메뉴 건너뛰기




Volumn 51, Issue 4, 2010, Pages 515-531

Device-specific outcomes after endovascular abdominal aortic aneurysm repair

Author keywords

Aortic aneurysm, abdominal; Blood vessel prosthesis; Blood vessel prosthesis implantation; Treatment outcome

Indexed keywords

POLITEF; POLYESTER; TITANIUM;

EID: 78649267887     PISSN: 00219509     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (10)

References (79)
  • 1
    • 0026267990 scopus 로고
    • Clinical experience of the use of self-fixing synthetic prostheses for remote endoprosthetics of the thoracic and the abdominal aorta and iliac arteries through the femoral artery and as intraoperative endoprosthesis for aorta reconstruction
    • Volodos NL, Karpovich IP, Troyan VI, Kalashnikova YuV, Shekhanin VE, Ternyuk NE et al. Clinical experience of the use of self-fixing synthetic prostheses for remote endoprosthetics of the thoracic and the abdominal aorta and iliac arteries through the femoral artery and as intraoperative endoprosthesis for aorta reconstruction. Vasa Suppl 1991;33:93-5.
    • (1991) Vasa Suppl , vol.33 , pp. 93-95
    • Volodos, N.L.1    Karpovich, I.P.2    Troyan, V.I.3    Kalashnikova, Yu.V.4    Shekhanin, V.E.5    Ternyuk, N.E.6
  • 2
    • 0026321992 scopus 로고
    • Transfemoral intraluminal graft implantation for abdominal aortic aneurysms
    • Parodi JC, Palmaz JC, Barone HD. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 1991;5:491-9.
    • (1991) Ann Vasc Surg , vol.5 , pp. 491-499
    • Parodi, J.C.1    Palmaz, J.C.2    Barone, H.D.3
  • 3
    • 77952609639 scopus 로고    scopus 로고
    • Endovascular repair of aortic aneurysm in patients physically ineligible for open repair
    • Greenhalgh RM, Brown LC, Powell JT, Thompson SG, Epstein D. Endovascular repair of aortic aneurysm in patients physically ineligible for open repair. N Engl J Med 2010;362:1872-80.
    • (2010) N Engl J Med , vol.362 , pp. 1872-1880
    • Greenhalgh, R.M.1    Brown, L.C.2    Powell, J.T.3    Thompson, S.G.4    Epstein, D.5
  • 7
    • 22044446554 scopus 로고    scopus 로고
    • Lifeline registry of endovascular aneurysm repair: Long-term primary outcome measures
    • Lifeline registry of endovascular aneurysm repair: long-term primary outcome measures. J Vasc Surg 2005;42:1-10.
    • (2005) J Vasc Surg , vol.42 , pp. 1-10
  • 8
    • 0034596498 scopus 로고    scopus 로고
    • Endovascular stenting of abdominal aortic aneurysm in patients unfit for elective open surgery
    • Eurostar group. EUROpean collaborators registry on Stent-graft Techniques for abdominal aortic Aneurysm Repair
    • Laheij RJ, van Marrewijk CJ. Endovascular stenting of abdominal aortic aneurysm in patients unfit for elective open surgery. Eurostar group. EUROpean collaborators registry on Stent-graft Techniques for abdominal aortic Aneurysm Repair. Lancet 2000;356:832.
    • (2000) Lancet , vol.356 , pp. 832
    • Laheij, R.J.1    Van Marrewijk, C.J.2
  • 9
    • 67649969186 scopus 로고    scopus 로고
    • Endovascular repair vs open surgical repair of abdominal aortic aneurysms: Comparative utilization trends from 2001 to 2006
    • Levin DC, Rao VM, Parker L, Frangos AJ, Sunshine JH. Endovascular repair vs open surgical repair of abdominal aortic aneurysms: comparative utilization trends from 2001 to 2006. J Am Coll Radiol 2009;6:506-9.
    • (2009) J Am Coll Radiol , vol.6 , pp. 506-509
    • Levin, D.C.1    Rao, V.M.2    Parker, L.3    Frangos, A.J.4    Sunshine, J.H.5
  • 10
    • 0036733325 scopus 로고    scopus 로고
    • Endograft migration one to four years after endovascular abdominal aortic aneurysm repair with the AneuRx device: A cautionary note
    • Conners MS, 3rd, Sternbergh WC, 3rd, Carter G, Tonnessen BH, Yoselevitz M, Money SR. Endograft migration one to four years after endovascular abdominal aortic aneurysm repair with the AneuRx device: a cautionary note. J Vasc Surg 2002;36:476-84.
    • (2002) J Vasc Surg , vol.36 , pp. 476-484
    • Conners III, M.S.1    Sternbergh III, W.C.2    Carter, G.3    Tonnessen, B.H.4    Yoselevitz, M.5    Money, S.R.6
  • 11
    • 0037380847 scopus 로고    scopus 로고
    • The US AneuRx Clinical Trial: 6-year clinical update 2002
    • Zarins CK. The US AneuRx Clinical Trial: 6-year clinical update 2002. J Vasc Surg 2003;37:904-8.
    • (2003) J Vasc Surg , vol.37 , pp. 904-908
    • Zarins, C.K.1
  • 12
    • 21044444277 scopus 로고    scopus 로고
    • AneuRx device migration: Incidence, risk factors, and consequences
    • Sampaio SM, Panneton JM, Mozes G, et al. AneuRx device migration: incidence, risk factors, and consequences. Ann Vasc Surg 2005;19:178-85.
    • (2005) Ann Vasc Surg , vol.19 , pp. 178-185
    • Sampaio, S.M.1    Panneton, J.M.2    Mozes, G.3
  • 13
    • 23344453940 scopus 로고    scopus 로고
    • Risk-adjusted outcome analysis of endovascular abdominal aortic aneurysm repair in a large population: How do stentgrafts compare?
    • van Marrewijk CJ, Leurs LJ, Vallabhaneni SR, Harris PL, Buth J, Laheij RJ. Risk-adjusted outcome analysis of endovascular abdominal aortic aneurysm repair in a large population: how do stentgrafts compare? J Endovasc Ther 2005;12:417-29.
    • (2005) J Endovasc Ther , vol.12 , pp. 417-429
    • Van Marrewijk, C.J.1    Leurs, L.J.2    Vallabhaneni, S.R.3    Harris, P.L.4    Buth, J.5    Laheij, R.J.6
  • 14
    • 0346964283 scopus 로고    scopus 로고
    • Influence of endograft oversizing on device migration, endoleak, aneurysm shrinkage, and aortic neck dilation: Results from the Zenith Multicenter Trial
    • Sternbergh WC, 3rd, Money SR, Greenberg RK, Chuter TA. Influence of endograft oversizing on device migration, endoleak, aneurysm shrinkage, and aortic neck dilation: results from the Zenith Multicenter Trial. J Vasc Surg 2004;39:20-6.
    • (2004) J Vasc Surg , vol.39 , pp. 20-26
    • Sternbergh III, W.C.1    Money, S.R.2    Greenberg, R.K.3    Chuter, T.A.4
  • 15
    • 0037326088 scopus 로고    scopus 로고
    • A multicenter controlled clinical trial of open versus endovascular treatment of abdominal aortic aneurysm
    • Matsumura JS, Brewster DC, Makaroun MS, Naftel DC. A multicenter controlled clinical trial of open versus endovascular treatment of abdominal aortic aneurysm. J Vasc Surg 2003;37:262-71.
    • (2003) J Vasc Surg , vol.37 , pp. 262-271
    • Matsumura, J.S.1    Brewster, D.C.2    Makaroun, M.S.3    Naftel, D.C.4
  • 16
    • 77952302425 scopus 로고    scopus 로고
    • Endovascular repair compared with surveillance for patients with small abdominal aortic aneurysms
    • Ouriel K, Clair DG, Kent KC, Zarins CK. Endovascular repair compared with surveillance for patients with small abdominal aortic aneurysms. J Vasc Surg 2010;51:1081-7.
    • (2010) J Vasc Surg , vol.51 , pp. 1081-1087
    • Ouriel, K.1    Clair, D.G.2    Kent, K.C.3    Zarins, C.K.4
  • 17
    • 0034042336 scopus 로고    scopus 로고
    • Aneurysm rupture after endovascular repair using the AneuRx stent graft
    • Zarins CK, White RA, Fogarty TJ. Aneurysm rupture after endovascular repair using the AneuRx stent graft. J Vasc Surg 2000;31:960-70.
    • (2000) J Vasc Surg , vol.31 , pp. 960-970
    • Zarins, C.K.1    White, R.A.2    Fogarty, T.J.3
  • 20
    • 33847176605 scopus 로고    scopus 로고
    • Influence of severe infrarenal aortic neck angulation on complications at the proximal neck following endovascular AAA repair: A EUROSTAR study
    • Hobo R, Kievit J, Leurs LJ, Buth J. Influence of severe infrarenal aortic neck angulation on complications at the proximal neck following endovascular AAA repair: a EUROSTAR study. J Endovasc Ther 2007;14:1-11.
    • (2007) J Endovasc Ther , vol.14 , pp. 1-11
    • Hobo, R.1    Kievit, J.2    Leurs, L.J.3    Buth, J.4
  • 21
    • 77950409703 scopus 로고    scopus 로고
    • Endoluminal abdominal aortic aneurysm repair: The latest advances in prevention of distal endograft migration and type 1 endoleak
    • Ghouri M, Krajcer Z. Endoluminal abdominal aortic aneurysm repair: the latest advances in prevention of distal endograft migration and type 1 endoleak. Tex Heart Inst J 2010;37:19-24.
    • (2010) Tex Heart Inst J , vol.37 , pp. 19-24
    • Ghouri, M.1    Krajcer, Z.2
  • 22
    • 84944180416 scopus 로고    scopus 로고
    • The endowedge and kilt techniques to achieve additional juxtarenal seal during deployment of the Gore Excluder endoprosthesis
    • Minion DJ, Yancey A, Patterson DE, Saha S, Endean ED. The endowedge and kilt techniques to achieve additional juxtarenal seal during deployment of the Gore Excluder endoprosthesis. Ann Vasc Surg 2006;20:472-7.
    • (2006) Ann Vasc Surg , vol.20 , pp. 472-477
    • Minion, D.J.1    Yancey, A.2    Patterson, D.E.3    Saha, S.4    Endean, E.D.5
  • 25
    • 33646148034 scopus 로고    scopus 로고
    • Three-dimensional analysis of enlarging aneurysms after endovascular abdominal aortic aneurysm repair in the Gore Excluder Pivotal clinical trial
    • Fillinger M. Three-dimensional analysis of enlarging aneurysms after endovascular abdominal aortic aneurysm repair in the Gore Excluder Pivotal clinical trial. J Vasc Surg 2006;43:888-95.
    • (2006) J Vasc Surg , vol.43 , pp. 888-895
    • Fillinger, M.1
  • 26
    • 41149168021 scopus 로고    scopus 로고
    • Device-specific aneurysm sac morphology after endovascular aneurysm repair: Evaluation of contemporary graft materials
    • discussion 7
    • Broker HS, Foteh KI, Murphy EH, Davis CM, Clagett GP, Modrall JG et al. Device-specific aneurysm sac morphology after endovascular aneurysm repair: evaluation of contemporary graft materials. J Vasc Surg 2008;47:702-6; discussion 7.
    • (2008) J Vasc Surg , vol.47 , pp. 702-706
    • Broker, H.S.1    Foteh, K.I.2    Murphy, E.H.3    Davis, C.M.4    Clagett, G.P.5    Modrall, J.G.6
  • 27
    • 33846409828 scopus 로고    scopus 로고
    • Outcomes of original and low-permeability Gore Excluder endoprosthesis for endovascular abdominal aortic aneurysm repair
    • Tanski W, 3rd, Fillinger M. Outcomes of original and low-permeability Gore Excluder endoprosthesis for endovascular abdominal aortic aneurysm repair. J Vasc Surg 2007;45:243-9.
    • (2007) J Vasc Surg , vol.45 , pp. 243-249
    • Tanski III, W.1    Fillinger, M.2
  • 28
    • 33748953951 scopus 로고    scopus 로고
    • Sac behavior after aneurysm treatment with the Gore Excluder low-permeability aortic endoprosthesis: 12-month comparison to the original Excluder device
    • Haider SE, Najjar SF, Cho JS, Rhee RY, Eskandari MK, Matsumura JS et al. Sac behavior after aneurysm treatment with the Gore Excluder low-permeability aortic endoprosthesis: 12-month comparison to the original Excluder device. J Vasc Surg 2006;44:694-700.
    • (2006) J Vasc Surg , vol.44 , pp. 694-700
    • Haider, S.E.1    Najjar, S.F.2    Cho, J.S.3    Rhee, R.Y.4    Eskandari, M.K.5    Matsumura, J.S.6
  • 29
    • 33947580624 scopus 로고    scopus 로고
    • The effect of endograft relining on sac expansion after endovascular aneurysm repair with the original-permeability Gore Excluder abdominal aortic aneurysm endoprosthesis
    • Goodney PP, Fillinger MF. The effect of endograft relining on sac expansion after endovascular aneurysm repair with the original-permeability Gore Excluder abdominal aortic aneurysm endoprosthesis. J Vasc Surg 2007;45:686-93.
    • (2007) J Vasc Surg , vol.45 , pp. 686-693
    • Goodney, P.P.1    Fillinger, M.F.2
  • 30
    • 3242691741 scopus 로고    scopus 로고
    • Late abdominal aortic aneurysm enlargement after endovascular repair with the Excluder device
    • discussion 2141-2
    • Cho JS, Dillavou ED, Rhee RY, Makaroun MS. Late abdominal aortic aneurysm enlargement after endovascular repair with the Excluder device. J Vasc Surg 2004;39:1236-41; discussion 2141-2.
    • (2004) J Vasc Surg , vol.39 , pp. 1236-1241
    • Cho, J.S.1    Dillavou, E.D.2    Rhee, R.Y.3    Makaroun, M.S.4
  • 32
    • 32344435965 scopus 로고    scopus 로고
    • Long-term outcome after Talent endograft implantation for aneurysms of the abdominal aorta: A multicenter retrospective study
    • discussion 84
    • Torsello G, Osada N, Florek HJ, Horsch S, Kortmann H, Luska G et al. Long-term outcome after Talent endograft implantation for aneurysms of the abdominal aorta: a multicenter retrospective study. J Vasc Surg 2006;43:277-84; discussion 84.
    • (2006) J Vasc Surg , vol.43 , pp. 277-284
    • Torsello, G.1    Osada, N.2    Florek, H.J.3    Horsch, S.4    Kortmann, H.5    Luska, G.6
  • 33
    • 0035111954 scopus 로고    scopus 로고
    • Gender-related differences in infrarenal aortic aneurysm morphologic features: Issues relevant to Ancure and Talent endografts
    • Velazquez OC, Larson RA, Baum RA, Carpenter JP, Golden MA, Mitchell ME et al. Gender-related differences in infrarenal aortic aneurysm morphologic features: issues relevant to Ancure and Talent endografts. J Vasc Surg 2001;33:S77-84.
    • (2001) J Vasc Surg , vol.33
    • Velazquez, O.C.1    Larson, R.A.2    Baum, R.A.3    Carpenter, J.P.4    Golden, M.A.5    Mitchell, M.E.6
  • 34
    • 33748968522 scopus 로고    scopus 로고
    • Barriers to endovascular aortic aneurysm repair: Past experience and implications for future device development
    • Moise MA, Woo EY, Velazquez OC, Fairman RM, Golden MA, Mitchell ME et al. Barriers to endovascular aortic aneurysm repair: past experience and implications for future device development. Vasc Endovascular Surg 2006;40:197-203.
    • (2006) Vasc Endovascular Surg , vol.40 , pp. 197-203
    • Moise, M.A.1    Woo, E.Y.2    Velazquez, O.C.3    Fairman, R.M.4    Golden, M.A.5    Mitchell, M.E.6
  • 35
    • 7244253111 scopus 로고    scopus 로고
    • Relationship of proximal fixation to renal dysfunction in patients undergoing endovascular aneurysm repair
    • (Torino)
    • Mehta M, Cayne N, Veith FJ, Darling RC 3rd, Roddy SP, Paty PS et al. Relationship of proximal fixation to renal dysfunction in patients undergoing endovascular aneurysm repair. J Cardiovasc Surg (Torino) 2004;45:367-74.
    • (2004) J Cardiovasc Surg , vol.45 , pp. 367-374
    • Mehta, M.1    Cayne, N.2    Veith, F.J.3    Darling III, R.C.4    Roddy, S.P.5    Paty, P.S.6
  • 36
    • 30544452119 scopus 로고    scopus 로고
    • Endovascular aneurysm repair with suprarenal vs infrarenal fixation: A study of renal effects
    • Parmer SS, Carpenter JP. Endovascular aneurysm repair with suprarenal vs infrarenal fixation: a study of renal effects. J Vasc Surg 2006;43:19-25.
    • (2006) J Vasc Surg , vol.43 , pp. 19-25
    • Parmer, S.S.1    Carpenter, J.P.2
  • 37
    • 39749124427 scopus 로고    scopus 로고
    • Impact on renal function after endovascular aneurysm repair with uncovered supra-renal fixation assessed by serum cystatin C
    • Davey P, Peaston R, Rose JD, Jackson RA, Wyatt MG. Impact on renal function after endovascular aneurysm repair with uncovered supra-renal fixation assessed by serum cystatin C. Eur J Vasc Endovasc Surg 2008;35:439-45.
    • (2008) Eur J Vasc Endovasc Surg , vol.35 , pp. 439-445
    • Davey, P.1    Peaston, R.2    Rose, J.D.3    Jackson, R.A.4    Wyatt, M.G.5
  • 38
    • 34248645980 scopus 로고    scopus 로고
    • Renal function after endovascular aortic aneurysm repair: A single-center experience with transrenal versus infrarenal fixation
    • Waasdorp E, van't Hullenaar C, van Herwaarden J, Kelder H, van de Pavoordt E, Overtoom T et al. Renal function after endovascular aortic aneurysm repair: a single-center experience with transrenal versus infrarenal fixation. J Endovasc Ther 2007;14:130-7.
    • (2007) J Endovasc Ther , vol.14 , pp. 130-137
    • Waasdorp, E.1    Van't Hullenaar, C.2    Van Herwaarden, J.3    Kelder, H.4    Van De Pavoordt, E.5    Overtoom, T.6
  • 40
    • 34547572339 scopus 로고    scopus 로고
    • Secondary interventions and mortality following endovascular aortic aneurysm repair: Device-specific results from the UK EVAR trials
    • Brown LC, Greenhalgh RM, Kwong GP, Powell JT, Thompson SG, Wyatt MG. Secondary interventions and mortality following endovascular aortic aneurysm repair: device-specific results from the UK EVAR trials. Eur J Vasc Endovasc Surg 2007;34:281-90.
    • (2007) Eur J Vasc Endovasc Surg , vol.34 , pp. 281-290
    • Brown, L.C.1    Greenhalgh, R.M.2    Kwong, G.P.3    Powell, J.T.4    Thompson, S.G.5    Wyatt, M.G.6
  • 42
    • 27644592801 scopus 로고    scopus 로고
    • Aneurysm diameter and proximal aortic neck diameter influence clinical outcome of endovascular abdominal aortic repair: A 4-year EUROSTAR experience
    • Waasdorp EJ, de Vries JP, Hobo R, Leurs LJ, Buth J, Moll FL. Aneurysm diameter and proximal aortic neck diameter influence clinical outcome of endovascular abdominal aortic repair: a 4-year EUROSTAR experience. Ann Vasc Surg 2005;19:755-61.
    • (2005) Ann Vasc Surg , vol.19 , pp. 755-761
    • Waasdorp, E.J.1    De Vries, J.P.2    Hobo, R.3    Leurs, L.J.4    Buth, J.5    Moll, F.L.6
  • 43
    • 49749097899 scopus 로고    scopus 로고
    • The Powerlink system for endovascular abdominal aortic aneurysm repair: Six-year results
    • Wang GJ, Carpenter JP. The Powerlink system for endovascular abdominal aortic aneurysm repair: six-year results. J Vasc Surg 2008;48:535-45.
    • (2008) J Vasc Surg , vol.48 , pp. 535-545
    • Wang, G.J.1    Carpenter, J.P.2
  • 44
    • 30744456283 scopus 로고    scopus 로고
    • Endovascular repair of abdominal aortic aneurysms with a unibody stent-graft: 3-year results of the French Powerlink Multicenter Trial
    • Albertini JN, Lahlou Z, Magnan PE, Branchereau A. Endovascular repair of abdominal aortic aneurysms with a unibody stent-graft: 3-year results of the French Powerlink Multicenter Trial. J Endovasc Ther 2005;12:629-37.
    • (2005) J Endovasc Ther , vol.12 , pp. 629-637
    • Albertini, J.N.1    Lahlou, Z.2    Magnan, P.E.3    Branchereau, A.4
  • 45
    • 67650490741 scopus 로고    scopus 로고
    • From clinical trials to clinical practice: 612 cases treated with the Powerlink stent-graft for endovascular repair of AAA
    • (Torino)
    • Qu L, Raithel D. From clinical trials to clinical practice: 612 cases treated with the Powerlink stent-graft for endovascular repair of AAA. J Cardiovasc Surg (Torino) 2009;50:131-7.
    • (2009) J Cardiovasc Surg , vol.50 , pp. 131-137
    • Qu, L.1    Raithel, D.2
  • 46
    • 3242714354 scopus 로고    scopus 로고
    • Zenith AAA endovascular graft: Intermediate-term results of the US multicenter trial
    • Greenberg RK, Chuter TA, Sternbergh WC, 3rd, Fearnot NE. Zenith AAA endovascular graft: intermediate-term results of the US multicenter trial. J Vasc Surg 2004;39:1209-18.
    • (2004) J Vasc Surg , vol.39 , pp. 1209-1218
    • Greenberg, R.K.1    Chuter, T.A.2    Sternbergh III, W.C.3    Fearnot, N.E.4
  • 49
    • 10744231613 scopus 로고    scopus 로고
    • A UK multi-centre experience with a second-generation endovascular stent-graft: Results from the Zenith Users Group
    • Hinchliffe RJ, Goldberg J, Macsweeney ST. A UK multi-centre experience with a second-generation endovascular stent-graft: results from the Zenith Users Group. Eur J Vasc Endovasc Surg 2004;27:51-5.
    • (2004) Eur J Vasc Endovasc Surg , vol.27 , pp. 51-55
    • Hinchliffe, R.J.1    Goldberg, J.2    Macsweeney, S.T.3
  • 52
    • 24944522371 scopus 로고    scopus 로고
    • Mid- and long-term device migration after endovascular abdominal aortic aneurysm repair: A comparison of AneuRx and Zenith endografts
    • discussion -1
    • Tonnessen BH, Sternbergh WC, 3rd, Money SR. Mid- and long-term device migration after endovascular abdominal aortic aneurysm repair: a comparison of AneuRx and Zenith endografts. J Vasc Surg 2005;42:392-400; discussion -1.
    • (2005) J Vasc Surg , vol.42 , pp. 392-400
    • Tonnessen, B.H.1    Sternbergh III, W.C.2    Money, S.R.3
  • 53
    • 45549083023 scopus 로고    scopus 로고
    • Outcomes following endovascular abdominal aortic aneurysm repair (EVAR): An anatomic and device-specific analysis
    • Abbruzzese TA, Kwolek CJ, Brewster DC, Chung TK, Kang J, Conrad MF et al. Outcomes following endovascular abdominal aortic aneurysm repair (EVAR): an anatomic and device-specific analysis. J Vasc Surg 2008;48:19-28.
    • (2008) J Vasc Surg , vol.48 , pp. 19-28
    • Abbruzzese, T.A.1    Kwolek, C.J.2    Brewster, D.C.3    Chung, T.K.4    Kang, J.5    Conrad, M.F.6
  • 55
    • 39149088019 scopus 로고    scopus 로고
    • Anaconda aortic stent-graft: Single-center experience of a new commercially available device for abdominal aortic aneurysms
    • Saratzis N, Melas N, Saratzis A, Lazarides J, Ktenidis K, Tsakiliotis S et al. Anaconda aortic stent-graft: single-center experience of a new commercially available device for abdominal aortic aneurysms. J Endovasc Ther 2008;15:33-41.
    • (2008) J Endovasc Ther , vol.15 , pp. 33-41
    • Saratzis, N.1    Melas, N.2    Saratzis, A.3    Lazarides, J.4    Ktenidis, K.5    Tsakiliotis, S.6
  • 58
    • 33745892887 scopus 로고    scopus 로고
    • Endovascular repair of abdominal aortic aneurysms in patients with severe angulation of the proximal neck using a flexible stent-graft: European Multicenter Experience
    • (Torino)
    • Albertini JN, Perdikides T, Soong CV, Hinchliffe RJ, Trojanowska M, Yusuf SW. Endovascular repair of abdominal aortic aneurysms in patients with severe angulation of the proximal neck using a flexible stent-graft: European Multicenter Experience. J Cardiovasc Surg (Torino) 2006;47:245-50.
    • (2006) J Cardiovasc Surg , vol.47 , pp. 245-250
    • Albertini, J.N.1    Perdikides, T.2    Soong, C.V.3    Hinchliffe, R.J.4    Trojanowska, M.5    Yusuf, S.W.6
  • 59
    • 71949109684 scopus 로고    scopus 로고
    • The Aorfix stent-graft to treat infrarenal abdominal aortic aneurysms with angulated necks and/or tortuous iliac arteries: Midterm results
    • Perdikides T, Georgiadis GS, Avgerinos ED, Fotis T, Verikokos C, Hopkinson BR et al. The Aorfix stent-graft to treat infrarenal abdominal aortic aneurysms with angulated necks and/or tortuous iliac arteries: midterm results. J Endovasc Ther 2009;16:567-76.
    • (2009) J Endovasc Ther , vol.16 , pp. 567-576
    • Perdikides, T.1    Georgiadis, G.S.2    Avgerinos, E.D.3    Fotis, T.4    Verikokos, C.5    Hopkinson, B.R.6
  • 60
    • 67650447406 scopus 로고    scopus 로고
    • Endurant stent-graft system: Preliminary report on an innovative treatment for challenging abdominal aortic aneurysm
    • (Torino)
    • Verhagen HJ, Torsello G, De Vries JP, et al. Endurant stent-graft system: preliminary report on an innovative treatment for challenging abdominal aortic aneurysm. J Cardiovasc Surg (Torino) 2009;50:153-8.
    • (2009) J Cardiovasc Surg , vol.50 , pp. 153-158
    • Verhagen, H.J.1    Torsello, G.2    De Vries, J.P.3
  • 61
    • 72249088986 scopus 로고    scopus 로고
    • Endovascular aortic aneurysm repair with the Endurant stent-graft: Early and 1-year results from a European multicenter experience
    • Torsello G, Troisi N, Tessarek J, Torsello GF, Dorigo W, Pulli R et al. Endovascular aortic aneurysm repair with the Endurant stent-graft: early and 1-year results from a European multicenter experience. J Vasc Interv Radiol 2010;21:73-80.
    • (2010) J Vasc Interv Radiol , vol.21 , pp. 73-80
    • Torsello, G.1    Troisi, N.2    Tessarek, J.3    Torsello, G.F.4    Dorigo, W.5    Pulli, R.6
  • 63
    • 71949104198 scopus 로고    scopus 로고
    • Initial experience with abdominal aneurysm repair using the E-vita abdominal stent-graft: A single-center study
    • Zipfel B, Buz S, Dusterhoft V, Hetzer R. Initial experience with abdominal aneurysm repair using the E-vita abdominal stent-graft: a single-center study. J Endovasc Ther 2009;16:577-89.
    • (2009) J Endovasc Ther , vol.16 , pp. 577-589
    • Zipfel, B.1    Buz, S.2    Dusterhoft, V.3    Hetzer, R.4
  • 64
    • 0033782683 scopus 로고    scopus 로고
    • Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: The EUROSTAR experience
    • European Collaborators on Stent/graft techniques for aortic aneurysm repair
    • Harris PL, Vallabhaneni SR, Desgranges P, Becquemin JP, van Marrewijk C, Laheij RJ. Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experience. European Collaborators on Stent/graft techniques for aortic aneurysm repair. J Vasc Surg 2000;32:739-49.
    • (2000) J Vasc Surg , vol.32 , pp. 739-749
    • Harris, P.L.1    Vallabhaneni, S.R.2    Desgranges, P.3    Becquemin, J.P.4    Van Marrewijk, C.5    Laheij, R.J.6
  • 65
    • 33846217702 scopus 로고    scopus 로고
    • Long-term results of endovascular abdominal aortic aneurysm treatment with the first generation of commercially available stent grafts
    • discussion 2
    • Leurs LJ, Buth J, Laheij RJ. Long-term results of endovascular abdominal aortic aneurysm treatment with the first generation of commercially available stent grafts. Arch Surg 2007;142:33-41; discussion 2.
    • (2007) Arch Surg , vol.142 , pp. 33-41
    • Leurs, L.J.1    Buth, J.2    Laheij, R.J.3
  • 66
    • 35148831711 scopus 로고    scopus 로고
    • Ten-year outcomes after endovascular aneurysm repair (EVAR) and magnitude of additional procedures
    • Väärämäki S, Pimenoff G, Heikkinen M, Suominen V, Saarinen J, Zeitlin R et al. Ten-year outcomes after endovascular aneurysm repair (EVAR) and magnitude of additional procedures. Scand J Surg 2007;96:221-8.
    • (2007) Scand J Surg , vol.96 , pp. 221-228
    • Väärämäki, S.1    Pimenoff, G.2    Heikkinen, M.3    Suominen, V.4    Saarinen, J.5    Zeitlin, R.6
  • 68
    • 0037280213 scopus 로고    scopus 로고
    • Mechanical failure of prosthetic human implants: A 10-year experience with aortic stent graft devices
    • Jacobs TS, Won J, Gravereaux EC, Faries PL, Morrissey N, Teodorescu VJ et al. Mechanical failure of prosthetic human implants: a 10-year experience with aortic stent graft devices. J Vasc Surg 2003;37:16-26.
    • (2003) J Vasc Surg , vol.37 , pp. 16-26
    • Jacobs, T.S.1    Won, J.2    Gravereaux, E.C.3    Faries, P.L.4    Morrissey, N.5    Teodorescu, V.J.6
  • 69
    • 0037600490 scopus 로고    scopus 로고
    • The endovascular repair of abdominal aortic aneurysm: An update analysis of structural failure modes of endovascular stent grafts
    • Jacobs T, Teodorescu V, Morrissey N, Carroccio A, Ellozy S, Minor M et al. The endovascular repair of abdominal aortic aneurysm: an update analysis of structural failure modes of endovascular stent grafts. Semin Vasc Surg 2003;16:103-12.
    • (2003) Semin Vasc Surg , vol.16 , pp. 103-112
    • Jacobs, T.1    Teodorescu, V.2    Morrissey, N.3    Carroccio, A.4    Ellozy, S.5    Minor, M.6
  • 70
    • 0029998672 scopus 로고    scopus 로고
    • Transfemoral endovascular repair of abdominal aortic aneurysm: Results of the North American EVT phase 1 trial
    • EVT Investigators
    • Moore WS, Rutherford RB. Transfemoral endovascular repair of abdominal aortic aneurysm: results of the North American EVT phase 1 trial. EVT Investigators. J Vasc Surg 1996;23:543-53.
    • (1996) J Vasc Surg , vol.23 , pp. 543-553
    • Moore, W.S.1    Rutherford, R.B.2
  • 71
    • 26944441282 scopus 로고    scopus 로고
    • Absence of proximal neck dilatation and graft migration after endovascular aneurysm repair with balloon-expandable stent-based endografts
    • Malas MB, Ohki T, Veith FJ, Chen T, Lipsitz EC, Shah AR et al. Absence of proximal neck dilatation and graft migration after endovascular aneurysm repair with balloon-expandable stent-based endografts. J Vasc Surg 2005;42:639-44.
    • (2005) J Vasc Surg , vol.42 , pp. 639-644
    • Malas, M.B.1    Ohki, T.2    Veith, F.J.3    Chen, T.4    Lipsitz, E.C.5    Shah, A.R.6
  • 72
    • 8844238411 scopus 로고    scopus 로고
    • Midterm results of the multicenter trial of the powerlink bifurcated system for endovascular aortic aneurysm repair
    • Carpenter JP. Midterm results of the multicenter trial of the powerlink bifurcated system for endovascular aortic aneurysm repair. J Vasc Surg 2004;40:849-59.
    • (2004) J Vasc Surg , vol.40 , pp. 849-859
    • Carpenter, J.P.1
  • 73
    • 70549094143 scopus 로고    scopus 로고
    • Endovascular stents for abdominal aortic aneurysms: A systematic review and economic model
    • 215-318, iii
    • Chambers D, Epstein D, Walker S, Fayter D, Paton F, Wright K et al. Endovascular stents for abdominal aortic aneurysms: a systematic review and economic model. Health Technol Assess 2009;13:1-189, 215-318, iii.
    • (2009) Health Technol Assess , vol.13 , pp. 1-189
    • Chambers, D.1    Epstein, D.2    Walker, S.3    Fayter, D.4    Paton, F.5    Wright, K.6
  • 74
    • 33646147568 scopus 로고    scopus 로고
    • Secondary interventions following endovascular abdominal aortic aneurysm repair using current endografts. A EUROSTAR report
    • Hobo R, Buth J. Secondary interventions following endovascular abdominal aortic aneurysm repair using current endografts. A EUROSTAR report. J Vasc Surg 2006;43:896-902.
    • (2006) J Vasc Surg , vol.43 , pp. 896-902
    • Hobo, R.1    Buth, J.2
  • 75
    • 12144263199 scopus 로고    scopus 로고
    • Endovascular repair of abdominal aortic aneurysms using 3 commercially available devices: Midterm results
    • Aburahma AF, Stone PA, Bates MC, Khan TN, Prigozen JM, Welch CA. Endovascular repair of abdominal aortic aneurysms using 3 commercially available devices: midterm results. J Endovasc Ther 2004;11:641-8.
    • (2004) J Endovasc Ther , vol.11 , pp. 641-648
    • Aburahma, A.F.1    Stone, P.A.2    Bates, M.C.3    Khan, T.N.4    Prigozen, J.M.5    Welch, C.A.6
  • 76
    • 16244405241 scopus 로고    scopus 로고
    • Midterm results of a single-center experience with commercially available devices for endovascular aneurysm repair
    • Biebl M, Hakaim AG, Oldenburg WA, Lau LL, Klocker J, Neuhauser B et al. Midterm results of a single-center experience with commercially available devices for endovascular aneurysm repair. Mt Sinai J Med 2005;72:127-35.
    • (2005) Mt Sinai J Med , vol.72 , pp. 127-135
    • Biebl, M.1    Hakaim, A.G.2    Oldenburg, W.A.3    Lau, L.L.4    Klocker, J.5    Neuhauser, B.6
  • 77
    • 13244266907 scopus 로고    scopus 로고
    • Is neck dilatation after endovascular aneurysm repair graft dependent? Results of 4 US Phase II trials
    • Dillavou ED, Muluk S, Makaroun MS. Is neck dilatation after endovascular aneurysm repair graft dependent? Results of 4 US Phase II trials. Vasc Endovascular Surg 2005;39:47-54.
    • (2005) Vasc Endovascular Surg , vol.39 , pp. 47-54
    • Dillavou, E.D.1    Muluk, S.2    Makaroun, M.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.