메뉴 건너뛰기




Volumn 18, Issue 3, 2010, Pages 549-564

Imaging at higher magnetic fields: 3 T versus 1.5 T

Author keywords

1.5 T; 3 T; Contrast enhanced imaging; Diffusion weighted hepatobiliary imaging; Higher magnetic fields; Non contrast enhanced imaging

Indexed keywords

CONTRAST MEDIUM; GADOBENIC ACID; GADOBUTROL; GADODIAMIDE; GADOLINIUM; GADOLINIUM PENTETATE; GADOTERATE MEGLUMINE; GADOTERIDOL; GADOVERSETAMIDE; GADOXETIC ACID;

EID: 78649271307     PISSN: 10649689     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mric.2010.08.008     Document Type: Review
Times cited : (17)

References (35)
  • 1
    • 77449127465 scopus 로고    scopus 로고
    • Diffuse liver disease: strategies for hepatic CT and MR imaging
    • Boll D.T., Merkle E.M. Diffuse liver disease: strategies for hepatic CT and MR imaging. Radiographics 2009, 29:1591-1614.
    • (2009) Radiographics , vol.29 , pp. 1591-1614
    • Boll, D.T.1    Merkle, E.M.2
  • 2
    • 33745503397 scopus 로고    scopus 로고
    • Abdominal MRI at 3.0 T: the basics revisited
    • Merkle E.M., Dale B.M. Abdominal MRI at 3.0 T: the basics revisited. AJR Am J Roentgenol 2006, 186:1524-1532.
    • (2006) AJR Am J Roentgenol , vol.186 , pp. 1524-1532
    • Merkle, E.M.1    Dale, B.M.2
  • 3
    • 33748577687 scopus 로고    scopus 로고
    • Abdominal magnetic resonance imaging at 3.0 T what is the ultimate gain in signal-to-noise ratio?
    • Schindera S.T., Merkle E.M., Dale B.M., et al. Abdominal magnetic resonance imaging at 3.0 T what is the ultimate gain in signal-to-noise ratio?. Acad Radiol 2006, 13:1236-1243.
    • (2006) Acad Radiol , vol.13 , pp. 1236-1243
    • Schindera, S.T.1    Merkle, E.M.2    Dale, B.M.3
  • 4
    • 1342330052 scopus 로고    scopus 로고
    • MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: preliminary results
    • de Bazelaire C.M., Duhamel G.D., Rofsky N.M., et al. MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: preliminary results. Radiology 2004, 230:652-659.
    • (2004) Radiology , vol.230 , pp. 652-659
    • de Bazelaire, C.M.1    Duhamel, G.D.2    Rofsky, N.M.3
  • 6
    • 77950613420 scopus 로고    scopus 로고
    • Pilot study assessing differentiation of steatosis hepatis, hepatic iron overload, and combined disease using two-point Dixon MRI at 3 T: in vitro and in vivo results of a 2D decomposition technique
    • Boll D.T., Marin D., Redmon G.M., et al. Pilot study assessing differentiation of steatosis hepatis, hepatic iron overload, and combined disease using two-point Dixon MRI at 3 T: in vitro and in vivo results of a 2D decomposition technique. AJR Am J Roentgenol 2010, 194:964-971.
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 964-971
    • Boll, D.T.1    Marin, D.2    Redmon, G.M.3
  • 7
    • 0027299367 scopus 로고
    • Value of T1 and T2 relaxation times from echoplanar MR imaging in the characterization of focal hepatic lesions
    • Goldberg M.A., Hahn P.F., Saini S., et al. Value of T1 and T2 relaxation times from echoplanar MR imaging in the characterization of focal hepatic lesions. AJR Am J Roentgenol 1993, 160:1011-1017.
    • (1993) AJR Am J Roentgenol , vol.160 , pp. 1011-1017
    • Goldberg, M.A.1    Hahn, P.F.2    Saini, S.3
  • 8
    • 0025849046 scopus 로고
    • Liver imaging at 1.5 Tesla: pulse sequence optimization based on improved measurement of tissue relaxation times
    • Van Lom K.J., Brown J.J., Perman W.H., et al. Liver imaging at 1.5 Tesla: pulse sequence optimization based on improved measurement of tissue relaxation times. Magn Reson Imaging 1991, 9:165-171.
    • (1991) Magn Reson Imaging , vol.9 , pp. 165-171
    • Van Lom, K.J.1    Brown, J.J.2    Perman, W.H.3
  • 9
    • 24144448806 scopus 로고    scopus 로고
    • T1, T2 relaxation and magnetization transfer in tissue at 3T
    • Stanisz G.J., Odrobina E.E., Pun J., et al. T1, T2 relaxation and magnetization transfer in tissue at 3T. Magn Reson Med 2005, 54:507-512.
    • (2005) Magn Reson Med , vol.54 , pp. 507-512
    • Stanisz, G.J.1    Odrobina, E.E.2    Pun, J.3
  • 11
    • 33645754197 scopus 로고    scopus 로고
    • Contrast behavior and relaxation effects of conventional and hyperecho-turbo spin echo sequences at 1.5 and 3 T
    • Weigel M., Hennig J. Contrast behavior and relaxation effects of conventional and hyperecho-turbo spin echo sequences at 1.5 and 3 T. Magn Reson Med 2006, 55:826-835.
    • (2006) Magn Reson Med , vol.55 , pp. 826-835
    • Weigel, M.1    Hennig, J.2
  • 12
    • 4243086933 scopus 로고    scopus 로고
    • Variable-rate selective excitation for rapid MRI sequences
    • Hargreaves B.A., Cunningham C.H., Nishimura D.G., et al. Variable-rate selective excitation for rapid MRI sequences. Magn Reson Med 2004, 52:590-597.
    • (2004) Magn Reson Med , vol.52 , pp. 590-597
    • Hargreaves, B.A.1    Cunningham, C.H.2    Nishimura, D.G.3
  • 14
    • 27544442176 scopus 로고    scopus 로고
    • Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths
    • Rohrer M., Bauer H., Mintorovitch J., et al. Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths. Invest Radiol 2005, 40:715-724.
    • (2005) Invest Radiol , vol.40 , pp. 715-724
    • Rohrer, M.1    Bauer, H.2    Mintorovitch, J.3
  • 15
    • 34247881894 scopus 로고    scopus 로고
    • MR contrast agents: physical and pharmacologic basics
    • Lin S.P., Brown J.J. MR contrast agents: physical and pharmacologic basics. J Magn Reson Imaging 2007, 25:884-899.
    • (2007) J Magn Reson Imaging , vol.25 , pp. 884-899
    • Lin, S.P.1    Brown, J.J.2
  • 16
    • 15844425224 scopus 로고    scopus 로고
    • Liver tumors: comparison of MR imaging with Gd-EOB-DTPA and Gd-DTPA
    • Vogl T.J., Kummel S., Hammerstingl R., et al. Liver tumors: comparison of MR imaging with Gd-EOB-DTPA and Gd-DTPA. Radiology 1996, 200:59-67.
    • (1996) Radiology , vol.200 , pp. 59-67
    • Vogl, T.J.1    Kummel, S.2    Hammerstingl, R.3
  • 17
    • 10744225741 scopus 로고    scopus 로고
    • Implications of SENSE MR in routine clinical practice
    • van den Brink J.S., Watanabe Y., Kuhl C.K., et al. Implications of SENSE MR in routine clinical practice. Eur J Radiol 2003, 46:3-27.
    • (2003) Eur J Radiol , vol.46 , pp. 3-27
    • van den Brink, J.S.1    Watanabe, Y.2    Kuhl, C.K.3
  • 19
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays
    • Sodickson D.K., Manning W.J. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997, 38:591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 20
    • 0033856106 scopus 로고    scopus 로고
    • Tailored SMASH image reconstructions for robust in vivo parallel MR imaging
    • Sodickson D.K. Tailored SMASH image reconstructions for robust in vivo parallel MR imaging. Magn Reson Med 2000, 44:243-251.
    • (2000) Magn Reson Med , vol.44 , pp. 243-251
    • Sodickson, D.K.1
  • 21
    • 0034845169 scopus 로고    scopus 로고
    • A generalized approach to parallel magnetic resonance imaging
    • Sodickson D.K., McKenzie C.A. A generalized approach to parallel magnetic resonance imaging. Med Phys 2001, 28:1629-1643.
    • (2001) Med Phys , vol.28 , pp. 1629-1643
    • Sodickson, D.K.1    McKenzie, C.A.2
  • 22
    • 0021132985 scopus 로고
    • Simple proton spectroscopic imaging
    • Dixon W.T. Simple proton spectroscopic imaging. Radiology 1984, 153:189-194.
    • (1984) Radiology , vol.153 , pp. 189-194
    • Dixon, W.T.1
  • 23
    • 0021200259 scopus 로고
    • Fatty infiltration of the liver: demonstration by proton spectroscopic imaging. Preliminary observations
    • Lee J.K., Dixon W.T., Ling D., et al. Fatty infiltration of the liver: demonstration by proton spectroscopic imaging. Preliminary observations. Radiology 1984, 153:195-201.
    • (1984) Radiology , vol.153 , pp. 195-201
    • Lee, J.K.1    Dixon, W.T.2    Ling, D.3
  • 24
    • 0032882776 scopus 로고    scopus 로고
    • Abdominal MR imaging with a volumetric interpolated breath-hold examination
    • Rofsky N.M., Lee V.S., Laub G., et al. Abdominal MR imaging with a volumetric interpolated breath-hold examination. Radiology 1999, 212:876-884.
    • (1999) Radiology , vol.212 , pp. 876-884
    • Rofsky, N.M.1    Lee, V.S.2    Laub, G.3
  • 25
    • 71849117321 scopus 로고    scopus 로고
    • Quantitative and qualitative comparison of 3.0T and 1.5T MR imaging of the liver in patients with diffuse parenchymal liver disease
    • Tsurusaki M., Semelka R.C., Zapparoli M., et al. Quantitative and qualitative comparison of 3.0T and 1.5T MR imaging of the liver in patients with diffuse parenchymal liver disease. Eur J Radiol 2009, 72:314-320.
    • (2009) Eur J Radiol , vol.72 , pp. 314-320
    • Tsurusaki, M.1    Semelka, R.C.2    Zapparoli, M.3
  • 26
    • 40949092665 scopus 로고    scopus 로고
    • Focal liver lesion detection and characterization with diffusion-weighted MR imaging: comparison with standard breath-hold T2-weighted imaging
    • Parikh T., Drew S.J., Lee V.S., et al. Focal liver lesion detection and characterization with diffusion-weighted MR imaging: comparison with standard breath-hold T2-weighted imaging. Radiology 2008, 246:812-822.
    • (2008) Radiology , vol.246 , pp. 812-822
    • Parikh, T.1    Drew, S.J.2    Lee, V.S.3
  • 27
    • 39049083433 scopus 로고    scopus 로고
    • Characterization of focal liver lesions by ADC measurements using a respiratory triggered diffusion-weighted single-shot echo-planar MR imaging technique
    • Bruegel M., Holzapfel K., Gaa J., et al. Characterization of focal liver lesions by ADC measurements using a respiratory triggered diffusion-weighted single-shot echo-planar MR imaging technique. Eur Radiol 2008, 18:477-485.
    • (2008) Eur Radiol , vol.18 , pp. 477-485
    • Bruegel, M.1    Holzapfel, K.2    Gaa, J.3
  • 28
    • 0029896023 scopus 로고    scopus 로고
    • Needle localization in MR-guided biopsy and aspiration: effects of field strength, sequence design, and magnetic field orientation
    • Lewin J.S., Duerk J.L., Jain V.R., et al. Needle localization in MR-guided biopsy and aspiration: effects of field strength, sequence design, and magnetic field orientation. AJR Am J Roentgenol 1996, 166:1337-1345.
    • (1996) AJR Am J Roentgenol , vol.166 , pp. 1337-1345
    • Lewin, J.S.1    Duerk, J.L.2    Jain, V.R.3
  • 29
    • 33749471991 scopus 로고    scopus 로고
    • Dual gradient-echo in-phase and opposed-phase hepatic MR imaging: a useful tool for evaluating more than fatty infiltration or fatty sparing
    • Merkle E.M., Nelson R.C. Dual gradient-echo in-phase and opposed-phase hepatic MR imaging: a useful tool for evaluating more than fatty infiltration or fatty sparing. Radiographics 2006, 26:1409-1418.
    • (2006) Radiographics , vol.26 , pp. 1409-1418
    • Merkle, E.M.1    Nelson, R.C.2
  • 30
    • 33748452231 scopus 로고    scopus 로고
    • Pneumobilia: where to look for on hepatic MR imaging?
    • Merkle E.M. Pneumobilia: where to look for on hepatic MR imaging?. Eur Radiol 2006, 16:2366-2368.
    • (2006) Eur Radiol , vol.16 , pp. 2366-2368
    • Merkle, E.M.1
  • 31
    • 33748466473 scopus 로고    scopus 로고
    • MR liver imaging and cholangiography in the presence of surgical metallic clips at 1.5 and 3 Tesla
    • Merkle E.M., Dale B.M., Thomas J., et al. MR liver imaging and cholangiography in the presence of surgical metallic clips at 1.5 and 3 Tesla. Eur Radiol 2006, 16:2309-2316.
    • (2006) Eur Radiol , vol.16 , pp. 2309-2316
    • Merkle, E.M.1    Dale, B.M.2    Thomas, J.3
  • 32
    • 22844444193 scopus 로고    scopus 로고
    • Whole-body MRI at high field: technical limits and clinical potential
    • Schick F. Whole-body MRI at high field: technical limits and clinical potential. Eur Radiol 2005, 15:946-959.
    • (2005) Eur Radiol , vol.15 , pp. 946-959
    • Schick, F.1
  • 33
    • 12744262814 scopus 로고    scopus 로고
    • Central brightening due to constructive interference with, without, and despite dielectric resonance
    • Collins C.M., Liu W., Schreiber W., et al. Central brightening due to constructive interference with, without, and despite dielectric resonance. J Magn Reson Imaging 2005, 21:192-196.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 192-196
    • Collins, C.M.1    Liu, W.2    Schreiber, W.3
  • 34
    • 0031865774 scopus 로고    scopus 로고
    • A spiral volume coil for improved RF field homogeneity at high static magnetic field strength
    • Alsop D.C., Connick T.J., Mizsei G. A spiral volume coil for improved RF field homogeneity at high static magnetic field strength. Magn Reson Med 1998, 40:49-54.
    • (1998) Magn Reson Med , vol.40 , pp. 49-54
    • Alsop, D.C.1    Connick, T.J.2    Mizsei, G.3
  • 35
    • 44449139521 scopus 로고    scopus 로고
    • Improvement in B1-inhomogeneity artifacts in the abdomen at 3T MR imaging using a radiofrequency cushion
    • Franklin K.M., Dale B.M., Merkle E.M. Improvement in B1-inhomogeneity artifacts in the abdomen at 3T MR imaging using a radiofrequency cushion. J Magn Reson Imaging 2008, 27:1443-1447.
    • (2008) J Magn Reson Imaging , vol.27 , pp. 1443-1447
    • Franklin, K.M.1    Dale, B.M.2    Merkle, E.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.