메뉴 건너뛰기




Volumn 38, Issue 5, 2010, Pages 1596-1604

Real-time imaging and detection of intracranial haemorrhage by electrical impedance tomography in a piglet model

Author keywords

Electrical impedance tomography; Image monitoring; Intracranial haemorrhage

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; BRAIN HEMORRHAGE; COMPUTER ASSISTED IMPEDANCE TOMOGRAPHY; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; EARLY DIAGNOSIS; ELECTRODE; IMAGE ANALYSIS; IMAGE QUALITY; NONHUMAN; PIGLET; VALIDITY;

EID: 78449309610     PISSN: 03000605     EISSN: None     Source Type: Journal    
DOI: 10.1177/147323001003800504     Document Type: Article
Times cited : (50)

References (22)
  • 1
    • 0026045255 scopus 로고
    • Delayed traumatic intracerebral hematoma
    • Mertol T, Guner M, Acar U, et al: Delayed traumatic intracerebral hematoma. Br J Neurosurg 1991; 5: 491-498.
    • (1991) Br J Neurosurg , vol.5 , pp. 491-498
    • Mertol, T.1    Guner, M.2    Acar, U.3
  • 2
    • 0021978464 scopus 로고
    • Postoperative intracerebral hemorrhages: A survey of computed tomographic findings after 1074 intracranial operations
    • Fukamachi A, Koizumi H, Nukui H: Postoperative intracerebral hemorrhages: a survey of computed tomographic findings after 1074 intracranial operations. Surg Neurol 1985; 23: 575-580.
    • (1985) Surg Neurol , vol.23 , pp. 575-580
    • Fukamachi, A.1    Koizumi, H.2
  • 3
    • 0022875870 scopus 로고
    • Postoperativeextraduralhematomas: Computed tomographic survey of1105 intracranial operations
    • Fukamachi A, Koizumi H, Nagaseki Y, et al: Postoperativeextraduralhematomas: computed tomographic survey of1105 intracranial operations. Neurosurgery 1986; 19: 1603 589-593.
    • (1986) Neurosurgery , vol.19 , Issue.1603 , pp. 589-593
    • Fukamachi, A.1    Koizumi, H.2    Nagaseki, Y.3
  • 4
    • 0023687473 scopus 로고
    • Postoperative hemorrhage: A survey of 4992 intracranial procedures
    • Kalfas IH, Little JR: Postoperative hemorrhage: a survey of 4992 intracranial procedures. Neurosurgery 1988; 23: 343-347.
    • (1988) Neurosurgery , vol.23 , pp. 343-347
    • Kalfas, I.H.1    Little, J.R.2
  • 5
    • 78149338957 scopus 로고    scopus 로고
    • The clinical significance and optimal timing of postoperative computed tomography following cranial surgery
    • Epub 1-5, DOI: 10.3171/2009.11.JNS081048
    • Khaldi A, Prabhu VC, Anderson DE, et al: The clinical significance and optimal timing of postoperative computed tomography following cranial surgery. J Neurosug 2009; Epub 1-5 (DOI: 10.3171/2009.11.JNS081048).
    • (2009) J Neurosug
    • Khaldi, A.1    Prabhu, V.C.2    Anderson, D.E.3
  • 6
    • 0031280166 scopus 로고    scopus 로고
    • Image with electricity: Report of the European Concerted Action on Impedance Tomography
    • Boone K, Barber D, Brown B: Image with electricity: report of the European Concerted Action on Impedance Tomography. J Med Eng Technol 1997; 21: 201-232.
    • (1997) J Med Eng Technol , vol.21 , pp. 201-232
    • Boone, K.1    Barber, D.2    Brown, B.3
  • 7
    • 9444222494 scopus 로고    scopus 로고
    • Impedance pharyngography to assess swallowing function
    • Kusuhara T, Nakamura T, Shirakawa Y, et al: Impedance pharyngography to assess swallowing function. J Int Med Res 2004; 32: 608-616.
    • (2004) J Int Med Res , vol.32 , pp. 608-616
    • Kusuhara, T.1    Nakamura, T.2    Shirakawa, Y.3
  • 8
    • 0024239363 scopus 로고
    • Some possible neurological applications of applied potential tomography
    • Holder D, Gardner-Medwin AR: Some possible neurological applications of applied potential tomography. Clin Phys Physiol Meas 1988; 9(suppl A): 111-119.
    • (1988) Clin Phys Physiol Meas , vol.9 , Issue.SUPPL. A , pp. 111-119
    • Holder, D.1    Gardner-Medwin, A.R.2
  • 9
    • 34447108195 scopus 로고    scopus 로고
    • Use of statistical parametric mapping (SPM) to enhance electrical impedance tomography (EIT) image sets
    • Yerworth RJ, Zhang Y, Tidswell T, et al: Use of statistical parametric mapping (SPM) to enhance electrical impedance tomography (EIT) image sets. Physiol Meas 2007; 28: S141-S151.
    • (2007) Physiol Meas , vol.28
    • Yerworth, R.J.1    Zhang, Y.2    Tidswell, T.3
  • 10
    • 67349229831 scopus 로고    scopus 로고
    • Impedance changes recorded with scalp electrodes during visual evoked responses: Implications for electrical impedance tomography of fast neural activity
    • Gilad O, Holder DS: Impedance changes recorded with scalp electrodes during visual evoked responses: implications for electrical impedance tomography of fast neural activity. Neuroimage 2009; 47: 514-522.
    • (2009) Neuroimage , vol.47 , pp. 514-522
    • Gilad, O.1    Holder, D.S.2
  • 12
    • 38949215043 scopus 로고    scopus 로고
    • Image monitoring for an intraperitoneal bleeding model of pigs using electrical impedance tomography
    • Wanjun S, Fusheng Y, Wei Z, et al: Image monitoring for an intraperitoneal bleeding model of pigs using electrical impedance tomography. Physiol Meas 2008; 29: 217-225.
    • (2008) Physiol Meas , vol.29 , pp. 217-225
    • Wanjun, S.1    Fusheng, Y.2    Wei, Z.3
  • 13
    • 70349673096 scopus 로고    scopus 로고
    • Application of electrical impedance tomography for continuous monitoring of retroperitoneal bleeding after blunt trauma
    • Shuai W, You F, Zhang H, et al: Application of electrical impedance tomography for continuous monitoring of retroperitoneal bleeding after blunt trauma. Ann Biomed Eng 2009; 37: 2373-2379.
    • (2009) Ann Biomed Eng , vol.37 , pp. 2373-2379
    • Shuai, W.1    You, F.2    Zhang, H.3
  • 14
    • 0029897777 scopus 로고    scopus 로고
    • Lobar intracerebral hemorrhage model in pigs: Rapid edema development in perihematomal white matter
    • Wagner KR, Xi G, Hua Y, et al: Lobar intracerebral hemorrhage model in pigs: rapid edema development in perihematomal white matter. Stroke 1996; 27: 490-497.
    • (1996) Stroke , vol.27 , pp. 490-497
    • Wagner, K.R.1    Xi, G.2    Hua, Y.3
  • 17
    • 0028337782 scopus 로고
    • Image reconstruction using non-adjacent drive configurations (electric impedance tomography)
    • Avis NJ, Barber DC: Image reconstruction using non-adjacent drive configurations (electric impedance tomography). Physiol Meas 1994; 15(suppl 2A): A153-A160.
    • (1994) Physiol Meas , vol.15 , Issue.SUPPL. 2A
    • Avis, N.J.1    Barber, D.C.2
  • 18
    • 0016391336 scopus 로고
    • Assessment of coma and impaired consciousness. A practical scale
    • Teasdale G, Jennett B: Assessment of coma and impaired consciousness. A practical scale. Lancet 1974; 304: 81-84.
    • (1974) Lancet , vol.304 , pp. 81-84
    • Teasdale, G.1    Jennett, B.2
  • 19
    • 0036123293 scopus 로고    scopus 로고
    • Progressive hemorrhage after head trauma: Predictors and consequences of the evolving injury
    • Oertel M, Kelly DF, McArthur D, et al: Progressive hemorrhage after head trauma: predictors and consequences of the evolving injury. J Neurosurg 2002; 96: 109-116.
    • (2002) J Neurosurg , vol.96 , pp. 109-116
    • Oertel, M.1    Kelly, D.F.2    McArthur, D.3
  • 20
    • 79955678393 scopus 로고    scopus 로고
    • Early CT signs of progressive hemorrhagic injury following acute traumatic brain injury
    • Feb 4 (Epub, DOI: 10.1007/s00234010-0659-8
    • Tong WS, Zheng P, Xu JF, et al: Early CT signs of progressive hemorrhagic injury following acute traumatic brain injury. Neuroradiology 2010; Feb 4 (Epub) (DOI: 10.1007/s00234010-0659-8).
    • (2010) Neuroradiology
    • Tong, W.S.1    Zheng, P.2    Xu, J.F.3
  • 21
    • 70149113909 scopus 로고    scopus 로고
    • GREIT: A unified approach to 2D linear EIT reconstruction of lung images
    • Adler A, Arnold JH, Bayford R, et al: GREIT: a unified approach to 2D linear EIT reconstruction of lung images. Physiol Meas 2009; 30: S35-S55.
    • (2009) Physiol Meas , vol.30
    • Adler, A.1    Arnold, J.H.2    Bayford, R.3
  • 22
    • 45749130657 scopus 로고    scopus 로고
    • Fuzzy modeling of electrical impedance tomography images of the lungs
    • Tanaka H, Ortega NR, Galizia MS, et al: Fuzzy modeling of electrical impedance tomography images of the lungs. Clinics (Sao Paulo) 2008; 63: 363-370.
    • (2008) Clinics (Sao Paulo) , vol.63 , pp. 363-370
    • Tanaka, H.1    Ortega, N.R.2    Galizia, M.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.