.2    Cabrera-Bueno, F.3
  • 23
    • 58649088446 scopus 로고    scopus 로고
    • Echocardiography for transcatheter aortic valve implantation
    • Chin D. Echocardiography for transcatheter aortic valve implantation Eur J Echocardiogr 10 2009 i21 9
    • (2009) Eur J Echocardiogr , vol.10 , pp. 21-9
    • Chin, D.1
  • 24
    • 0035143708 scopus 로고    scopus 로고
    • Plasma N-terminal pro BNP and cardiotrophin-1 are elevated in aortic stenosis
    • Talwar S., Downie P.F., and Squire I.B. Plasma N-terminal pro BNP and cardiotrophin-1 are elevated in aortic stenosis Eur J Heart Fail 3 2001 15 19
    • (2001) Eur J Heart Fail , vol.3 , pp. 15-19
    • Talwar, S.1    Downie, P.F.2    Squire, I.B.3
  • 25
    • 78951492989 scopus 로고    scopus 로고
    • Clinical and hemodynamic predictors of natriuretic peptide elevation among aortic valve disease patients
    • Liska B., Khattab A.A., and Sherif M.A. Clinical and hemodynamic predictors of natriuretic peptide elevation among aortic valve disease patients Int J Cardiol 2009 10.1016/j.ijcard.2008.12.211 [E-pub ahead of print]
    • (2009) Int J Cardiol
    • Liska, B.1    Khattab, A.A.2    Sherif, M.A.3
  • 26
    • 33646355687 scopus 로고    scopus 로고
    • The effect of aortic valve replacement on plasma B-type natriuretic peptide in patients with severe aortic stenosis-one year follow-up
    • Neverdal N.O., Knudsen C.W., and Husebye T. The effect of aortic valve replacement on plasma B-type natriuretic peptide in patients with severe aortic stenosis-one year follow-up Eur J Heart Fail 8 2006 257 262
    • (2006) Eur J Heart Fail , vol.8 , pp. 257-262
    • Neverdal, N.O.1    Knudsen, C.W.2    Husebye, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.